EFECTOS DE LOS TRATAMIENTOS TERMICOS APLICADOS AL ACERO ASTM A182, SOBRE EL DESGASTE DESLIZANTE SECO, BAJO DISTINTAS CONDICIONES DE ENSAYO Y SU RELACION CON LA MICROESTRUCTURA

Descripción del Articulo

The effect of the thermal treatments applied to the ASTM A182 steel, in relation to the dry sliding wear, was investigated under different test conditions: load and time. The purpose was to find the conditions to achieve the least wear. Fifty four (54) test specimens will be made for wear tests, acc...

Descripción completa

Detalles Bibliográficos
Autor: Avalos Collantes, Lander Isidro
Formato: tesis de grado
Fecha de Publicación:2017
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/9269
Enlace del recurso:https://hdl.handle.net/20.500.14414/9269
Nivel de acceso:acceso abierto
Materia:Tratamientos termicos aplicados al cero
Descripción
Sumario:The effect of the thermal treatments applied to the ASTM A182 steel, in relation to the dry sliding wear, was investigated under different test conditions: load and time. The purpose was to find the conditions to achieve the least wear. Fifty four (54) test specimens will be made for wear tests, according to ASTM D2782. Then, they were divided into three equal lots and the treatments were performed: quenching, annealing and normalizing. All samples were austenized at 1050 °C for 30 min. For quenching the cooling was in water. For the normalized, they were cooled in the air and for the annealing a slow cooling in the oven was done. All treatments were done in the Thermolyne muffle furnace. Hardness tests were performed on the IDENTEC digital durometer and the Rockwell C scale measurements. Wear tests were carried out on the MHASA Lathe by adapting the Amsler type device, using the ring-on-block configuration. The tests were run with three different load variations: 30N, 50N and 100N, at a constant speed of 250 rpm, and the test times were: 10', 20'30'40'50'60' (min). The wear measurements were made in μm. Microscopy was performed at the optical level using the ZEISS 1000X microscope.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).