Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger

Descripción del Articulo

Smart Battery Chargers (SBCs) implementing grid-forming (GFM) control strategies are a promising solution to provide voltage and frequency support, increasing the grid reliability. Typically, GFM studies consider inverters with high DC-link capacitance. Therefore, there is a research gap in two-stag...

Descripción completa

Detalles Bibliográficos
Autores: Sal y Rosas, Damián, Zarate, Alvaro
Formato: artículo
Fecha de Publicación:2023
Institución:Universidad Nacional de Ingeniería
Repositorio:UNI-Tesis
Lenguaje:inglés
OAI Identifier:oai:cybertesis.uni.edu.pe:20.500.14076/29145
Enlace del recurso:http://hdl.handle.net/20.500.14076/29145
https://doi.org/10.3390/en16020894
Nivel de acceso:acceso abierto
Materia:Grid-forming (GFM)
Active power decoupling (APD)
DC-link ripple
Electric vehicles (EV)
Smart Battery Charger (SBC)
Vehicle-to-grid (V2G)
vehicle-to-home (V2H)
https://purl.org/pe-repo/ocde/ford#2.02.00
id UUNI_b0cf72f4f03f2364b63f49b33f74419a
oai_identifier_str oai:cybertesis.uni.edu.pe:20.500.14076/29145
network_acronym_str UUNI
network_name_str UNI-Tesis
repository_id_str 1534
dc.title.en.fl_str_mv Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
title Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
spellingShingle Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
Sal y Rosas, Damián
Grid-forming (GFM)
Active power decoupling (APD)
DC-link ripple
Electric vehicles (EV)
Smart Battery Charger (SBC)
Vehicle-to-grid (V2G)
vehicle-to-home (V2H)
https://purl.org/pe-repo/ocde/ford#2.02.00
title_short Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
title_full Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
title_fullStr Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
title_full_unstemmed Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
title_sort Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Charger
dc.creator.none.fl_str_mv Zarate, Alvaro
Sal y Rosas, Damián
author Sal y Rosas, Damián
author_facet Sal y Rosas, Damián
Zarate, Alvaro
author_role author
author2 Zarate, Alvaro
author2_role author
dc.contributor.author.fl_str_mv Sal y Rosas, Damián
Zarate, Alvaro
dc.subject.en.fl_str_mv Grid-forming (GFM)
Active power decoupling (APD)
DC-link ripple
Electric vehicles (EV)
Smart Battery Charger (SBC)
Vehicle-to-grid (V2G)
vehicle-to-home (V2H)
topic Grid-forming (GFM)
Active power decoupling (APD)
DC-link ripple
Electric vehicles (EV)
Smart Battery Charger (SBC)
Vehicle-to-grid (V2G)
vehicle-to-home (V2H)
https://purl.org/pe-repo/ocde/ford#2.02.00
dc.subject.ocde.es.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.02.00
description Smart Battery Chargers (SBCs) implementing grid-forming (GFM) control strategies are a promising solution to provide voltage and frequency support, increasing the grid reliability. Typically, GFM studies consider inverters with high DC-link capacitance. Therefore, there is a research gap in two-stage DC-AC converters with small DC-link capacitance implementing GFM strategies. This article proposes a novel approach to implement a GFM control strategy along with active power decoupling (APD) in an isolated, single-phase, electrolytic-capacitor-free two-stage DC-AC structure. The structure is composed of a voltage source inverter (VSI), DC-linked by film capacitors, with a dual-active-bridge series-resonant (DABSR) DC-DC converter. High DC-link ripple is allowed and managed by the APD. Hence, electrolytic capacitors are avoided, increasing the converter lifetime. In the proposed approach, the VSI implements the GFM strategy, operating in the four quadrants of the active and reactive power plane. However, the DABSR allows galvanic isolation, average DC-link voltage control, and suppression of the low-frequency ripple on the battery current, minimizing the impact in the battery lifetime. Design criteria are given for the DC-link voltage controller, active-reactive power controllers, inner inverter controllers, and APD technique. The control strategy is validated for vehicle-to-grid and stand-alone vehicle-to-home applications, using hardware-in-the-loop for a 2kW test setup.
publishDate 2023
dc.date.accessioned.none.fl_str_mv 2026-04-06T20:14:48Z
dc.date.available.none.fl_str_mv 2026-04-06T20:14:48Z
dc.date.issued.fl_str_mv 2023-01
dc.type.es.fl_str_mv info:eu-repo/semantics/article
dc.type.version.es.fl_str_mv http://purl.org/coar/version/c_970fb48d4fbd8a85
format article
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/20.500.14076/29145
dc.identifier.doi.es.fl_str_mv https://doi.org/10.3390/en16020894
url http://hdl.handle.net/20.500.14076/29145
https://doi.org/10.3390/en16020894
dc.language.iso.en.fl_str_mv eng
language eng
dc.relation.ispartof.es.fl_str_mv Energies
