Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima
Descripción del Articulo
In order to evaluate water availability River Basin Bath (Lima, Peru) for the expansion of the electric power of the Tingo Hydroelectric born the proposed expansion, which is to capture all the water of the river Bathrooms under the current hydraulic diagram of Hydroelectric Tingo, ie expand the cap...
| Autores: | , |
|---|---|
| Formato: | tesis de grado |
| Fecha de Publicación: | 2014 |
| Institución: | Universidad Nacional de Trujillo |
| Repositorio: | UNITRU-Tesis |
| Lenguaje: | español |
| OAI Identifier: | oai:dspace.unitru.edu.pe:20.500.14414/7547 |
| Enlace del recurso: | https://hdl.handle.net/20.500.14414/7547 |
| Nivel de acceso: | acceso abierto |
| Materia: | Estudio hidrológico, central hidroeléctrica, potencia |
| id |
UNIT_62056216816a9d224a08404d9eb19b0d |
|---|---|
| oai_identifier_str |
oai:dspace.unitru.edu.pe:20.500.14414/7547 |
| network_acronym_str |
UNIT |
| network_name_str |
UNITRU-Tesis |
| repository_id_str |
4801 |
| dc.title.es_PE.fl_str_mv |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima |
| title |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima |
| spellingShingle |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima López García, Henry David. Estudio hidrológico, central hidroeléctrica, potencia |
| title_short |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima |
| title_full |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima |
| title_fullStr |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima |
| title_full_unstemmed |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima |
| title_sort |
Estudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Lima |
| author |
López García, Henry David. |
| author_facet |
López García, Henry David. Alayo Ruiz, Francis Brander |
| author_role |
author |
| author2 |
Alayo Ruiz, Francis Brander |
| author2_role |
author |
| dc.contributor.advisor.fl_str_mv |
Paz Vergara Pérez, Juan Emilio |
| dc.contributor.author.fl_str_mv |
López García, Henry David. Alayo Ruiz, Francis Brander |
| dc.subject.es_PE.fl_str_mv |
Estudio hidrológico, central hidroeléctrica, potencia |
| topic |
Estudio hidrológico, central hidroeléctrica, potencia |
| description |
In order to evaluate water availability River Basin Bath (Lima, Peru) for the expansion of the electric power of the Tingo Hydroelectric born the proposed expansion, which is to capture all the water of the river Bathrooms under the current hydraulic diagram of Hydroelectric Tingo, ie expand the capacity of the hydraulic infrastructure (Intake, Sand Trap, Canal driving, forebay tank, pipe pressure, etc.), according to the design flow and the water availability subject of this survey. Of generated synthetic series, we have obtained the mean monthly flows, which will be used for the design of the elements of the Enlargement of the Tingo Hydroelectric. A consequence of the results of the current hydrological study, the value of the design flow for the expansion of the plant is 2.5 m3 / s, maintaining the existing hydraulic jump, which could generate power is 8.8 MW. Also, the value of the maximum rainfall for a return period of 50 years is 51.7 mm with a maximum flow of avenues 67.0 m3 / s is calculated, the flow will determine the height of the protective walls of the structures capture and conveyance. Under this scheme the description of the construction and / or modification of their components will be expanded |
| publishDate |
2014 |
| dc.date.accessioned.none.fl_str_mv |
2017-05-03T17:07:06Z |
| dc.date.available.none.fl_str_mv |
2017-05-03T17:07:06Z |
| dc.date.issued.fl_str_mv |
2014 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
| format |
bachelorThesis |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.14414/7547 |
| url |
https://hdl.handle.net/20.500.14414/7547 |
| dc.language.iso.es_PE.fl_str_mv |
spa |
| language |
spa |
| dc.relation.ispartof.fl_str_mv |
SUNEDU |
| dc.relation.ispartofseries.none.fl_str_mv |
TAGC;119 |
| dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.es_PE.fl_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/2.5/pe/ |
| dc.publisher.es_PE.fl_str_mv |
Universidad Nacional de Trujillo |
| dc.source.es_PE.fl_str_mv |
Universidad Nacional de Trujillo Repositorio institucional - UNITRU |
| dc.source.none.fl_str_mv |
reponame:UNITRU-Tesis instname:Universidad Nacional de Trujillo instacron:UNITRU |
| instname_str |
