Environmental and Ambient Vibration Monitoring of Historical Adobe Buildings: Applications in Emblematic Andean Churches

Descripción del Articulo

This paper presents the application of long-term environmental and structural remote monitoring in two emblematic 16th-century adobe churches located in southern Peru. The paper starts by presenting details of the planning and installation processes of the monitoring systems and continues with a det...

Descripción completa

Detalles Bibliográficos
Autores: Zonno G., Aguilar R., Boroschek R., Lourenço P.B.
Formato: artículo
Fecha de Publicación:2019
Institución:Consejo Nacional de Ciencia Tecnología e Innovación
Repositorio:CONCYTEC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.concytec.gob.pe:20.500.12390/2757
Enlace del recurso:https://hdl.handle.net/20.500.12390/2757
https://doi.org/10.1080/15583058.2019.1653402
Nivel de acceso:acceso abierto
Materia:structural monitoring
Adobe buildings
Andean churches
correlation analysis
environmental monitoring
http://purl.org/pe-repo/ocde/ford#5.07.01
Descripción
Sumario:This paper presents the application of long-term environmental and structural remote monitoring in two emblematic 16th-century adobe churches located in southern Peru. The paper starts by presenting details of the planning and installation processes of the monitoring systems and continues with a detailed discussion of the results of almost two years of continuous monitoring. As expected, due to the large thermal inertia of the adobe systems and size of the buildings, the results of the environmental monitoring indicated a non-uniform distribution of temperature and relative humidity inside the buildings, and an important attenuation of the internal conditions in comparison with the external ones. On the other hand, the structural monitoring results evidenced an annual cyclical behavior of the natural frequencies with an apparent correspondence with the changes in environmental conditions due to seasonal influences. The correlation of ambient conditions and structural parameters confirmed the high affinity between relative humidity measurements and natural frequencies when hourly fluctuations were removed from the measurements. An important novelty is the affinity of structural dynamic properties and a single environmental variable, the absolute humidity, was also evidenced since high determination coefficients were obtained when it was compared with the identified natural frequencies. © 2019, © 2019 Taylor & Francis.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).