dc.rights.es.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.format.es.fl_str_mv application/pdf
dc.publisher.es.fl_str_mv MDPI Open Access Journals
dc.source.es.fl_str_mv Universidad Nacional de Ingeniería
Repositorio Institucional - UNI
dc.source.none.fl_str_mv reponame:UNI-Tesis
instname:Universidad Nacional de Ingeniería
instacron:UNI
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
reponame_str UNI-Tesis
collection UNI-Tesis
bitstream.url.fl_str_mv http://cybertesis.uni.edu.pe/bitstream/20.500.14076/29145/3/salyrosas_d.pdf.txt
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/29145/2/license.txt
http://cybertesis.uni.edu.pe/bitstream/20.500.14076/29145/1/salyrosas_d.pdf
bitstream.checksum.fl_str_mv 1f3d36a4ba2cf0c626a2ffae00b465c0
8a4605be74aa9ea9d79846c1fba20a33
423f9de618fb53eea167923bd8c20b3d
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional Universidad Nacional de Ingeniería
repository.mail.fl_str_mv repositorio@uni.edu.pe
_version_ 1864818854812712960
spelling Sal y Rosas, DamiánZarate, AlvaroZarate, AlvaroSal y Rosas, Damián2026-04-06T20:14:48Z2026-04-06T20:14:48Z2023-01http://hdl.handle.net/20.500.14076/29145https://doi.org/10.3390/en16020894Smart Battery Chargers (SBCs) implementing grid-forming (GFM) control strategies are a promising solution to provide voltage and frequency support, increasing the grid reliability. Typically, GFM studies consider inverters with high DC-link capacitance. Therefore, there is a research gap in two-stage DC-AC converters with small DC-link capacitance implementing GFM strategies. This article proposes a novel approach to implement a GFM control strategy along with active power decoupling (APD) in an isolated, single-phase, electrolytic-capacitor-free two-stage DC-AC structure. The structure is composed of a voltage source inverter (VSI), DC-linked by film capacitors, with a dual-active-bridge series-resonant (DABSR) DC-DC converter. High DC-link ripple is allowed and managed by the APD. Hence, electrolytic capacitors are avoided, increasing the converter lifetime. In the proposed approach, the VSI implements the GFM strategy, operating in the four quadrants of the active and reactive power plane. However, the DABSR allows galvanic isolation, average DC-link voltage control, and suppression of the low-frequency ripple on the battery current, minimizing the impact in the battery lifetime. Design criteria are given for the DC-link voltage controller, active-reactive power controllers, inner inverter controllers, and APD technique. The control strategy is validated for vehicle-to-grid and stand-alone vehicle-to-home applications, using hardware-in-the-loop for a 2kW test setup.Submitted by Quispe Rabanal Flavio (flaviofime@hotmail.com) on 2026-04-06T20:14:48Z No. of bitstreams: 1 salyrosas_d.pdf: 9819430 bytes, checksum: 423f9de618fb53eea167923bd8c20b3d (MD5)Made available in DSpace on 2026-04-06T20:14:48Z (GMT). No. of bitstreams: 1 salyrosas_d.pdf: 9819430 bytes, checksum: 423f9de618fb53eea167923bd8c20b3d (MD5) Previous issue date: 2023-01Este trabajo fue financiado por el Programa Nacional de Investigación Científica y Estudios Avanzados (Prociencia - Perú) en el marco del "Manufactura Avanzada de Estaciones de recarga rápida de Vehículos Eléctricos basada en Sistemas Fotovoltaicos Inteligentes" [número de contrato 007-2021]application/pdfengMDPI Open Access JournalsEnergiesinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/4.0/Universidad Nacional de IngenieríaRepositorio Institucional - UNIreponame:UNI-Tesisinstname:Universidad Nacional de Ingenieríainstacron:UNIGrid-forming (GFM)Active power decoupling (APD)DC-link rippleElectric vehicles (EV)Smart Battery Charger (SBC)Vehicle-to-grid (V2G)vehicle-to-home (V2H)https://purl.org/pe-repo/ocde/ford#2.02.00Single-Phase Grid-Forming Strategy with Power Decoupling Implementation for Electrolytic-Capacitor-Free EV Smart Battery Chargerinfo:eu-repo/semantics/articlehttp://purl.org/coar/version/c_970fb48d4fbd8a85TEXTsalyrosas_d.pdf.txtsalyrosas_d.pdf.txtExtracted texttext/plain119351http://cybertesis.uni.edu.pe/bitstream/20.500.14076/29145/3/salyrosas_d.pdf.txt1f3d36a4ba2cf0c626a2ffae00b465c0MD53LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://cybertesis.uni.edu.pe/bitstream/20.500.14076/29145/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALsalyrosas_d.pdfsalyrosas_d.pdfapplication/pdf9819430http://cybertesis.uni.edu.pe/bitstream/20.500.14076/29145/1/salyrosas_d.pdf423f9de618fb53eea167923bd8c20b3dMD5120.500.14076/29145oai:cybertesis.uni.edu.pe:20.500.14076/291452026-04-07 02:44:00.96Repositorio Institucional Universidad Nacional de Ingenieríarepositorio@uni.edu.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
score 13.91977
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).