Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning

Descripción del Articulo

This study aims to evaluate and compare each other, surface-active additives on the inhibition and control of acid mist, as well as different control parameters and operation of the copper electrowinning process, such as surface tension electrolyte effect on current efficiency, energy consumption an...

Descripción completa

Detalles Bibliográficos
Autores: Vargas, C., Navarro, P.
Formato: artículo
Fecha de Publicación:2010
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revista UNMSM - IIGEO
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/434
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/434
Nivel de acceso:acceso abierto
Materia:Copper
additives
surfactants
electrowinnig
acid mist
cobre
aditivos
surfactantes
electroobtención
neblina ácida
id 1682-3087_32c8c383856e966b83c4632f9f3449d4
oai_identifier_str oai:ojs.csi.unmsm:article/434
network_acronym_str 1682-3087
network_name_str Revista UNMSM - IIGEO
dc.title.none.fl_str_mv Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
Aspectos preliminares de la evaluación y efecto de aditivos surfactantes en el proceso de electro obtención de cobre
title Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
spellingShingle Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
Vargas, C.
Copper
additives
surfactants
electrowinnig
acid mist
cobre
aditivos
surfactantes
electroobtención
neblina ácida
title_short Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
title_full Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
title_fullStr Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
title_full_unstemmed Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
title_sort Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinning
dc.creator.none.fl_str_mv Vargas, C.
Navarro, P.
author Vargas, C.
author_facet Vargas, C.
Navarro, P.
author_role author
author2 Navarro, P.
author2_role author
dc.subject.none.fl_str_mv Copper
additives
surfactants
electrowinnig
acid mist
cobre
aditivos
surfactantes
electroobtención
neblina ácida
topic Copper
additives
surfactants
electrowinnig
acid mist
cobre
aditivos
surfactantes
electroobtención
neblina ácida
dc.description.none.fl_txt_mv This study aims to evaluate and compare each other, surface-active additives on the inhibition and control of acid mist, as well as different control parameters and operation of the copper electrowinning process, such as surface tension electrolyte effect on current efficiency, energy consumption and cathode quality. The results obtained confirm that the commercial additive Fluoride FC-1100 is an excellent surfactant, and that low doses drastically reduced the surface tension of electrolyte (from 75 dynes / cm to 55 dynes / cm) and therefore allows to reduce acid emissions without interfere with other process parameters such as current efficiency, energy consumption or cathodic quality deposits and obtaining good adhesion. This is not the case of Genapol PF-10, drastically reduces the surface tension and hence the mist generation but shows a detrimental effect on the current efficiency due to low quality cathodic, because the deposits obtained are rugged, rigid and low adhesion; thus it´s not an alternative surfactant. Another is the case Flotanol C-7, the behavior of this reagent is optimal because it reduces the surface tension close to the optimum levels required, thus inhibits the generation of acid mist in electrowinning cell without adversely affecting other parameters process as current efficiency, energy consumption or cathodic quality, obtaining cathodes of high quality, smooth and with good adhesion.
El presente trabajo tiene como objetivo la evaluación y comparación entre sí, de aditivos tenso-activos en la inhibición y control de la neblina ácida, así como también en diferentes parámetros de control y operación del proceso de electroobtención de cobre, tales como tensión superficial del electrolito, efecto sobre la eficiencia de corriente, consumo energético y calidad catódica. Los resultados obtenidos comprueban que el aditivo comercial Fluorad FC-1100 es un excelente surfactante, ya que en bajas dosis disminuye drásticamente la tensión superficial del electrolito (desde75 dinas/cm hasta 55 dinas/cm) y en consecuencia logra disminuir las emisiones ácidas, sin perjudicar otros parámetros del proceso como la eficiencia de corriente, el consumo energético o la calidad catódica obteniendo depósitos lisos y de buena adherencia. Este no es el caso de Genapol PF-10 ya que, pese a disminuir drásticamente la tensión superficial y en consecuencia la generación de neblina, muestra un efecto perjudicial en la eficiencia de corriente debido a su baja calidad catódica, ya que se obtienen depósitos rugosos, rígidos y de mala adherencia por lo tanto no es un surfactante alternativo. Otro es el caso de Flotanol C-7, el comportamiento de este reactivo es óptimo ya que disminuye la tensión superficial en niveles cercanos al óptimo requerido, en consecuencia inhibe la generación de neblina ácida en la celda de electroobtención, sin afectar perjudicialmente otros parámetros del proceso como la eficiencia de corriente, el consumo energético o la calidad catódica obteniendo cátodos de excelente calidad, lisos y de buena adherencia.
