Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil
Descripción del Articulo
In most structural analyzes, Soil-Structure Interaction (SSI) is excluded, and it has been shown that SSI affects it depending on the type of structure and soil properties. Therefore, in this article, the structural response of an isolated system was analyzed, including the flexibility of the soil i...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2024 |
| Institución: | Universidad Peruana de Ciencias Aplicadas |
| Repositorio: | UPC-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorioacademico.upc.edu.pe:10757/675702 |
| Enlace del recurso: | https://doi.org/10.1063/5.0194856 http://hdl.handle.net/10757/675702 |
| Nivel de acceso: | acceso abierto |
| Materia: | moderately rigid soil https://purl.org/pe-repo/ocde/ford#3.00.00 |
| id |
UUPC_6070e3f8c87c8bfdb89b9bc88c968e58 |
|---|---|
| oai_identifier_str |
oai:repositorioacademico.upc.edu.pe:10757/675702 |
| network_acronym_str |
UUPC |
| network_name_str |
UPC-Institucional |
| repository_id_str |
2670 |
| dc.title.es_PE.fl_str_mv |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil |
| title |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil |
| spellingShingle |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil Paredes, Briayan Rojas moderately rigid soil https://purl.org/pe-repo/ocde/ford#3.00.00 |
| title_short |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil |
| title_full |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil |
| title_fullStr |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil |
| title_full_unstemmed |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil |
| title_sort |
Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soil |
| author |
Paredes, Briayan Rojas |
| author_facet |
Paredes, Briayan Rojas Guevara, Luis Cerdan Sanchez, Javier Moreno |
| author_role |
author |
| author2 |
Guevara, Luis Cerdan Sanchez, Javier Moreno |
| author2_role |
author author |
| dc.contributor.author.fl_str_mv |
Paredes, Briayan Rojas Guevara, Luis Cerdan Sanchez, Javier Moreno |
| dc.subject.es_PE.fl_str_mv |
moderately rigid soil |
| topic |
moderately rigid soil https://purl.org/pe-repo/ocde/ford#3.00.00 |
| dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#3.00.00 |
| description |
In most structural analyzes, Soil-Structure Interaction (SSI) is excluded, and it has been shown that SSI affects it depending on the type of structure and soil properties. Therefore, in this article, the structural response of an isolated system was analyzed, including the flexibility of the soil in moderately rigid soil, varying the number of levels of the building. To determine the dynamic coefficients of soil stiffness, NISTgcr 12-917-21 was used. Then, when determining the soil and isolator coefficients, two models are conducted for each structure: structure with isolator and structure with SSI + isolator. This study aimed to analyze the variations of the structural response of the 2 models, thus determining the feasibility of the SSI + LRB isolator in this type of soil. Likewise, it was determined to what extent the height of the building influences the period, the base displacements, the basal shear, and the maximum drift. Finally, it is concluded that for short-term regular buildings and on moderately rigid soil, the SSI does not affect or reduce the effectiveness of the LRB isolators. In addition, the isolated base structure experienced greater seismic effects compared to the isolated base + SSI structures. |
| publishDate |
2024 |
| dc.date.accessioned.none.fl_str_mv |
2024-09-15T15:13:24Z |
| dc.date.available.none.fl_str_mv |
2024-09-15T15:13:24Z |
| dc.date.issued.fl_str_mv |
2024-01-31 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.version.none.fl_str_mv |
http://purl.org/coar/version/c_970fb48d4fbd8a352 |
| format |
article |
| dc.identifier.issn.none.fl_str_mv |
0094243X |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.1063/5.0194856 |
| dc.identifier.uri.none.fl_str_mv |
http://hdl.handle.net/10757/675702 |
| dc.identifier.eissn.none.fl_str_mv |
15517616 |
| dc.identifier.journal.es_PE.fl_str_mv |
AIP Conference Proceedings |
| dc.identifier.eid.none.fl_str_mv |
2-s2.0-85184577383 |
