Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura
Descripción del Articulo
        The investigation has been developed based on the treatment of Acid Mine Drainage (AMD) naturally emitted within the operations of the La Zanja mining unit, said Acid Drainage is the result of the oxidation of metal sulfides, in the presence of atmospheric oxygen. and water being one of the main sou...
              
            
    
                        | Autor: | |
|---|---|
| Formato: | tesis de grado | 
| Fecha de Publicación: | 2023 | 
| Institución: | Universidad Nacional de Trujillo | 
| Repositorio: | UNITRU-Tesis | 
| Lenguaje: | español | 
| OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/16621 | 
| Enlace del recurso: | https://hdl.handle.net/20.500.14414/16621 | 
| Nivel de acceso: | acceso abierto | 
| Materia: | Tratamiento del Drenaje Acido de Minas | 
| id | UNIT_fd44d8accbe0c2a10befac947a3949c2 | 
|---|---|
| oai_identifier_str | oai:dspace.unitru.edu.pe:20.500.14414/16621 | 
| network_acronym_str | UNIT | 
| network_name_str | UNITRU-Tesis | 
| repository_id_str | 4801 | 
| dc.title.es_PE.fl_str_mv | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura | 
| title | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura | 
| spellingShingle | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura Custodio Sánchez, Alexis Rafael Tratamiento del Drenaje Acido de Minas | 
| title_short | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura | 
| title_full | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura | 
| title_fullStr | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura | 
| title_full_unstemmed | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura | 
| title_sort | Colección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventura | 
| author | Custodio Sánchez, Alexis Rafael | 
| author_facet | Custodio Sánchez, Alexis Rafael | 
| author_role | author | 
| dc.contributor.advisor.fl_str_mv | Castillo Chung, Aldo Roger | 
| dc.contributor.author.fl_str_mv | Custodio Sánchez, Alexis Rafael | 
| dc.subject.es_PE.fl_str_mv | Tratamiento del Drenaje Acido de Minas | 
| topic | Tratamiento del Drenaje Acido de Minas | 
| description | The investigation has been developed based on the treatment of Acid Mine Drainage (AMD) naturally emitted within the operations of the La Zanja mining unit, said Acid Drainage is the result of the oxidation of metal sulfides, in the presence of atmospheric oxygen. and water being one of the main sources of contamination of surface and groundwater, these drainages are toxic to varying degrees for man, fauna and vegetation because, having a low pH, they contain a large amount of solids in suspension with a high content of sulfate and metals (Fe, Al, Mn, Zn, Cu, Pb, Hg, Cd, Ni), of the order of several hundred milligrams per liter. For the treatment of DAM, active treatment methods are used that consist of treating with alkaline chemical reagents to raise the pH, neutralize the acidity and precipitate the metals, being the HDS process (high density sludge) used in the San Pedro Sur plant and It is characterized by the use of calcium oxide to prepare the milk of lime and precipitate metals as insoluble hydroxides in a pH range that is usually between 6.5 and 9.5. Ferrous iron becomes ferrous hydroxide at a pH greater than 7.5, manganese becomes insoluble when pH is above 9 and aluminum precipitates as hydroxide at pH above 7. Sampling before and after treatment for the measurement of physical-chemical parameters as well as the analysis of total and dissolved metals must be carried out in accordance with the Water and Effluent Monitoring Protocol published by MINEM, although the values of pH were low and the heavy metal contents were high, it was achieved that the effluent values obtained after the treatment are in accordance with the standards established for its discharge or reuse and must be compared according to the Maximum Permissible Limits for the discharge of liquid effluents from Mining – Metallurgical Activities approved under D.S. No. 010-2010-MINAM | 
| publishDate | 2023 | 
| dc.date.accessioned.none.fl_str_mv | 2023-04-11T19:34:56Z | 
| dc.date.available.none.fl_str_mv | 2023-04-11T19:34:56Z | 
| dc.date.issued.fl_str_mv | 2023-04 | 
| dc.type.es_PE.fl_str_mv | info:eu-repo/semantics/bachelorThesis | 
| format | bachelorThesis | 
| dc.identifier.uri.none.fl_str_mv | https://hdl.handle.net/20.500.14414/16621 | 
| url | https://hdl.handle.net/20.500.14414/16621 | 
| dc.language.iso.es_PE.fl_str_mv | spa | 
| language | spa | 
| dc.relation.ispartof.fl_str_mv | SUNEDU | 
| dc.relation.ispartofseries.none.fl_str_mv | Tmet; | 
| dc.rights.es_PE.fl_str_mv | info:eu-repo/semantics/openAccess | 
| dc.rights.uri.es_PE.fl_str_mv | https://creativecommons.org/licenses/by/2.5/pe/ | 
| eu_rights_str_mv | openAccess | 
| rights_invalid_str_mv | https://creativecommons.org/licenses/by/2.5/pe/ | 
| dc.publisher.es_PE.fl_str_mv | Universidad Nacional de Trujillo | 
| dc.source.es_PE.fl_str_mv | Universidad Nacional de Trujillo Repositorio institucional - UNITRU | 
| dc.source.none.fl_str_mv | reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU | 
| instname_str | Universidad Nacional de Trujillo | 
| instacron_str | UNITRU | 
| institution | UNITRU | 
| reponame_str | UNITRU-Tesis | 
| collection | UNITRU-Tesis | 
| bitstream.url.fl_str_mv | https://dspace.unitru.edu.pe/bitstreams/8f853d93-2506-413a-9975-156d37b0ad1b/download https://dspace.unitru.edu.pe/bitstreams/95cbe821-f635-4b3f-b430-7ee2dd27975a/download | 
