Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A

Descripción del Articulo

The present study aims to assess the gases emitted by burning rice husk in the drying process in the factory of Cementos Selva SA, during the months of December 2009, January, February and March 2010, taking into account the importance of involving the use of this by-product that eliminates toda y t...

Descripción completa

Detalles Bibliográficos
Autor: Chávez Cabrera, Alcidia
Formato: tesis de grado
Fecha de Publicación:2010
Institución:Universidad Nacional de San Martin - Tarapoto
Repositorio:UNSM-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unsm.edu.pe:11458/166
Enlace del recurso:http://hdl.handle.net/11458/166
Nivel de acceso:acceso abierto
Materia:Evaluación
gases
combustión
proceso
secado
utilizando
cascarilla
arroz
lignito
planta
cementos
Selva
SA
id UNSM_daacfb76b45a9f0f08912ffb98ba7368
oai_identifier_str oai:repositorio.unsm.edu.pe:11458/166
network_acronym_str UNSM
network_name_str UNSM-Institucional
repository_id_str
dc.title.es_PE.fl_str_mv Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
title Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
spellingShingle Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
Chávez Cabrera, Alcidia
Evaluación
gases
combustión
proceso
secado
utilizando
cascarilla
arroz
lignito
planta
cementos
Selva
SA
title_short Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
title_full Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
title_fullStr Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
title_full_unstemmed Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
title_sort Evaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.A
author Chávez Cabrera, Alcidia
author_facet Chávez Cabrera, Alcidia
author_role author
dc.contributor.advisor.fl_str_mv Torres Delgado, Jorge
dc.contributor.author.fl_str_mv Chávez Cabrera, Alcidia
dc.subject.es_PE.fl_str_mv Evaluación
gases
combustión
proceso
secado
utilizando
cascarilla
arroz
lignito
planta
cementos
Selva
SA
topic Evaluación
gases
combustión
proceso
secado
utilizando
cascarilla
arroz
lignito
planta
cementos
Selva
SA
description The present study aims to assess the gases emitted by burning rice husk in the drying process in the factory of Cementos Selva SA, during the months of December 2009, January, February and March 2010, taking into account the importance of involving the use of this by-product that eliminates toda y through open burning, which results in energy losses, as well as the emission of several pollutants. As for the measurements of concentrations of combustion gases, these were made with a frequency of once a week, at random, where the Continuous Emissions Monitoring (CEM), was conducted over a total period of 60 minutes, time intervals of 15 minutes, obtaining concentrations of the gases carbon monoxide (CO), nitrogen oxides (NOx) and sulfur dioxide (S02), which when contrasted with the permissible limits (MPL) of legislation environmental legislation, and through the use of a statistical test, it was determined that fall below the LMP. During the stage of field study was conducted activities such as measuring the moisture content of rice husks, before entering the combustion chamber, giving mínimum and maximum values ranging between 9.48% and 20.94% respectively, were likewise measurements of the calorific value of husk which resulted in values between 293 7 kcal 1 kg and 3328 Kcal 1 kg and for the implementation of these activities were used environments and procedures, the quality controllaboratory, located within the premises of plant of Cementos Selva SA The temperature of the combustion chamber was recorded on the control panel of the dryer area, ranging from 176 o C and 679 o C, these temperatures affect the concentrations of combustion gases emitted into the environment. In addition to the stage of cabinet was used meteorological data such as temperature and relative humidity recorded by the Vantage Pro 2 and provided by the company, data that were used for sorne comparisons.
publishDate 2010
dc.date.accessioned.none.fl_str_mv 2016-11-02T19:04:06Z
dc.date.available.none.fl_str_mv 2016-11-02T19:04:06Z
dc.date.issued.fl_str_mv 2010
dc.type.en_US.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.citation.es_PE.fl_str_mv Apa
dc.identifier.other.none.fl_str_mv 6051209
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/11458/166
identifier_str_mv Apa
6051209
url http://hdl.handle.net/11458/166
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.en_US.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Universidad Nacional de San Martín
dc.source.es_PE.fl_str_mv Universidad Nacional de San Martín
Repositorio de Tesis – UNSM
dc.source.none.fl_str_mv reponame:UNSM-Institucional
instname:Universidad Nacional de San Martin - Tarapoto
instacron:UNSM
instname_str Universidad Nacional de San Martin - Tarapoto
instacron_str UNSM
institution UNSM
reponame_str UNSM-Institucional
collection UNSM-Institucional
bitstream.url.fl_str_mv http://repositorio.unsm.edu.pe/bitstream/11458/166/3/6051209.pdf.jpg
http://repositorio.unsm.edu.pe/bitstream/11458/166/1/6051209.pdf
http://repositorio.unsm.edu.pe/bitstream/11458/166/2/6051209.pdf.txt
bitstream.checksum.fl_str_mv ac04442cca4ef3eae865f0dff28f0bfd
ecab246554f7342690d07015138c9388
d7955857e9ba18dc7efb41a3b0b36f76
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Institucional de la Universidad
repository.mail.fl_str_mv repositorio@unsm.edu.pe
_version_ 1741962204260859904
