Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos
Descripción del Articulo
Silos are vulnerable structures during severe seismic events due to their slenderness and their interaction with stored material. This investigation presents the results of a special structure that incorporates a basal seismic isolation system, such as the Triple Friction Pendulum System (TFPS). A p...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2025 |
| Institución: | Universidad Peruana de Ciencias Aplicadas |
| Repositorio: | UPC-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorioacademico.upc.edu.pe:10757/687165 |
| Enlace del recurso: | https://doi.org/10.11159/iccste25.163 http://hdl.handle.net/10757/687165 |
| Nivel de acceso: | acceso abierto |
| Materia: | isolators reinforced concrete silos slenderness ratio stored material-structure interaction https://purl.org/pe-repo/ocde/ford#2.01.01 |
| id |
UUPC_c10cd09d75b0ad52f43646389f49a9ac |
|---|---|
| oai_identifier_str |
oai:repositorioacademico.upc.edu.pe:10757/687165 |
| network_acronym_str |
UUPC |
| network_name_str |
UPC-Institucional |
| repository_id_str |
2670 |
| dc.title.es_PE.fl_str_mv |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos |
| title |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos |
| spellingShingle |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos Portal, Piero H. isolators reinforced concrete silos slenderness ratio stored material-structure interaction https://purl.org/pe-repo/ocde/ford#2.01.01 |
| title_short |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos |
| title_full |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos |
| title_fullStr |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos |
| title_full_unstemmed |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos |
| title_sort |
Parametric Seismic Response of Base-Isolated Reinforced Concrete Silos |
| author |
Portal, Piero H. |
| author_facet |
Portal, Piero H. Fernandez-Davila, Victor I. |
| author_role |
author |
| author2 |
Fernandez-Davila, Victor I. |
| author2_role |
author |
| dc.contributor.author.fl_str_mv |
Portal, Piero H. Fernandez-Davila, Victor I. |
| dc.subject.es_PE.fl_str_mv |
isolators reinforced concrete silos slenderness ratio stored material-structure interaction |
| topic |
isolators reinforced concrete silos slenderness ratio stored material-structure interaction https://purl.org/pe-repo/ocde/ford#2.01.01 |
| dc.subject.ocde.es_PE.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.01.01 |
| description |
Silos are vulnerable structures during severe seismic events due to their slenderness and their interaction with stored material. This investigation presents the results of a special structure that incorporates a basal seismic isolation system, such as the Triple Friction Pendulum System (TFPS). A parametric study was conducted on eight models of reinforced concrete silos to evaluate the effectiveness of TFPS isolators in mitigating the effects of various parameters on their seismic response. This research makes significant contributions by identifying parameters that affect isolated silos, providing valuable insights into their seismic behaviour. The silos were modeled and validated by comparing the forces obtained from a modal spectral analysis with analytical forces from a previous study, achieving acceptable errors for the research objectives. Finally, a nonlinear dynamic time history analysis was performed using seven seismic records, selecting one as critical due to its peak acceleration at the start. The study determined that TFPS isolators efficiently reduced the influence of the analyzed parameters in slender silos, allowing their omission in non-critical seismic events for isolated structures. Compact silos exhibited reduced effectiveness due to uplift related to their compact design and the interaction between the stored material and the structure. This necessitates a thorough evaluation of the analysed parameters. In critical case, the full slender silo exhibited no increase in seismic response due to the stiffness contribution of the stored material. Conversely, empty slender silos showed increases because the force transfer in the final Phase of TFPS isolators became critical without the stiffness contribution of the stored material. Compact silos exhibited a similar seismic response for non-critical earthquakes, but the response was amplified due to significant lateral displacements. |
| publishDate |
2025 |
| dc.date.accessioned.none.fl_str_mv |
2025-11-15T00:09:11Z |
| dc.date.available.none.fl_str_mv |
2025-11-15T00:09:11Z |
| dc.date.issued.fl_str_mv |
2025-01-01 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.version.none.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a2411 |
| format |
article |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.11159/iccste25.163 |
| dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/10757/687165 |
| dc.identifier.eissn.none.fl_str_mv |
23693002 |
| dc.identifier.journal.es_PE.fl_str_mv |
International Conference on Civil Structural and Transportation Engineering |
| dc.identifier.eid.none.fl_str_mv |
2-s2.0-105012168849 |
| dc.identifier.scopusid.none.fl_str_mv |
SCOPUS_ID:105012168849 |
| dc.identifier.isni.none.fl_str_mv |
