This project shows the methodology and the standards and specifications necessary for the Assessment and Redesign (reinforcement ) of the structural tower of section square and self -supported of H=71.00m in height, to support additional burdens on existing along its structure , which it is located...

Descripción completa

Detalles Bibliográficos
Autor: Silva Muñoz, Williams Orlando
Formato: tesis de grado
Fecha de Publicación:2016
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/3835
Enlace del recurso:https://hdl.handle.net/20.500.14414/3835
Nivel de acceso:acceso abierto
Materia:Estructura de torre autosoportada
id UNIT_bab6e84cf999338b47b3cc6099fbf1a7
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/3835
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_ES.fl_str_mv “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
title “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
spellingShingle “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
Silva Muñoz, Williams Orlando
Estructura de torre autosoportada
title_short “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
title_full “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
title_fullStr “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
title_full_unstemmed “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
title_sort “rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.
author Silva Muñoz, Williams Orlando
author_facet Silva Muñoz, Williams Orlando
author_role author
dc.contributor.advisor.fl_str_mv Azabache Vásquez, Eduardo
dc.contributor.author.fl_str_mv Silva Muñoz, Williams Orlando
dc.subject.es_ES.fl_str_mv Estructura de torre autosoportada
topic Estructura de torre autosoportada
description This project shows the methodology and the standards and specifications necessary for the Assessment and Redesign (reinforcement ) of the structural tower of section square and self -supported of H=71.00m in height, to support additional burdens on existing along its structure , which it is located in the 0101711_PI_EL_ALTO station in El Alto Province and Department of Piura . An assessment of the current state of the tower took place on stage with the existing loads with the data obtained during the visit to the station where the tower is located. Then in the scenario of existing loads more future loads and subsequently performed the analysis of the proposed redesign on stage of existing loads more the loads future. MsTower V6.0 software is used as a tool for calculation and analysis of the project, considering the American code for telecommunication towers TIA-222F (Allowable Stress Design ASD), the specifications of the American Institute of Steel Construction (AISC) and the National Building Regulation (RNE) from Peru. Which they consider the forces produced on the structure are mainly caused by the wind and further that the wind does not occur simultaneously with the earthquake, being wind action which prevails over the action of the earthquake for this type structures. Therefore for our study is not considered the action of earthquake. It was determined that the structure of the tower in its current state with the existing loads should fail resistance of materials according to current standards and codes, and it was also determined that the structure of the tower in its current state with existing loads more future loads, should fail resistance and exceeds the maximum angular displacements according to the rules and codes. It is concluded that the structure needs strengthening and a proposal was made to redesign the tower to support existing and future loads, and thus present no resistance faults in its entirety and not to exceed the limits of maximum angular displacements according standards and codes. Finally the calculation of measures of the new elements of the redesign was conducted, as well as costs and budget for the project .
publishDate 2016
dc.date.accessioned.none.fl_str_mv 10/20/2016 8:14
dc.date.available.none.fl_str_mv 10/20/2016 8:14
dc.date.issued.fl_str_mv 2016
dc.type.es_ES.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/3835
url https://hdl.handle.net/20.500.14414/3835
dc.language.iso.es_ES.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.relation.ispartofseries.none.fl_str_mv TMEC 9149;9149
dc.rights.es_ES.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.none.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.none.fl_str_mv Universidad Nacional de Trujillo
publisher.none.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_ES.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/028d6eb2-d4fe-4172-8875-1f56605ead51/download
https://dspace.unitru.edu.pe/bitstreams/ae1178ef-bff7-44e2-abbc-8b10d44fddb9/download
bitstream.checksum.fl_str_mv 2408e8110f39a8838c6d1352f3fa75a6
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807290189673922560