| dc.identifier.scopusid.none.fl_str_mv |
SCOPUS_ID:85184577383 |
| identifier_str_mv |
0094243X 15517616 AIP Conference Proceedings 2-s2.0-85184577383 SCOPUS_ID:85184577383 |
| url |
https://doi.org/10.1063/5.0194856 http://hdl.handle.net/10757/675702 |
| dc.language.iso.es_PE.fl_str_mv |
eng |
| language |
eng |
| dc.rights.*.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.*.fl_str_mv |
http://creativecommons.org/licenses/by-nc-sa/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-sa/4.0/ |
| dc.format.es_PE.fl_str_mv |
application/html |
| dc.publisher.none.fl_str_mv |
American Institute of Physics Inc. |
| publisher.none.fl_str_mv |
American Institute of Physics Inc. |
| dc.source.none.fl_str_mv |
reponame:UPC-Institucional instname:Universidad Peruana de Ciencias Aplicadas instacron:UPC |
| instname_str |
Universidad Peruana de Ciencias Aplicadas |
| instacron_str |
UPC |
| institution |
UPC |
| reponame_str |
UPC-Institucional |
| collection |
UPC-Institucional |
| dc.source.journaltitle.none.fl_str_mv |
AIP Conference Proceedings |
| dc.source.volume.none.fl_str_mv |
3010 |
| dc.source.issue.none.fl_str_mv |
1 |
| bitstream.url.fl_str_mv |
https://repositorioacademico.upc.edu.pe/bitstream/10757/675702/2/license.txt https://repositorioacademico.upc.edu.pe/bitstream/10757/675702/1/license_rdf |
| bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 934f4ca17e109e0a05eaeaba504d7ce4 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Académico UPC |
| repository.mail.fl_str_mv |
upc@openrepository.com |
| _version_ |
1865095777267744768 |
| spelling |
cb35028491b995cc615b4475c45006a33006b9e98ba31eae64521bca03850b7722730077e537d690731b5b7e61116022ca323dParedes, Briayan RojasGuevara, Luis CerdanSanchez, Javier Moreno2024-09-15T15:13:24Z2024-09-15T15:13:24Z2024-01-310094243Xhttps://doi.org/10.1063/5.0194856http://hdl.handle.net/10757/67570215517616AIP Conference Proceedings2-s2.0-85184577383SCOPUS_ID:85184577383In most structural analyzes, Soil-Structure Interaction (SSI) is excluded, and it has been shown that SSI affects it depending on the type of structure and soil properties. Therefore, in this article, the structural response of an isolated system was analyzed, including the flexibility of the soil in moderately rigid soil, varying the number of levels of the building. To determine the dynamic coefficients of soil stiffness, NISTgcr 12-917-21 was used. Then, when determining the soil and isolator coefficients, two models are conducted for each structure: structure with isolator and structure with SSI + isolator. This study aimed to analyze the variations of the structural response of the 2 models, thus determining the feasibility of the SSI + LRB isolator in this type of soil. Likewise, it was determined to what extent the height of the building influences the period, the base displacements, the basal shear, and the maximum drift. Finally, it is concluded that for short-term regular buildings and on moderately rigid soil, the SSI does not affect or reduce the effectiveness of the LRB isolators. In addition, the isolated base structure experienced greater seismic effects compared to the isolated base + SSI structures.application/htmlengAmerican Institute of Physics Inc.info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-sa/4.0/moderately rigid soilhttps://purl.org/pe-repo/ocde/ford#3.00.00Soil structure interaction (SSI) influences the seismic response of a regular isolated building of 3, 6 and 10 stories in moderately rigid soilinfo:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a352AIP Conference Proceedings30101reponame:UPC-Institucionalinstname:Universidad Peruana de Ciencias Aplicadasinstacron:UPCLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorioacademico.upc.edu.pe/bitstream/10757/675702/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52falseCC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81031https://repositorioacademico.upc.edu.pe/bitstream/10757/675702/1/license_rdf934f4ca17e109e0a05eaeaba504d7ce4MD51false10757/675702oai:repositorioacademico.upc.edu.pe:10757/6757022026-02-17 17:40:06.79Repositorio Académico UPCupc@openrepository.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 |
| score |
13.468099 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).