0000 0001 2196 144X |
| url |
https://doi.org/10.11159/iccste25.163 http://hdl.handle.net/10757/687165 |
| identifier_str_mv |
23693002 International Conference on Civil Structural and Transportation Engineering 2-s2.0-105012168849 SCOPUS_ID:105012168849 0000 0001 2196 144X |
| dc.language.iso.es_PE.fl_str_mv |
eng |
| language |
eng |
| dc.rights.*.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.*.fl_str_mv |
http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by/4.0/ |
| dc.format.es_PE.fl_str_mv |
application/pdf |
| dc.publisher.es_PE.fl_str_mv |
Avestia Publishing |
| dc.source.none.fl_str_mv |
reponame:UPC-Institucional instname:Universidad Peruana de Ciencias Aplicadas instacron:UPC |
| instname_str |
Universidad Peruana de Ciencias Aplicadas |
| instacron_str |
UPC |
| institution |
UPC |
| reponame_str |
UPC-Institucional |
| collection |
UPC-Institucional |
| dc.source.journaltitle.none.fl_str_mv |
International Conference on Civil Structural and Transportation Engineering |
| bitstream.url.fl_str_mv |
https://repositorioacademico.upc.edu.pe/bitstream/10757/687165/3/license.txt https://repositorioacademico.upc.edu.pe/bitstream/10757/687165/2/license_rdf https://repositorioacademico.upc.edu.pe/bitstream/10757/687165/1/ICCSTE_163.pdf |
| bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 0175ea4a2d4caec4bbcc37e300941108 2a67ad855ef28c20971c60e73d0e14a9 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Académico UPC |
| repository.mail.fl_str_mv |
upc@openrepository.com |
| _version_ |
1865096811529633792 |
| spelling |
d3c12ff5b163aafc20d41646cfca4dfe300b5f5f4d145c6c7b064accadbd64e1331Portal, Piero H.Fernandez-Davila, Victor I.2025-11-15T00:09:11Z2025-11-15T00:09:11Z2025-01-01https://doi.org/10.11159/iccste25.163http://hdl.handle.net/10757/68716523693002International Conference on Civil Structural and Transportation Engineering2-s2.0-105012168849SCOPUS_ID:1050121688490000 0001 2196 144XSilos are vulnerable structures during severe seismic events due to their slenderness and their interaction with stored material. This investigation presents the results of a special structure that incorporates a basal seismic isolation system, such as the Triple Friction Pendulum System (TFPS). A parametric study was conducted on eight models of reinforced concrete silos to evaluate the effectiveness of TFPS isolators in mitigating the effects of various parameters on their seismic response. This research makes significant contributions by identifying parameters that affect isolated silos, providing valuable insights into their seismic behaviour. The silos were modeled and validated by comparing the forces obtained from a modal spectral analysis with analytical forces from a previous study, achieving acceptable errors for the research objectives. Finally, a nonlinear dynamic time history analysis was performed using seven seismic records, selecting one as critical due to its peak acceleration at the start. The study determined that TFPS isolators efficiently reduced the influence of the analyzed parameters in slender silos, allowing their omission in non-critical seismic events for isolated structures. Compact silos exhibited reduced effectiveness due to uplift related to their compact design and the interaction between the stored material and the structure. This necessitates a thorough evaluation of the analysed parameters. In critical case, the full slender silo exhibited no increase in seismic response due to the stiffness contribution of the stored material. Conversely, empty slender silos showed increases because the force transfer in the final Phase of TFPS isolators became critical without the stiffness contribution of the stored material. Compact silos exhibited a similar seismic response for non-critical earthquakes, but the response was amplified due to significant lateral displacements.ODS 9: Industria, innovación e infraestructuraODS 3: Salud y bienestarODS 4: Educación de calidadapplication/pdfengAvestia Publishinginfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/isolatorsreinforced concretesilosslenderness ratiostored material-structure interactionhttps://purl.org/pe-repo/ocde/ford#2.01.01Parametric Seismic Response of Base-Isolated Reinforced Concrete Silosinfo:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a2411International Conference on Civil Structural and Transportation Engineeringreponame:UPC-Institucionalinstname:Universidad Peruana de Ciencias Aplicadasinstacron:UPC2025-11-15T00:09:13ZLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorioacademico.upc.edu.pe/bitstream/10757/687165/3/license.txt8a4605be74aa9ea9d79846c1fba20a33MD53falseCC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-8908https://repositorioacademico.upc.edu.pe/bitstream/10757/687165/2/license_rdf0175ea4a2d4caec4bbcc37e300941108MD52falseORIGINALICCSTE_163.pdfICCSTE_163.pdfapplication/pdf749240https://repositorioacademico.upc.edu.pe/bitstream/10757/687165/1/ICCSTE_163.pdf2a67ad855ef28c20971c60e73d0e14a9MD51true10757/687165oai:repositorioacademico.upc.edu.pe:10757/6871652026-03-20 00:21:47.059Repositorio Académico UPCupc@openrepository.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 |
| score |
13.920589 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).