spelling Azabache Vásquez, EduardoSilva Muñoz, Williams Orlando10/20/2016 8:1410/20/2016 8:142016https://hdl.handle.net/20.500.14414/3835This project shows the methodology and the standards and specifications necessary for the Assessment and Redesign (reinforcement ) of the structural tower of section square and self -supported of H=71.00m in height, to support additional burdens on existing along its structure , which it is located in the 0101711_PI_EL_ALTO station in El Alto Province and Department of Piura . An assessment of the current state of the tower took place on stage with the existing loads with the data obtained during the visit to the station where the tower is located. Then in the scenario of existing loads more future loads and subsequently performed the analysis of the proposed redesign on stage of existing loads more the loads future. MsTower V6.0 software is used as a tool for calculation and analysis of the project, considering the American code for telecommunication towers TIA-222F (Allowable Stress Design ASD), the specifications of the American Institute of Steel Construction (AISC) and the National Building Regulation (RNE) from Peru. Which they consider the forces produced on the structure are mainly caused by the wind and further that the wind does not occur simultaneously with the earthquake, being wind action which prevails over the action of the earthquake for this type structures. Therefore for our study is not considered the action of earthquake. It was determined that the structure of the tower in its current state with the existing loads should fail resistance of materials according to current standards and codes, and it was also determined that the structure of the tower in its current state with existing loads more future loads, should fail resistance and exceeds the maximum angular displacements according to the rules and codes. It is concluded that the structure needs strengthening and a proposal was made to redesign the tower to support existing and future loads, and thus present no resistance faults in its entirety and not to exceed the limits of maximum angular displacements according standards and codes. Finally the calculation of measures of the new elements of the redesign was conducted, as well as costs and budget for the project .Este presente proyecto muestra una metodología, así como las Normas y Especificaciones necesarias para la Evaluación y Rediseño (Reforzamiento) estructural de la Torre cuadrada autosoportada de H=71.00 m de altura para que soporte cargas adicionales a las existentes a lo largo de su estructura, y que se encuentra ubicada en la estación 0101711_PI_EL_ALTO, en la Provincia EL Alto, y Departamento de Piura. Se realizó una evaluación del estado actual de la torre en el escenario con las cargas existentes con los datos obtenidos en la visita a la estación en donde se encuentra la torre en su estado actual . Luego en el escenario de cargas existentes más las cargas futuras propuestas y posteriormente el análisis del rediseño que se propone en el escenario con cargas existentes más las cargas futuras. Se utilizó como herramienta de cálculo y análisis el software Ms tower V6.0, teniendo en cuenta la norma americana para Torres de Telecomunicación TIA-222F (Método de Esfuerzos Admisibles ASD), las especificaciones del American Institute of Steel Construction AISC y el Reglamento Nacional de Edificaciones RNE del Perú. Las cuales consideran que las fuerzas producidas sobre la estructura son provocadas principalmente por la acción del viento y además que la acción del viento no se produce de manera simultánea con el sismo, siendo la acción del viento la que predomina sobre la acción del sismo para este tipo de estructuras. Por lo tanto para nuestro estudio no se considera la acción del sismo. Se determinó que la estructura de la Torre en su estado actual con las cargas existentes falla por resistencia según las normas y códigos vigentes, así como también se determinó que la que la estructura de la Torre en su estado actual con las cargas existentes más las cargas futuras falla por resistencia y supera los límites máximos de desplazamientos angulares según las normas y códigos vigentes. Se concluye que la estructura necesita un reforzamiento y se realizó una propuesta de rediseño para que la torre soporte las cargas existentes y las cargas futuras y además para que la torre no presente fallas por resistencia en sus elementos, así como no supere los límites de desplazamientos angulares máximo según las normas y códigos vigentes. Por último se realizó el metrado de elementos nuevos que conforman el rediseño, así como también los costos y el presupuesto para la realización del proyecto.spaUniversidad Nacional de TrujilloTMEC 9149;9149SUNEDUinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUEstructura de torre autosoportada“rediseño de la estructura de la torre autosoportada de h=71m para que soporte las antenas de radiofrecuencia y microondas existentes, y 06 antenas de microondas futuras ubicada en la estación 0101711_pi_el_alto, piura”.info:eu-repo/semantics/bachelorThesisTítulo ProfesionalIngeniero MecánicoMecánicaUniversidad Nacional de Trujillo.Facultad de IngenieríaORIGINALSILVA MUÑOZ, WILLIAMS ORLANDO.pdfSILVA MUÑOZ, WILLIAMS ORLANDO.pdfESTRUCTURA DE TORRE AUTOSOPORTADAapplication/pdf6695153https://dspace.unitru.edu.pe/bitstreams/028d6eb2-d4fe-4172-8875-1f56605ead51/download2408e8110f39a8838c6d1352f3fa75a6MD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/ae1178ef-bff7-44e2-abbc-8b10d44fddb9/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/3835oai:dspace.unitru.edu.pe:20.500.14414/38352024-04-21 13:06:18.049http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.958958
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).