Wastewater treatment of a municipal slaughterhouse in the city of Tacna-Peru using an upflow anaerobic sludge blanket reactor

Descripción del Articulo

The present research study was carried out at the Mario Eyzaguirre municipal slaughterhouse in the city of Tacna, Peru where the design, construction, and evaluation of a water treatment system comprising catchment units, a desander, a settling tank, a grease trap, and an Upflow Anaerobic Sludge Bla...

Descripción completa

Detalles Bibliográficos
Autores: Gonzales-Condori, Elvis Gilmar, Mendoza-Aquino, Marisol, Vargas-Flores, Cristian Reynaro, Jiménez-Muñiz, Yael Osmar, Huarachi-Nuñe, Yannela Dayanna, Herrera-Villanueva, Alvaro Nilton
Formato: objeto de conferencia
Fecha de Publicación:2024
Institución:Universidad Tecnológica del Perú
Repositorio:UTP-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.utp.edu.pe:20.500.12867/14451
Enlace del recurso:https://hdl.handle.net/20.500.12867/14451
https://doi.org/10.18687/LACCEI2024.1.1.140
Nivel de acceso:acceso abierto
Materia:Slaughterhouse
Wastewater
Sludge Blanket
https://purl.org/pe-repo/ocde/ford#2.11.04
Descripción
Sumario:The present research study was carried out at the Mario Eyzaguirre municipal slaughterhouse in the city of Tacna, Peru where the design, construction, and evaluation of a water treatment system comprising catchment units, a desander, a settling tank, a grease trap, and an Upflow Anaerobic Sludge Blanket (UASB) was proposed. The initial and final values of BOD5, COD, ammoniacal nitrogen, oils and fats, pH, total dissolved solids, and total dissolved solids were used as indicators of treatment efficiency. The results show a percentage of removal at a temperature of 20°C of 36 % of COD and 35 % of BOD, and the results for temperature values at 35°C showed improvements in the removal of organic pollutants with an average value of 54 % for BOD5 and 45 % for COD. To improve the study proposal, units such as coagulation, flocculation, filtration, and disinfection were complemented and installed after the UASB, where the results indicate improvements in water quality up to 70.84 % for BOD5 and 70.69 % for COD. The present study demonstrates that applying a UASB in a municipal animal feedlot can considerably reduce the pollution of its effluents.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).