Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017
Descripción del Articulo
This report of pre-professional practices entitled: Physico-chemical control of amoxicillin 875 mg + clavulanic acid 125 mg coated tablet made in a National Pharmaceutical Laboratory, 2016-2017, was carried out with the objective of determining whether physicochemical control trials of amoxicillin 8...
Autor: | |
---|---|
Formato: | tesis de grado |
Fecha de Publicación: | 2018 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | UNITRU-Tesis |
Lenguaje: | español |
OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/11143 |
Enlace del recurso: | https://hdl.handle.net/20.500.14414/11143 |
Nivel de acceso: | acceso abierto |
Materia: | control fisicoquímico amoxicilina ácido clavulánico UHPLC |
id |
UNIT_922d558aaf6dcc2c8ccbc7e47b9c542c |
---|---|
oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/11143 |
network_acronym_str |
UNIT |
network_name_str |
UNITRU-Tesis |
repository_id_str |
4801 |
dc.title.es_PE.fl_str_mv |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 |
title |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 |
spellingShingle |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 Miranda Lopez, Carlos Ausberto control fisicoquímico amoxicilina ácido clavulánico UHPLC |
title_short |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 |
title_full |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 |
title_fullStr |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 |
title_full_unstemmed |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 |
title_sort |
Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017 |
author |
Miranda Lopez, Carlos Ausberto |
author_facet |
Miranda Lopez, Carlos Ausberto |
author_role |
author |
dc.contributor.advisor.fl_str_mv |
Aro Díaz, Rubén Jesús |
dc.contributor.author.fl_str_mv |
Miranda Lopez, Carlos Ausberto |
dc.subject.es_PE.fl_str_mv |
control fisicoquímico amoxicilina ácido clavulánico UHPLC |
topic |
control fisicoquímico amoxicilina ácido clavulánico UHPLC |
description |
This report of pre-professional practices entitled: Physico-chemical control of amoxicillin 875 mg + clavulanic acid 125 mg coated tablet made in a National Pharmaceutical Laboratory, 2016-2017, was carried out with the objective of determining whether physicochemical control trials of amoxicillin 875 mg + clavulanic acid 125 mg coated tablet from a national pharmaceutical laboratory, meet the specifications according to their analytical technique. The sample consisted of 60 tablets of five batches. The physicochemical control of the samples was carried out according to the analytical technique of the laboratory during the pre-professional practices, which includes own methodologies, from the Pharmacopeia of the United States of America (USP 39-NF 31) and the British Pharmacopoeia (BP 2016) . The tests carried out were: description, uniformity of weight, water-Karl Fischer, identification and measurement by ultrahigh-resolution liquid chromatography (UHPLC), uniformity of dosage units and dissolution. It is concluded that amoxicillin 875 mg + clavulanic acid 125 mg coated tablet meets the specifications established in the analytical technique |
publishDate |
2018 |
dc.date.accessioned.none.fl_str_mv |
2018-12-31T19:06:24Z |
dc.date.available.none.fl_str_mv |
2018-12-31T19:06:24Z |
dc.date.issued.fl_str_mv |
2018 |
dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
format |
bachelorThesis |
dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/11143 |
url |
https://hdl.handle.net/20.500.14414/11143 |
dc.language.iso.es_PE.fl_str_mv |
spa |
language |
spa |
dc.relation.ispartof.fl_str_mv |
SUNEDU |
dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
eu_rights_str_mv |
openAccess |
rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio Institucional - UNITRU |
dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
UNITRU-Tesis |
collection |
UNITRU-Tesis |
bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/c7a874a9-1350-4241-a75e-2a6e464c76d1/download https://dspace.unitru.edu.pe/bitstreams/dcc8a536-fcdd-47ab-9877-b8d2d602f31a/download |
bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 ee044e4da666cac84ba467fd757feede |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
_version_ |
1807290240164954112 |
spelling |
Aro Díaz, Rubén JesúsMiranda Lopez, Carlos Ausberto2018-12-31T19:06:24Z2018-12-31T19:06:24Z2018https://hdl.handle.net/20.500.14414/11143This report of pre-professional practices entitled: Physico-chemical control of amoxicillin 875 mg + clavulanic acid 125 mg coated tablet made in a National Pharmaceutical Laboratory, 2016-2017, was carried out with the objective of determining whether physicochemical control trials of amoxicillin 875 mg + clavulanic acid 125 mg coated tablet from a national pharmaceutical laboratory, meet the specifications according to their analytical technique. The sample consisted of 60 tablets of five batches. The physicochemical control of the samples was carried out according to the analytical technique of the laboratory during the pre-professional practices, which includes own methodologies, from the Pharmacopeia of the United States of America (USP 39-NF 31) and the British Pharmacopoeia (BP 2016) . The tests carried out were: description, uniformity of weight, water-Karl Fischer, identification and measurement by ultrahigh-resolution liquid chromatography (UHPLC), uniformity of dosage units and dissolution. It is concluded that amoxicillin 875 mg + clavulanic acid 125 mg coated tablet meets the specifications established in the analytical techniqueEl presente informe de prácticas pre-profesionales titulado: Control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017, fue realizado con el objetivo de determinar si los ensayos de control fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta de un laboratorio farmacéutico nacional, cumplen con las especificaciones según su técnica analítica. La muestra estuvo conformada por 60 tabletas de cinco lotes. El control fisicoquímico de las muestras se realizó según técnica analítica del laboratorio durante las prácticas pre-profesionales, la cual comprende metodologías propias, de la Farmacopea de los Estados Unidos de América (USP 39-NF 31) y de Farmacopea Británica (BP 2016). Los ensayos realizados fueron: descripción, uniformidad de peso, agua- Karl Fischer, identificación y dosaje mediante cromatografía líquida de ultra alta resolución (UHPLC), uniformidad de unidades de dosificación y disolución. Se concluye que amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta cumple con las especificaciones establecidas en la técnica analíticaTesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio Institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUcontrol fisicoquímicoamoxicilinaácido clavulánicoUHPLCControl fisicoquímico de amoxicilina 875 mg + ácido clavulánico 125 mg tableta recubierta realizado en un Laboratorio Farmacéutico Nacional, 2016-2017info:eu-repo/semantics/bachelorThesisSUNEDUTítulo ProfesionalQuímico FarmacéuticoFarmaciaUniversidad Nacional de Trujillo.Facultad de Farmacia y BioquímicaLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/c7a874a9-1350-4241-a75e-2a6e464c76d1/download8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALMiranda Lopez Carlos Ausberto-convertido.pdfMiranda Lopez Carlos Ausberto-convertido.pdfapplication/pdf618727https://dspace.unitru.edu.pe/bitstreams/dcc8a536-fcdd-47ab-9877-b8d2d602f31a/downloadee044e4da666cac84ba467fd757feedeMD5320.500.14414/11143oai:dspace.unitru.edu.pe:20.500.14414/111432019-07-04 11:54:19.615http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
score |
13.95948 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).