Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018
Descripción del Articulo
In this report, the quality of the packaging materials used for conditioning Meropenem 500mg powder for injectable suspension (PPS) in a Pharmaceutical Industry was determined during the year 2018. A batch of packaging and packaging materials was evaluated as vials, plugs, seals, boxes and inserts,...
Autor: | |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2019 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/14177 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/14177 |
Nivel de acceso: | acceso abierto |
Materia: | Material de envase y empaque acondicionamiento control de calidad |
id |
UNIT_c9f9f6971c343f8f6c3a16a069add92b |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/14177 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_PE.fl_str_mv |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 |
title |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 |
spellingShingle |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 Calderón Piminchumo, Dennis Alberto Material de envase y empaque acondicionamiento control de calidad |
title_short |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 |
title_full |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 |
title_fullStr |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 |
title_full_unstemmed |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 |
title_sort |
Calidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018 |
author |
Calderón Piminchumo, Dennis Alberto |
author_facet |
Calderón Piminchumo, Dennis Alberto |
author_role |
author |
dc.contributor.advisor.fl_str_mv |
Aro Díaz, Rubén Jesús |
dc.contributor.author.fl_str_mv |
Calderón Piminchumo, Dennis Alberto |
dc.subject.es_PE.fl_str_mv |
Material de envase y empaque acondicionamiento control de calidad |
topic |
Material de envase y empaque acondicionamiento control de calidad |
description |
In this report, the quality of the packaging materials used for conditioning Meropenem 500mg powder for injectable suspension (PPS) in a Pharmaceutical Industry was determined during the year 2018. A batch of packaging and packaging materials was evaluated as vials, plugs, seals, boxes and inserts, for this the tables of Simple Sampling Plans for Normal Inspection and acceptable quality levels (AQL) were used. The search for possible defects was carried out throughout the inspection process, sampling, and analysis of such materials; this was determined by the classification of standardized defects in the industry (critical defect, major or minor). The methodology was based on the realization of physicochemical tests for corks, vials according to American Pharmacopoeia USP41-NF36 and also evaluated by tests by attributes the quality of the mediate container (box), seals and inserts, according to the laboratory's own technique. In conclusion, the quality of the packaging materials meet all the technical specifications for conditioning Meropenem 500mg P.P.S. ; The quality of the immediate glass container (vial) and caps were according to American Pharmacopoeia USP41-NF36 and the quality of the mediated container (box), seals and inserts were according to the laboratory's own technique |
publishDate |
2019 |
dc.date.accessioned.none.fl_str_mv |
2019-10-02T18:44:27Z |
dc.date.available.none.fl_str_mv |
2019-10-02T18:44:27Z |
dc.date.issued.fl_str_mv |
2019 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/14177 |
url |
https://hdl.handle.net/20.500.14414/14177 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/80227f48-3391-441c-8495-c556392ffbc8/download https://dspace.unitru.edu.pe/bitstreams/84ae8432-05b8-40ae-9ab6-321d8fb8a381/download |
bitstream.checksum.fl_str_mv |
e164cc5ef3f0407ac702b6710299318f 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807289888418037760 |
spelling |
Aro Díaz, Rubén JesúsCalderón Piminchumo, Dennis Alberto2019-10-02T18:44:27Z2019-10-02T18:44:27Z2019https://hdl.handle.net/20.500.14414/14177In this report, the quality of the packaging materials used for conditioning Meropenem 500mg powder for injectable suspension (PPS) in a Pharmaceutical Industry was determined during the year 2018. A batch of packaging and packaging materials was evaluated as vials, plugs, seals, boxes and inserts, for this the tables of Simple Sampling Plans for Normal Inspection and acceptable quality levels (AQL) were used. The search for possible defects was carried out throughout the inspection process, sampling, and analysis of such materials; this was determined by the classification of standardized defects in the industry (critical defect, major or minor). The methodology was based on the realization of physicochemical tests for corks, vials according to American Pharmacopoeia USP41-NF36 and also evaluated by tests by attributes the quality of the mediate container (box), seals and inserts, according to the laboratory's own technique. In conclusion, the quality of the packaging materials meet all the technical specifications for conditioning Meropenem 500mg P.P.S. ; The quality of the immediate glass container (vial) and caps were according to American Pharmacopoeia USP41-NF36 and the quality of the mediated container (box), seals and inserts were according to the laboratory's own techniqueEn el presente informe se determinó la calidad de los materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg polvo para suspensión inyectable (P.P.S.) en una Industria Farmacéutica, durante el año 2018. Se evaluó un lote de materiales de envase y empaque como viales, tapones, precintos, cajas e insertos, para ello se empleó las tablas de Planes de Muestreo Simple para Inspección Normal y los niveles de calidad aceptable (AQL).La búsqueda de los posibles defectos se llevó a cabo durante todo el proceso de inspección, muestreo, y análisis de dichos materiales; esto se determinó mediante la clasificación de defectos estandarizados en la industria (defecto crítico, mayor o menor).La metodología se basó en la realización de pruebas fisicoquímicas para tapones ,viales según Farmacopea Americana USP41-NF36 y también se evaluó mediante pruebas por atributos la calidad del envase mediato (caja) , precintos e insertos, según técnica propia del laboratorio. En conclusión, la calidad de los materiales de envase y empaque cumplen con todos las especificaciones técnicas para el acondicionamiento de Meropenem 500mg P.P.S. ; la calidad del envase inmediato de vidrio (vial) y tapones fueron conforme según Farmacopea Americana USP41-NF36 y la calidad del envase mediato (caja) , precintos e insertos fueron conforme según técnica propia del laboratorioTesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUMaterial de envase y empaqueacondicionamientocontrol de calidadCalidad de materiales de envase y empaque utilizados para el acondicionamiento de Meropenem 500mg P.P.S. en una Industria Farmacéutica, Lima 2018info:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalQuímico FarmacéuticoFarmaciaUniversidad Nacional de Trujillo.Facultad de Farmacia y BioquímicaORIGINALCalderon Piminchumo Dennis Alberto.pdfCalderon Piminchumo Dennis Alberto.pdfapplication/pdf1723565https://dspace.unitru.edu.pe/bitstreams/80227f48-3391-441c-8495-c556392ffbc8/downloade164cc5ef3f0407ac702b6710299318fMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/84ae8432-05b8-40ae-9ab6-321d8fb8a381/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/14177oai:dspace.unitru.edu.pe:20.500.14414/141772019-10-02 13:44:27.556http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
score |
13.949926 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).