description This study aims to evaluate and compare each other, surface-active additives on the inhibition and control of acid mist, as well as different control parameters and operation of the copper electrowinning process, such as surface tension electrolyte effect on current efficiency, energy consumption and cathode quality. The results obtained confirm that the commercial additive Fluoride FC-1100 is an excellent surfactant, and that low doses drastically reduced the surface tension of electrolyte (from 75 dynes / cm to 55 dynes / cm) and therefore allows to reduce acid emissions without interfere with other process parameters such as current efficiency, energy consumption or cathodic quality deposits and obtaining good adhesion. This is not the case of Genapol PF-10, drastically reduces the surface tension and hence the mist generation but shows a detrimental effect on the current efficiency due to low quality cathodic, because the deposits obtained are rugged, rigid and low adhesion; thus it´s not an alternative surfactant. Another is the case Flotanol C-7, the behavior of this reagent is optimal because it reduces the surface tension close to the optimum levels required, thus inhibits the generation of acid mist in electrowinning cell without adversely affecting other parameters process as current efficiency, energy consumption or cathodic quality, obtaining cathodes of high quality, smooth and with good adhesion.
publishDate 2010
dc.date.none.fl_str_mv 2010-12-15
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/434
10.15381/iigeo.v13i26.434
url https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/434
identifier_str_mv 10.15381/iigeo.v13i26.434
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/434/373
dc.rights.none.fl_str_mv Derechos de autor 2010 C. Vargas, P. Navarro
http://creativecommons.org/licenses/by-nc-sa/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2010 C. Vargas, P. Navarro
http://creativecommons.org/licenses/by-nc-sa/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica
publisher.none.fl_str_mv Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica
dc.source.none.fl_str_mv Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 13 No 26 (2010); 85-90
Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 13 Núm. 26 (2010); 85-90
1682-3087
1561-0888
reponame:Revista UNMSM - IIGEO
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
reponame_str Revista UNMSM - IIGEO
collection Revista UNMSM - IIGEO
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1684466177813774336
spelling Preliminary aspects of the evaluation and effect of surfactant additives in the process copper electrowinningAspectos preliminares de la evaluación y efecto de aditivos surfactantes en el proceso de electro obtención de cobreVargas, C.Navarro, P.Copperadditivessurfactantselectrowinnigacid mistcobreaditivossurfactanteselectroobtenciónneblina ácidaThis study aims to evaluate and compare each other, surface-active additives on the inhibition and control of acid mist, as well as different control parameters and operation of the copper electrowinning process, such as surface tension electrolyte effect on current efficiency, energy consumption and cathode quality. The results obtained confirm that the commercial additive Fluoride FC-1100 is an excellent surfactant, and that low doses drastically reduced the surface tension of electrolyte (from 75 dynes / cm to 55 dynes / cm) and therefore allows to reduce acid emissions without interfere with other process parameters such as current efficiency, energy consumption or cathodic quality deposits and obtaining good adhesion. This is not the case of Genapol PF-10, drastically reduces the surface tension and hence the mist generation but shows a detrimental effect on the current efficiency due to low quality cathodic, because the deposits obtained are rugged, rigid and low adhesion; thus it´s not an alternative surfactant. Another is the case Flotanol C-7, the behavior of this reagent is optimal because it reduces the surface tension close to the optimum levels required, thus inhibits the generation of acid mist in electrowinning cell without adversely affecting other parameters process as current efficiency, energy consumption or cathodic quality, obtaining cathodes of high quality, smooth and with good adhesion.El presente trabajo tiene como objetivo la evaluación y comparación entre sí, de aditivos tenso-activos en la inhibición y control de la neblina ácida, así como también en diferentes parámetros de control y operación del proceso de electroobtención de cobre, tales como tensión superficial del electrolito, efecto sobre la eficiencia de corriente, consumo energético y calidad catódica. Los resultados obtenidos comprueban que el aditivo comercial Fluorad FC-1100 es un excelente surfactante, ya que en bajas dosis disminuye drásticamente la tensión superficial del electrolito (desde75 dinas/cm hasta 55 dinas/cm) y en consecuencia logra disminuir las emisiones ácidas, sin perjudicar otros parámetros del proceso como la eficiencia de corriente, el consumo energético o la calidad catódica obteniendo depósitos lisos y de buena adherencia. Este no es el caso de Genapol PF-10 ya que, pese a disminuir drásticamente la tensión superficial y en consecuencia la generación de neblina, muestra un efecto perjudicial en la eficiencia de corriente debido a su baja calidad catódica, ya que se obtienen depósitos rugosos, rígidos y de mala adherencia por lo tanto no es un surfactante alternativo. Otro es el caso de Flotanol C-7, el comportamiento de este reactivo es óptimo ya que disminuye la tensión superficial en niveles cercanos al óptimo requerido, en consecuencia inhibe la generación de neblina ácida en la celda de electroobtención, sin afectar perjudicialmente otros parámetros del proceso como la eficiencia de corriente, el consumo energético o la calidad catódica obteniendo cátodos de excelente calidad, lisos y de buena adherencia.Facultad de Ingeniería Geológica, Minera, Metalurgica y Geográfica2010-12-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/43410.15381/iigeo.v13i26.434Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol 13 No 26 (2010); 85-90Revista del Instituto de Investigación de la Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica; Vol. 13 Núm. 26 (2010); 85-901682-30871561-0888reponame:Revista UNMSM - IIGEOinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/434/373Derechos de autor 2010 C. Vargas, P. Navarrohttp://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccess2020-06-30T18:25:13Zmail@mail.com -
score 13.881255
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).