| bitstream.checksum.fl_str_mv | 8318e4ddfe1cd763d78f7784237d7863 8a4605be74aa9ea9d79846c1fba20a33 | 
| bitstream.checksumAlgorithm.fl_str_mv | MD5 MD5 | 
| repository.name.fl_str_mv | Repositorio Institucional - UNITRU | 
| repository.mail.fl_str_mv | repositorios@unitru.edu.pe | 
| _version_ | 1807290502221922304 | 
| spelling | Castillo Chung, Aldo RogerCustodio Sánchez, Alexis Rafael2023-04-11T19:34:56Z2023-04-11T19:34:56Z2023-04https://hdl.handle.net/20.500.14414/16621The investigation has been developed based on the treatment of Acid Mine Drainage (AMD) naturally emitted within the operations of the La Zanja mining unit, said Acid Drainage is the result of the oxidation of metal sulfides, in the presence of atmospheric oxygen. and water being one of the main sources of contamination of surface and groundwater, these drainages are toxic to varying degrees for man, fauna and vegetation because, having a low pH, they contain a large amount of solids in suspension with a high content of sulfate and metals (Fe, Al, Mn, Zn, Cu, Pb, Hg, Cd, Ni), of the order of several hundred milligrams per liter. For the treatment of DAM, active treatment methods are used that consist of treating with alkaline chemical reagents to raise the pH, neutralize the acidity and precipitate the metals, being the HDS process (high density sludge) used in the San Pedro Sur plant and It is characterized by the use of calcium oxide to prepare the milk of lime and precipitate metals as insoluble hydroxides in a pH range that is usually between 6.5 and 9.5. Ferrous iron becomes ferrous hydroxide at a pH greater than 7.5, manganese becomes insoluble when pH is above 9 and aluminum precipitates as hydroxide at pH above 7. Sampling before and after treatment for the measurement of physical-chemical parameters as well as the analysis of total and dissolved metals must be carried out in accordance with the Water and Effluent Monitoring Protocol published by MINEM, although the values of pH were low and the heavy metal contents were high, it was achieved that the effluent values obtained after the treatment are in accordance with the standards established for its discharge or reuse and must be compared according to the Maximum Permissible Limits for the discharge of liquid effluents from Mining – Metallurgical Activities approved under D.S. No. 010-2010-MINAMLa investigación se ha desarrollado en base al tratamiento del Drenaje Ácido de mina (DAM) emitida en forma natural dentro de las operaciones de la unidad minera la zanja, dicho Drenaje Ácido es el resultado de la oxidación de sulfuros metálicos, en presencia de oxígeno atmosférico y agua siendo una de las principales fuentes de contaminación de las aguas superficiales y subterráneas, estos drenajes son tóxicos en diverso grado para el hombre, la fauna y la vegetación porque al tener un pH bajo, estas contienen una gran cantidad de sólidos en suspensión con un alto contenido en sulfato y metales (Fe, Al, Mn, Zn, Cu, Pb, Hg, Cd, Ni), del orden de varios cientos de miligramos por litro. Para el tratamiento del DAM se usa métodos de tratamientos activos que consiste en tratar con reactivos químicos alcalinos para elevar el pH, neutralizar la acidez y precipitar los metales, siendo el proceso HDS (lodos de alta densidad) utilizado en la planta San Pedro Sur y se caracteriza por el uso del óxido de calcio para preparar la lechada de cal y precipitar los metales como hidróxidos insolubles en un intervalo de pH que suele estar comprendido entre 6.5 a 9.5, El hierro se convierte en hidróxido ferroso a pH superior a 7.5 , el manganeso se transforma en insoluble cuando el pH es superior a 9 y el aluminio precipita en forma de hidróxido a pH superiores a 7. Las tomas de muestras antes y después del tratamiento para la medición de los parámetros físico-químicos así como el análisis de metales totales y disueltos, se deben realizar de acuerdo al Protocolo de Monitoreo de Aguas y Efluentes publicado por el MINEM, aunque los valores de pH fueron bajos y los contenidos de metales pesados fueron altos se logró que los valores del efluente obtenidos después del tratamiento estén de acuerdo con los estándares establecidos para su vertimiento o reutilización y deberán de ser comparados de acuerdo a los Límites Máximos Permisibles para la descarga de efluentes líquidos de Actividades Minero – Metalúrgicas aprobados bajo D.S. N°010-2010-MINAM.TesisspaUniversidad Nacional de TrujilloTmet;SUNEDUinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUTratamiento del Drenaje Acido de MinasColección y tratamiento del Drenaje Acido de Minas de la Unidad Minera La Zanja del Grupo Buenaventurainfo:eu-repo/semantics/bachelorThesisTítulo ProfesionalIngeniero MetalurgistaIngeniería MecanicaUniversidad Nacional de Trujillo.Facultad de IngenieríaORIGINALCustodio Sánchez.pdfCustodio Sánchez.pdfTratamiento del Drenaje Acido de Minasapplication/pdf9065410https://dspace.unitru.edu.pe/bitstreams/8f853d93-2506-413a-9975-156d37b0ad1b/download8318e4ddfe1cd763d78f7784237d7863MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/95cbe821-f635-4b3f-b430-7ee2dd27975a/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/16621oai:dspace.unitru.edu.pe:20.500.14414/166212023-04-11 14:34:56.624https://creativecommons.org/licenses/by/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 | 
| score | 13.913218 | 
 Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
    La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
 
   
   
             
            