Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016

Descripción del Articulo

Abstract Introduction: The present study aims to compare the quantification of glucose by colorimetric and digital glucometry, used for the blood glucose self-monitoring, in diabetic patients from Iquitos between July 2015 and January of 2016. Through parameters such as accuracy, precision and linea...

Descripción completa

Detalles Bibliográficos
Autor: Perea Vargas, Rosa María
Formato: tesis de maestría
Fecha de Publicación:2018
Institución:Universidad Nacional de Trujillo
Repositorio:UNITRU-Tesis
Lenguaje:español
OAI Identifier:oai:dspace.unitru.edu.pe:20.500.14414/11825
Enlace del recurso:https://hdl.handle.net/20.500.14414/11825
Nivel de acceso:acceso abierto
Materia:Automonitorización de la glucosa sanguínea
Exactitud
Precisión
id UNIT_21322f2d8b31af7f0b6144bf230dedf9
oai_identifier_str oai:dspace.unitru.edu.pe:20.500.14414/11825
network_acronym_str UNIT
network_name_str UNITRU-Tesis
repository_id_str 4801
dc.title.es_PE.fl_str_mv Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
title Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
spellingShingle Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
Perea Vargas, Rosa María
Automonitorización de la glucosa sanguínea
Exactitud
Precisión
title_short Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
title_full Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
title_fullStr Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
title_full_unstemmed Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
title_sort Comparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016
author Perea Vargas, Rosa María
author_facet Perea Vargas, Rosa María
author_role author
dc.contributor.advisor.fl_str_mv Arbayza Fructuoso, Juan Delfín
dc.contributor.author.fl_str_mv Perea Vargas, Rosa María
dc.subject.es_PE.fl_str_mv Automonitorización de la glucosa sanguínea
Exactitud
Precisión
topic Automonitorización de la glucosa sanguínea
Exactitud
Precisión
description Abstract Introduction: The present study aims to compare the quantification of glucose by colorimetric and digital glucometry, used for the blood glucose self-monitoring, in diabetic patients from Iquitos between July 2015 and January of 2016. Through parameters such as accuracy, precision and linearity of both methods. Methods: The glucose was measured in capillary by a digital glucometer (Accu-chek®) and the reference method (colorimetry) respectively. The accuracy, precision and linearity of both methods was determined. Results: Accuracy (r = 0.963 and R2 = 0.928), precision (variation = 7.61%, 4.52%; digital and colorimetric glucose measurement respectively) and linearity (R2 = 0.998 in both methods) were determined. Conclusion: The slope is same in the digital method (y = 7.36 + 0.96 * x) than the colorimeter method (y = 0.19 + 0.99 * x).
publishDate 2018
dc.date.accessioned.none.fl_str_mv 2019-02-28T19:58:31Z
dc.date.available.none.fl_str_mv 2019-02-28T19:58:31Z
dc.date.issued.fl_str_mv 2018
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.14414/11825
url https://hdl.handle.net/20.500.14414/11825
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/2.5/pe/
dc.publisher.es_PE.fl_str_mv Universidad Nacional de Trujillo
dc.source.es_PE.fl_str_mv Universidad Nacional de Trujillo
Repositorio institucional - UNITRU
dc.source.none.fl_str_mv reponame:UNITRU-Tesis
instname:Universidad Nacional de Trujillo
instacron:UNITRU
instname_str Universidad Nacional de Trujillo
instacron_str UNITRU
institution UNITRU
reponame_str UNITRU-Tesis
collection UNITRU-Tesis
bitstream.url.fl_str_mv https://dspace.unitru.edu.pe/bitstreams/e0e3692f-712e-4437-8069-34e486cd0776/download
https://dspace.unitru.edu.pe/bitstreams/7ce82596-3552-4e86-8c00-09581dd710e1/download
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
d25b3cb73b6259bf07b4239d80e6ab08
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Institucional - UNITRU
repository.mail.fl_str_mv repositorios@unitru.edu.pe
_version_ 1807290165992882176
spelling Arbayza Fructuoso, Juan DelfínPerea Vargas, Rosa María2019-02-28T19:58:31Z2019-02-28T19:58:31Z2018https://hdl.handle.net/20.500.14414/11825Abstract Introduction: The present study aims to compare the quantification of glucose by colorimetric and digital glucometry, used for the blood glucose self-monitoring, in diabetic patients from Iquitos between July 2015 and January of 2016. Through parameters such as accuracy, precision and linearity of both methods. Methods: The glucose was measured in capillary by a digital glucometer (Accu-chek®) and the reference method (colorimetry) respectively. The accuracy, precision and linearity of both methods was determined. Results: Accuracy (r = 0.963 and R2 = 0.928), precision (variation = 7.61%, 4.52%; digital and colorimetric glucose measurement respectively) and linearity (R2 = 0.998 in both methods) were determined. Conclusion: The slope is same in the digital method (y = 7.36 + 0.96 * x) than the colorimeter method (y = 0.19 + 0.99 * x).Resumen Introducción: El presente trabajo tuvo como finalidad comparar la cuantificación de la glucosa mediante la glucometría colorimétrica y la digital, usada para la automonitorización de la glucosa sanguínea, en pacientes diabéticos de la ciudad de Iquitos, entre Julio del 2015 y Enero del 2016. A través de parámetros como exactitud, precisión y linealidad de ambos métodos.Métodos: La cantidad de glucosa en sangre capilar se determinó usando un glucómetro digital (Accu-chek®) y con el método de referencia (glucosa oxidasa). comparando los parámetros antes mencionados de ambos métodos.Resultados: La exactitud (r=0,963 y un R2=0,928), precisión (variación = 7,61%, 4,52%; glucometría digital y colorimétrica respectivamente) y la linealidad (R2= 0,998) fue determinada en ambos métodos. Conclusión: La pendiente es similar en la glucometría digital (y=7,36+0,96*x) que en el colorímetro (y=0,19+0,99*x).TesisspaUniversidad Nacional de Trujilloinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/2.5/pe/Universidad Nacional de TrujilloRepositorio institucional - UNITRUreponame:UNITRU-Tesisinstname:Universidad Nacional de Trujilloinstacron:UNITRUAutomonitorización de la glucosa sanguíneaExactitudPrecisiónComparación entre la cuantificación de la Glucosa mediante la Glucometría Colorimétrica y la Glucometría Digital en pacientes Diabéticos, Iquitos, Julio-Enero 2016info:eu-repo/semantics/masterThesisSUNEDUMaestríaMaestra en Farmacia y BioquímicaMaestría en Farmacia y Bioquímica mención Farmacia ClínicaUniversidad Nacional de Trujillo.Escuela de PosgradoLICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://dspace.unitru.edu.pe/bitstreams/e0e3692f-712e-4437-8069-34e486cd0776/download8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALPerea Vargas Rosa María.pdfPerea Vargas Rosa María.pdfapplication/pdf1954354https://dspace.unitru.edu.pe/bitstreams/7ce82596-3552-4e86-8c00-09581dd710e1/downloadd25b3cb73b6259bf07b4239d80e6ab08MD5120.500.14414/11825oai:dspace.unitru.edu.pe:20.500.14414/118252019-02-28 14:58:31.615http://creativecommons.org/licenses/by-nc-nd/2.5/pe/info:eu-repo/semantics/openAccessopen.accesshttps://dspace.unitru.edu.peRepositorio Institucional - UNITRUrepositorios@unitru.edu.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
score 13.971837
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).