Analysis of the long and short-term effects of temperature and humidity on the structural properties of adobe buildings using continuous monitoring
Descripción del Articulo
The analysis of the evolution of modal properties and its relationship with changes in environmental properties (i.e. ambient temperature and relative humidity) is of high importance since their effects along time can mask the influence of structural damage. While structural monitoring studies to as...
Autores: | , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Consejo Nacional de Ciencia Tecnología e Innovación |
Repositorio: | CONCYTEC-Institucional |
Lenguaje: | inglés |
OAI Identifier: | oai:repositorio.concytec.gob.pe:20.500.12390/513 |
Enlace del recurso: | https://hdl.handle.net/20.500.12390/513 https://doi.org/10.1016/j.engstruct.2019.109299 |
Nivel de acceso: | acceso abierto |
Materia: | Temperature Modal analysis Monitoring Religious buildings Structural analysis Ambient vibration monitoring Environmental conditions Environmental correlations Environmental Monitoring https://purl.org/pe-repo/ocde/ford#2.00.00 |
Sumario: | The analysis of the evolution of modal properties and its relationship with changes in environmental properties (i.e. ambient temperature and relative humidity) is of high importance since their effects along time can mask the influence of structural damage. While structural monitoring studies to assess the relationship between modal parameters and environmental conditions are abundantly available for modern materials constructions (i.e. concrete or steel), very few studies are reported for adobe buildings. The present paper focuses on the study of the short and long-term structural behavior of existing adobe buildings through the long-term monitoring of ambient vibration and environmental conditions. With this purpose, the paper describes in detail the case study of the San Pedro Apostol Church of Andahuaylillas located in Cusco, inside the Andean region of Peru, a 16th-century church considered as a masterpiece of South American baroque architecture. The paper starts with a historical, architectural, and structural description of the case study. Then, it describes the implementation of a long-term monitoring system of ambient vibration and environmental variables, as well as the results of almost one year of continuous monitoring process. Finally, the obtained results of natural frequencies are correlated with ambient parameters, demonstrating different timescale influences in the modal properties due to daily and seasonal variations of the environmental conditions. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).