Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo

Descripción del Articulo

In the present assay it was investigated if method ELISA for the determination of prostate specific antigen (PSA) employee in the Quintanilla Laboratory S.R.L. fulfills the validation criteria. For this the following parameters were evaluated: linearity, precision (repeatability and reproducibility)...

Descripción completa

Detalles Bibliográficos
Autores: Valencia Valera, Daniel Antonio, Vásquez Chávez, Paúl
Formato: tesis de grado
Fecha de Publicación:2006
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/3320
Enlace del recurso:https://hdl.handle.net/20.500.14414/3320
Nivel de acceso:acceso abierto
Materia:Ape, Reproducibilidad, Exactitud, Elisa, Validación, Linealidad, Robustez, Repetibilidad, Precisión
id UNIT_6f5cc96089f482afca46f0b8b1c2fddb
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/3320
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_ES.fl_str_mv Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
title Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
spellingShingle Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
Valencia Valera, Daniel Antonio
Ape, Reproducibilidad, Exactitud, Elisa, Validación, Linealidad, Robustez, Repetibilidad, Precisión
title_short Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
title_full Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
title_fullStr Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
title_full_unstemmed Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
title_sort Validación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujillo
author Valencia Valera, Daniel Antonio
author_facet Valencia Valera, Daniel Antonio
Vásquez Chávez, Paúl
author_role author
author2 Vásquez Chávez, Paúl
author2_role author
dc.contributor.advisor.fl_str_mv Alva Plasencia, Pedro Marcelo
Castro Guzmán, Judith
dc.contributor.author.fl_str_mv Valencia Valera, Daniel Antonio
Vásquez Chávez, Paúl
dc.subject.es_ES.fl_str_mv Ape, Reproducibilidad, Exactitud, Elisa, Validación, Linealidad, Robustez, Repetibilidad, Precisión
topic Ape, Reproducibilidad, Exactitud, Elisa, Validación, Linealidad, Robustez, Repetibilidad, Precisión
description In the present assay it was investigated if method ELISA for the determination of prostate specific antigen (PSA) employee in the Quintanilla Laboratory S.R.L. fulfills the validation criteria. For this the following parameters were evaluated: linearity, precision (repeatability and reproducibility), exactitude, detection and quantification limits and robustness, which were determined according to the established by the Spaniard Association of Pharmacists of the Industry and following the procedures described in the inserted of kit of reagents provided by the manufacturer "DIAGNOSTIC AUTOMATION INC". The results of the study show us that the calibration chart was linear with a correlation coefficient equal to 0.998; the statistical test of the slope confirmed the linearity. The variation coefficient in repeatability assay was 4.604% and in the case of the reproducibility assay it was 4,432%. The exactitude of the method was demonstrated after applying the t-student test with 95% of confidence and 8 degrees of freedom and obtaining a t - experimental value (1.541) smaller to t – distribution table value (2.306). The detection and quantification limits were 0,272ng/mL and 0,908ng/mL respectively. The method turned out to be robustness to the variation of analysts and ends for micropipettes more do not to the case of temperature variation. This way, is demonstrated that the method fulfills the validation criteria
publishDate 2006
dc.date.accessioned.none.fl_str_mv 2016-10-13T22:06:13Z
dc.date.available.none.fl_str_mv 2016-10-13T22:06:13Z
dc.date.issued.fl_str_mv 2006
dc.type.es_ES.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/3320
url https://hdl.handle.net/20.500.14414/3320
dc.language.iso.es_ES.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.none.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.none.fl_str_mv Universidad Nacional de Trujillo
publisher.none.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_ES.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/20dd7357-885c-4f56-85a4-33db96dbc819/download
https://dspace.unitru.edu.pe/bitstreams/93ab55d3-44bb-44a3-aaa7-0dc4424e5138/download