Universidad Nacional de Trujillo |
| instacron_str |
UNITRU |
| institution |
UNITRU |
| reponame_str |
UNITRU-Tesis |
| collection |
UNITRU-Tesis |
| bitstream.url.fl_str_mv |
https://dspace.unitru.edu.pe/bitstreams/795f2e23-1af8-4b89-8a6b-62bde03cc4f1/download https://dspace.unitru.edu.pe/bitstreams/86449615-b50a-48a6-9e5e-dd8c601ce210/download |
| bitstream.checksum.fl_str_mv |
16b5f61e7c7f16f22fb2e438aeb1f8aa 8a4605be74aa9ea9d79846c1fba20a33 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Institucional - UNITRU |
| repository.mail.fl_str_mv |
repositorios@unitru.edu.pe |
| _version_ |
1807290020954898432 |
| spelling |
Paz Vergara Pérez, Juan EmilioLópez García, Henry David.Alayo Ruiz, Francis Brander2017-05-03T17:07:06Z2017-05-03T17:07:06Z2014https://hdl.handle.net/20.500.14414/7547In order to evaluate water availability River Basin Bath (Lima, Peru) for the expansion of the electric power of the Tingo Hydroelectric born the proposed expansion, which is to capture all the water of the river Bathrooms under the current hydraulic diagram of Hydroelectric Tingo, ie expand the capacity of the hydraulic infrastructure (Intake, Sand Trap, Canal driving, forebay tank, pipe pressure, etc.), according to the design flow and the water availability subject of this survey. Of generated synthetic series, we have obtained the mean monthly flows, which will be used for the design of the elements of the Enlargement of the Tingo Hydroelectric. A consequence of the results of the current hydrological study, the value of the design flow for the expansion of the plant is 2.5 m3 / s, maintaining the existing hydraulic jump, which could generate power is 8.8 MW. Also, the value of the maximum rainfall for a return period of 50 years is 51.7 mm with a maximum flow of avenues 67.0 m3 / s is calculated, the flow will determine the height of the protective walls of the structures capture and conveyance. Under this scheme the description of the construction and / or modification of their components will be expandedCon el propósito de evaluar las disponibilidades Hídricas de la Cuenca del Rio Baños (Lima, Perú) para la ampliación de la potencia eléctrica de la Central Hidroeléctrica Tingo, nace la propuesta de la ampliación, la cual consiste en captar toda el agua del río Baños, bajo el actual esquema hidráulico de la Central Hidroeléctrica Tingo, es decir ampliar la capacidad de la infraestructura hidráulica (Bocatoma, Desarenador, Canal de conducción, Cámara de Carga, tubería de Presión, etc.), según el caudal de diseño, y la disponibilidad hídrica objeto del presente Estudio. De las series sintéticas generadas, se han obtenido los caudales medios mensuales, que será usado para el diseño de los elementos de la Ampliación de la Central Hidroeléctrica Tingo. A consecuencia de los resultados del estudio hidrológico actual, el valor del caudal de diseño para la ampliación de la central es de 2.5 m3/seg, manteniendo el salto hidráulico existente, la potencia que podría generar es 8.8 MW. Así también, el valor de la precipitación máxima para un periodo de retorno de 50 años es de 51.7 mm con lo que se calcula un caudal máximo de avenidas de 67.0 m3/s, cuyo caudal determinará la altura de los muros de protección de las estructuras de captación y conducción. Bajo este esquema se realizará la descripción de la construcción y/o modificación de sus componentes de ampliaciónTesisspaUniversidad Nacional de TrujilloTAGC;119SUNEDUinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUEstudio hidrológico, central hidroeléctrica, potenciaEstudio Hidrológico Cuenca Chancay – Huaral, para ampliar la potencia de la Central Hidroeléctrica Tingo, de 1.2 MW a 8.8 MW en la Provincia de Huaral - Limainfo:eu-repo/semantics/bachelorThesisTítulo ProfesionalIngeniero AgrícolaAgricolaUniversidad Nacional de Trujillo. Facultad de Ciencias AgropecuariasORIGINALLÓPEZ GARCÍA-ALAYO RUIZ.pdfLÓPEZ GARCÍA-ALAYO RUIZ.pdfapplication/pdf2559642https://dspace.unitru.edu.pe/bitstreams/795f2e23-1af8-4b89-8a6b-62bde03cc4f1/download16b5f61e7c7f16f22fb2e438aeb1f8aaMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/86449615-b50a-48a6-9e5e-dd8c601ce210/download8a4605be74aa9ea9d79846c1fba20a33MD5220.500.14414/7547oai:dspace.unitru.edu.pe:20.500.14414/75472024-05-24 12:20:05.791http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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 |
| score |
13.9061165 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).