Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces
Descripción del Articulo
        High concentrations of CO2 levels are significantly present in closed environments that do not have proper ventilation. Such high concentrations generate negative health consequences such as dizziness, headaches and various respiratory problems. For this reason, the design and implementation of a lo...
              
            
    
                        | Autores: | , , | 
|---|---|
| Formato: | artículo | 
| Fecha de Publicación: | 2022 | 
| Institución: | Universidad Tecnológica del Perú | 
| Repositorio: | UTP-Institucional | 
| Lenguaje: | español | 
| OAI Identifier: | oai:repositorio.utp.edu.pe:20.500.12867/5803 | 
| Enlace del recurso: | https://hdl.handle.net/20.500.12867/5803 http://doi.org/10.14569/IJACSA.2022.0130363 | 
| Nivel de acceso: | acceso abierto | 
| Materia: | CO2 Monitoring Ventilation System Internet of things https://purl.org/pe-repo/ocde/ford#2.11.03 | 
| id | UTPD_39464da2d66b39a55f6cdcb65637acb8 | 
|---|---|
| oai_identifier_str | oai:repositorio.utp.edu.pe:20.500.12867/5803 | 
| network_acronym_str | UTPD | 
| network_name_str | UTP-Institucional | 
| repository_id_str | 4782 | 
| dc.title.es_PE.fl_str_mv | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces | 
| title | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces | 
| spellingShingle | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces Cavallini Rodriguez, Ramces Andrei CO2 Monitoring Ventilation System Internet of things https://purl.org/pe-repo/ocde/ford#2.11.03 | 
| title_short | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces | 
| title_full | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces | 
| title_fullStr | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces | 
| title_full_unstemmed | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces | 
| title_sort | Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spaces | 
| author | Cavallini Rodriguez, Ramces Andrei | 
| author_facet | Cavallini Rodriguez, Ramces Andrei Espinoza Valera, Jesus Alberto Francisco Sotomayor Beltran, Carlos Alberto | 
| author_role | author | 
| author2 | Espinoza Valera, Jesus Alberto Francisco Sotomayor Beltran, Carlos Alberto | 
| author2_role | author author | 
| dc.contributor.author.fl_str_mv | Cavallini Rodriguez, Ramces Andrei Espinoza Valera, Jesus Alberto Francisco Sotomayor Beltran, Carlos Alberto | 
| dc.subject.es_PE.fl_str_mv | CO2 Monitoring Ventilation System Internet of things | 
| topic | CO2 Monitoring Ventilation System Internet of things https://purl.org/pe-repo/ocde/ford#2.11.03 | 
| dc.subject.ocde.es_PE.fl_str_mv | https://purl.org/pe-repo/ocde/ford#2.11.03 | 
| description | High concentrations of CO2 levels are significantly present in closed environments that do not have proper ventilation. Such high concentrations generate negative health consequences such as dizziness, headaches and various respiratory problems. For this reason, the design and implementation of a low-cost CO2 monitoring and control prototype is proposed to optimize ventilation levels in closed spaces. The parameters that the proposed device measures are concentration of carbon dioxide, humidity and temperature. A digital PID controller was implemented, with the use of C++ programming language and an exhaust fan to stabilize carbon dioxide levels within a closed space. The aforementioned parameters can be viewed in two ways: The first way is locally through a LCD screen and LED indicators, and the second one, remotely using the free Arduino IoT Cloud platform. The closed environment was emulated using a cardboard box and in the tests it was obtained that the prototype manages to keep the CO2 concentration levels below the established limit. However, this can be further improved by using more precise sensors for more accurate results. It is expected that this model can be successfully scaled to closed spaces such as classrooms and offices. | 
| publishDate | 2022 | 
| dc.date.accessioned.none.fl_str_mv | 2022-07-27T16:00:27Z | 
| dc.date.available.none.fl_str_mv | 2022-07-27T16:00:27Z | 
| dc.date.issued.fl_str_mv | 2022 | 
| dc.type.es_PE.fl_str_mv | info:eu-repo/semantics/article | 
| dc.type.version.es_PE.fl_str_mv | info:eu-repo/semantics/publishedVersion | 
| format | article | 
| status_str | publishedVersion | 
| dc.identifier.issn.none.fl_str_mv | 2156-5570 | 
| dc.identifier.uri.none.fl_str_mv | https://hdl.handle.net/20.500.12867/5803 | 
| dc.identifier.journal.es_PE.fl_str_mv | International Journal of Advanced Computer Science and Applications | 
| dc.identifier.doi.none.fl_str_mv | http://doi.org/10.14569/IJACSA.2022.0130363 | 
| identifier_str_mv | 2156-5570 International Journal of Advanced Computer Science and Applications | 
| url | https://hdl.handle.net/20.500.12867/5803 http://doi.org/10.14569/IJACSA.2022.0130363 | 
| dc.language.iso.es_PE.fl_str_mv | spa | 
| language | spa | 
| dc.relation.ispartofseries.none.fl_str_mv | International Journal of Advanced Computer Science and Applications;vol. 13, n° 3, pp. 529 - 537 | 
| dc.rights.es_PE.fl_str_mv | info:eu-repo/semantics/openAccess | 