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
b1a0e9f1321f4db18ae70f92523e1a28
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807290163581157376
spelling Alva Plasencia, Pedro MarceloCastro Guzmán, JudithValencia Valera, Daniel AntonioVásquez Chávez, Paúl2016-10-13T22:06:13Z2016-10-13T22:06:13Z2006https://hdl.handle.net/20.500.14414/3320In the present assay it was investigated if method ELISA for the determination of prostate specific antigen (PSA) employee in the Quintanilla Laboratory S.R.L. fulfills the validation criteria. For this the following parameters were evaluated: linearity, precision (repeatability and reproducibility), exactitude, detection and quantification limits and robustness, which were determined according to the established by the Spaniard Association of Pharmacists of the Industry and following the procedures described in the inserted of kit of reagents provided by the manufacturer "DIAGNOSTIC AUTOMATION INC". The results of the study show us that the calibration chart was linear with a correlation coefficient equal to 0.998; the statistical test of the slope confirmed the linearity. The variation coefficient in repeatability assay was 4.604% and in the case of the reproducibility assay it was 4,432%. The exactitude of the method was demonstrated after applying the t-student test with 95% of confidence and 8 degrees of freedom and obtaining a t - experimental value (1.541) smaller to t – distribution table value (2.306). The detection and quantification limits were 0,272ng/mL and 0,908ng/mL respectively. The method turned out to be robustness to the variation of analysts and ends for micropipettes more do not to the case of temperature variation. This way, is demonstrated that the method fulfills the validation criteriaEn el presente trabajo se investigó si el método ELISA para la determinación de antígeno prostático específico (APE) empleado en el Laboratorio Quintanilla S.R.L. cumple con los criterios de validación. Para esto se evaluaron los siguientes parámetros: linealidad, precisión (repetibilidad y reproduciblilidad), exactitud, límite de detección, límite de cuantificación y robustez, los cuales fueron determinados de acuerdo a lo establecido por la Asociación Española de Farmacéuticos de la Industria y siguiendo los procedimientos descritos en el inserto del kit de reactivos provisto por el fabricante “DIAGNOSTIC AUTOMATION INC.” Los resultados del estudio nos muestran que la curva de calibración fue lineal con un coeficiente de correlación igual a 0.998; la prueba estadística de la pendiente confirmó la linealidad. El coeficiente de variación en el estudio de la repetibilidad fue igual a 4,604 % y en el caso de la reproducibilidad fue de 4,432%. La exactitud del método quedó demostrada luego de aplicar el test t-student con el 95% de confianza y 8 grados de libertad y obtener un t experimental (1.541) menor al t de tablas (2.306). Los límites de detección y cuantificación fueron 0.272 ng/mL y 0.908 ng/mL respectivamente. El método resultó ser robusto ante la variación de analistas y puntas para micropipetas más no para el caso de variación de temperatura. De esta manera, se demostró que el método cumple con los criterios de validación.spaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUApe, Reproducibilidad, Exactitud, Elisa, Validación, Linealidad, Robustez, Repetibilidad, PrecisiónValidación del método elisa para la determinación cuantitativa de antígeno prostático específico como prueba diagnóstica en el laboratorio Quintanilla S.R.L. de la ciudad de Trujilloinfo:eu-repo/semantics/bachelorThesisSUNEDUBachillerQuímico FarmacéuticoFarmaciaUniversidad Nacional de Trujillo.Facultad de Farmacia y BioquimicaLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/20dd7357-885c-4f56-85a4-33db96dbc819/download8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALValencia Valera, Daniel Antonio.pdfValencia Valera, Daniel Antonio.pdfapplication/pdf1220448https://dspace.unitru.edu.pe/bitstreams/93ab55d3-44bb-44a3-aaa7-0dc4424e5138/downloadb1a0e9f1321f4db18ae70f92523e1a28MD5120.500.14414/3320oai:dspace.unitru.edu.pe:20.500.14414/33202017-11-15 12:18:37.763http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.958958
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).