This experimental work hopes to provide a potential solution by proposing techniques to improve the axial resistance capacity of reinforced concrete walls, using high-strength carbon filaments, and proposing a practical methodology for reinforcing existing reinforced concrete columns and walls. The...

Descripción completa

Detalles Bibliográficos
Autores: Bendezú R., Lenin, Cruz D., Luis Santa, Espinoza M., Elena
Formato: artículo
Fecha de Publicación:2024
Institución:Universidad Peruana de Ciencias Aplicadas
Repositorio:UPC-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorioacademico.upc.edu.pe:10757/676163
Enlace del recurso:http://hdl.handle.net/10757/676163
Nivel de acceso:acceso abierto
Materia:Carbon fibers polymers
increase -axial
resistance
Descripción
Sumario:This experimental work hopes to provide a potential solution by proposing techniques to improve the axial resistance capacity of reinforced concrete walls, using high-strength carbon filaments, and proposing a practical methodology for reinforcing existing reinforced concrete columns and walls. The methodology used to improve this work consists of the exploration and experimentation of two explicit parts, the first being a progression of material tests carried out in the laboratories of the Pontificia Universidad Católica del Perú, with the purpose of determining the direct mechanical properties. and not direct. The second part of the work included the analysis of the reinforced concrete walls through the non-linear concept modeled with the finite element method, verifying the non-linear attributes of the concrete by increasing the high-resistance carbon fiber. The results found have been obtained using the Cypecad software, and show that, in the case of carbon fiber reinforced specimens, a moment of 20.50 (tonf-m) is reached with respect to an axial load of 125.13 (tonf). On the other hand, the specimen without reinforcement reaches a moment of 18.20 (tonf-m) with respect to an axial load of 104.76 (tonf).
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).