| dc.rights.uri.es_PE.fl_str_mv | http://creativecommons.org/licenses/by/4.0/ | 
| eu_rights_str_mv | openAccess | 
| rights_invalid_str_mv | http://creativecommons.org/licenses/by/4.0/ | 
| dc.format.es_PE.fl_str_mv | application/pdf | 
| dc.publisher.es_PE.fl_str_mv | Science and Information Organization | 
| dc.publisher.country.es_PE.fl_str_mv | GB | 
| dc.source.es_PE.fl_str_mv | Repositorio Institucional - UTP Universidad Tecnológica del Perú | 
| dc.source.none.fl_str_mv | reponame:UTP-Institucional instname:Universidad Tecnológica del Perú instacron:UTP | 
| instname_str | Universidad Tecnológica del Perú | 
| instacron_str | UTP | 
| institution | UTP | 
| reponame_str | UTP-Institucional | 
| collection | UTP-Institucional | 
| bitstream.url.fl_str_mv | http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/1/R.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/2/license.txt http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/3/R.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.txt http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/4/R.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.jpg | 
| bitstream.checksum.fl_str_mv | d517d7e84efd967fc37b7481cfbe15c0 8a4605be74aa9ea9d79846c1fba20a33 37ecf9f963833bb25b6ef5a94a9fa958 87c692a4eac795d158069a78bf8816b6 | 
| bitstream.checksumAlgorithm.fl_str_mv | MD5 MD5 MD5 MD5 | 
| repository.name.fl_str_mv | Repositorio Institucional de la Universidad Tecnológica del Perú | 
| repository.mail.fl_str_mv | repositorio@utp.edu.pe | 
| _version_ | 1817984829925359616 | 
| spelling | Cavallini Rodriguez, Ramces AndreiEspinoza Valera, Jesus Alberto FranciscoSotomayor Beltran, Carlos Alberto2022-07-27T16:00:27Z2022-07-27T16:00:27Z20222156-5570https://hdl.handle.net/20.500.12867/5803International Journal of Advanced Computer Science and Applicationshttp://doi.org/10.14569/IJACSA.2022.0130363High concentrations of CO2 levels are significantly present in closed environments that do not have proper ventilation. Such high concentrations generate negative health consequences such as dizziness, headaches and various respiratory problems. For this reason, the design and implementation of a low-cost CO2 monitoring and control prototype is proposed to optimize ventilation levels in closed spaces. The parameters that the proposed device measures are concentration of carbon dioxide, humidity and temperature. A digital PID controller was implemented, with the use of C++ programming language and an exhaust fan to stabilize carbon dioxide levels within a closed space. The aforementioned parameters can be viewed in two ways: The first way is locally through a LCD screen and LED indicators, and the second one, remotely using the free Arduino IoT Cloud platform. The closed environment was emulated using a cardboard box and in the tests it was obtained that the prototype manages to keep the CO2 concentration levels below the established limit. However, this can be further improved by using more precise sensors for more accurate results. It is expected that this model can be successfully scaled to closed spaces such as classrooms and offices.Campus Lima Centroapplication/pdfspaScience and Information OrganizationGBInternational Journal of Advanced Computer Science and Applications;vol. 13, n° 3, pp. 529 - 537info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by/4.0/Repositorio Institucional - UTPUniversidad Tecnológica del Perúreponame:UTP-Institucionalinstname:Universidad Tecnológica del Perúinstacron:UTPCO2 MonitoringVentilation SystemInternet of thingshttps://purl.org/pe-repo/ocde/ford#2.11.03Design and implementation of a low-cost CO2 monitoring and control system prototype to optimize ventilation levels in closed spacesinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionORIGINALR.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdfR.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdfapplication/pdf1040928http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/1/R.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdfd517d7e84efd967fc37b7481cfbe15c0MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52TEXTR.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.txtR.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.txtExtracted texttext/plain30828http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/3/R.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.txt37ecf9f963833bb25b6ef5a94a9fa958MD53THUMBNAILR.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.jpgR.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.jpgGenerated Thumbnailimage/jpeg25513http://repositorio.utp.edu.pe/bitstream/20.500.12867/5803/4/R.Cavallini_J.Espinoza_C.Sotomayor_IJACSA_Articulo_spa_2022.pdf.jpg87c692a4eac795d158069a78bf8816b6MD5420.500.12867/5803oai:repositorio.utp.edu.pe:20.500.12867/58032022-08-06 17:04:05.64Repositorio Institucional de la Universidad Tecnológica del Perúrepositorio@utp.edu.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 | 
| score | 13.917302 | 
 Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
    La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
 
   
   
             
            