spelling Torres Delgado, Jorge29a0469f-10dd-4020-bfa4-ad8d3785e15aChávez Cabrera, Alcidia2016-11-02T19:04:06Z2016-11-02T19:04:06Z2010Apa6051209http://hdl.handle.net/11458/166The present study aims to assess the gases emitted by burning rice husk in the drying process in the factory of Cementos Selva SA, during the months of December 2009, January, February and March 2010, taking into account the importance of involving the use of this by-product that eliminates toda y through open burning, which results in energy losses, as well as the emission of several pollutants. As for the measurements of concentrations of combustion gases, these were made with a frequency of once a week, at random, where the Continuous Emissions Monitoring (CEM), was conducted over a total period of 60 minutes, time intervals of 15 minutes, obtaining concentrations of the gases carbon monoxide (CO), nitrogen oxides (NOx) and sulfur dioxide (S02), which when contrasted with the permissible limits (MPL) of legislation environmental legislation, and through the use of a statistical test, it was determined that fall below the LMP. During the stage of field study was conducted activities such as measuring the moisture content of rice husks, before entering the combustion chamber, giving mínimum and maximum values ranging between 9.48% and 20.94% respectively, were likewise measurements of the calorific value of husk which resulted in values between 293 7 kcal 1 kg and 3328 Kcal 1 kg and for the implementation of these activities were used environments and procedures, the quality controllaboratory, located within the premises of plant of Cementos Selva SA The temperature of the combustion chamber was recorded on the control panel of the dryer area, ranging from 176 o C and 679 o C, these temperatures affect the concentrations of combustion gases emitted into the environment. In addition to the stage of cabinet was used meteorological data such as temperature and relative humidity recorded by the Vantage Pro 2 and provided by the company, data that were used for sorne comparisons.El presente trabajo, tiene como objetivo, evaluar los gases emitidos por la combustión de la cascarilla de arroz en el proceso de secado en la fábrica de Cementos Selva S.A., durante los meses de diciembre del 2009, enero, febrero y marzo del 2010, teniendo en consideración la importancia que implica la utilización de este sub producto que hoy en día se elimina por medio de la combustión a cielo abierto, el cual resulta en pérdidas de energía, así como también en la emisión de varios contaminantes. En cuanto a las mediciones de las concentraciones de los gases de combustión, estas se efectuaron con una frecuencia de una vez por semana, al azar, donde el Monitoreo Continuo de Emisiones (MCE), se realizó durante un periodo total de 60 minutos, con intervalos de tiempo de 15 minutos, obteniendo concentraciones para los gases de monóxido de carbono (CO), óxidos de nitrógeno (NOx) y dióxido de azufre (S02), los que al ser contrastados con los Límites Máximos Permisibles (LMP) de la legislación ambiental vigente, y mediante la utilización de una prueba estadística, se determinó que encuentran por debajo de los LMP. Durante la etapa de campo se realizaron actividades tales como las mediciones del porcentaje de humedad de la cascarilla de arroz, antes del ingreso a la cámara de combustión, obteniendo valores mínimos y máximos que fluctuaron entre 9.48% y 20.94% respectivamente,así mismo se realizaron mediciones del poder calorífico de la cascarilla obteniendo como resultado valores entre 2937 Kcal/Kg y 3328 Kcal/Kg; para la ejecución de estas actividades se utilizaron los ambientes y procedimientos establecidos, en el laboratorio de control de calidad, ubicada dentro de las instalaciones de la planta de Cementos Selva S.A. La temperatura de la cámara de combustión fue registrada del tablero de control del área del secador, variando entre 176°C y 679 °C, dichas temperaturas influyen en las concentraciones de los gases de combustión emitidos al ambiente. Además para la etapa de gabinete se utilizó datos meteorológicos tales como la temperatura ambiental y la humedad relativa, registrada por la estación V ANT AGE PRO 2 y proporcionada por la empresa, datos que fueron utilizados para algunas comparaciones.Tesisapplication/pdfspaUniversidad Nacional de San Martíninfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de San MartínRepositorio de Tesis – UNSMreponame:UNSM-Institucionalinstname:Universidad Nacional de San Martin - Tarapotoinstacron:UNSMEvaluacióngasescombustiónprocesosecadoutilizandocascarillaarrozlignitoplantacementosSelvaSAEvaluación de los gases de combustión del proceso de secado, utilizando cascarilla de arroz y lignito en la planta de cementos Selva S.Ainfo:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalIngenieria AmbientalUniversidad Nacional de San Martín.Facultad de EcologíaIngeniero AmbientalTHUMBNAIL6051209.pdf.jpg6051209.pdf.jpgGenerated Thumbnailimage/jpeg975http://repositorio.unsm.edu.pe/bitstream/11458/166/3/6051209.pdf.jpgac04442cca4ef3eae865f0dff28f0bfdMD53ORIGINAL6051209.pdfapplication/pdf3171330http://repositorio.unsm.edu.pe/bitstream/11458/166/1/6051209.pdfecab246554f7342690d07015138c9388MD51TEXT6051209.pdf.txt6051209.pdf.txtExtracted texttext/plain180430http://repositorio.unsm.edu.pe/bitstream/11458/166/2/6051209.pdf.txtd7955857e9ba18dc7efb41a3b0b36f76MD5211458/166oai:repositorio.unsm.edu.pe:11458/1662021-12-15 03:24:33.666Repositorio Institucional de la Universidadrepositorio@unsm.edu.pe
score 13.958014
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).