Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022

Descripción del Articulo

The thesis was developed in the Power Plant of the city of Requena, to analyze the evolution of the environmental parameters in its power plant from the environmental monitoring of 2018 -2021. The research is non-experimental, analytical, predictive, horizontal and retrospective. Data variations fro...

Descripción completa

Detalles Bibliográficos
Autor: Sangama Correa, Christian Manuel
Formato: tesis de grado
Fecha de Publicación:2022
Institución:Universidad Nacional De La Amazonía Peruana
Repositorio:UNAPIquitos-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unapiquitos.edu.pe:20.500.12737/8477
Enlace del recurso:https://hdl.handle.net/20.500.12737/8477
Nivel de acceso:acceso abierto
Materia:Parámetros
Ruido
Centrales eléctricas
Impacto ambiental
Zonas rurales
https://purl.org/pe-repo/ocde/ford#2.07.01
id UNAP_96366ef5b53d93e290b102f0d779115a
oai_identifier_str oai:repositorio.unapiquitos.edu.pe:20.500.12737/8477
network_acronym_str UNAP
network_name_str UNAPIquitos-Institucional
repository_id_str 4362
dc.title.es_PE.fl_str_mv Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
title Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
spellingShingle Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
Sangama Correa, Christian Manuel
Parámetros
Ruido
Centrales eléctricas
Impacto ambiental
Zonas rurales
https://purl.org/pe-repo/ocde/ford#2.07.01
title_short Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
title_full Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
title_fullStr Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
title_full_unstemmed Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
title_sort Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022
author Sangama Correa, Christian Manuel
author_facet Sangama Correa, Christian Manuel
author_role author
dc.contributor.advisor.fl_str_mv Gratelly Silva, Pedro Antonio
dc.contributor.author.fl_str_mv Sangama Correa, Christian Manuel
dc.subject.es_PE.fl_str_mv Parámetros
Ruido
Centrales eléctricas
Impacto ambiental
Zonas rurales
topic Parámetros
Ruido
Centrales eléctricas
Impacto ambiental
Zonas rurales
https://purl.org/pe-repo/ocde/ford#2.07.01
dc.subject.ocde.es_PE.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.07.01
description The thesis was developed in the Power Plant of the city of Requena, to analyze the evolution of the environmental parameters in its power plant from the environmental monitoring of 2018 -2021. The research is non-experimental, analytical, predictive, horizontal and retrospective. Data variations from 15 quarterly environmental monitoring (04 years) were systematized and analyzed, and based on this analysis of trends and prediction of changes in environmental parameters through mathematical modeling using the Holt-Winters Model with exponential smoothing. The results show that the noise in the Requena power plant has a decreasing trend and the noise levels comply with the environmental quality of the noise, which are not higher than 80 dB. The prediction analysis for the next year reports a descending noise evolution from a maximum level of 61.02 dB to a minimum level of 58.12 dB. In the electromagnetic field, it reports low values according to environmental quality standards for non-ionizing radiation, these values reached are much lower than the maximum level allowed of 4166.67 Volts, which is the maximum level of intensity of non-ionizing radiation. The forecast analysis reports an increasing evolution from a minimum level of 55.55 V/m to a maximum level of 71.07 V/m. Regarding air quality, the evolution of PM-10 particulate material reports values below the National Environmental Quality Standards for Air, which do not exceed 100 ug/m3. The forecast analysis reports a decreasing trend from a maximum level of 43.91 ug/m3 to a minimum level of 36.14 ug/m3.
publishDate 2022
dc.date.accessioned.none.fl_str_mv 2022-10-25T18:06:32Z
dc.date.available.none.fl_str_mv 2022-10-25T18:06:32Z
dc.date.issued.fl_str_mv 2022
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12737/8477
url https://hdl.handle.net/20.500.12737/8477
dc.language.iso.es_PE.fl_str_mv spa
language spa
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
dc.format.es_PE.fl_str_mv application/pdf
dc.publisher.es_PE.fl_str_mv Universidad Nacional de la Amazonía Peruana
dc.publisher.country.es_PE.fl_str_mv PE
dc.source.none.fl_str_mv reponame:UNAPIquitos-Institucional
instname:Universidad Nacional De La Amazonía Peruana
instacron:UNAPIquitos
instname_str Universidad Nacional De La Amazonía Peruana
instacron_str UNAPIquitos
institution UNAPIquitos
reponame_str UNAPIquitos-Institucional
collection UNAPIquitos-Institucional
bitstream.url.fl_str_mv https://repositorio.unapiquitos.edu.pe/bitstreams/4c10dade-ab2b-46ad-8ad6-30638f2efbb2/download
https://repositorio.unapiquitos.edu.pe/bitstreams/ee17f250-d7f6-4768-b568-d75be26dd641/download
https://repositorio.unapiquitos.edu.pe/bitstreams/b9460596-edeb-40ea-847b-9242d3367c9e/download
bitstream.checksum.fl_str_mv 11b7c35f3e53ccd9b88c93e1502ce56b
49426e0b335e33b2cb85164bfa083816
dd347bd359f5f147d7f80512e6f2cacf
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Digital UNAP
repository.mail.fl_str_mv repositorio.institucional@unapiquitos.edu.pe
_version_ 1846612660148240384
spelling Gratelly Silva, Pedro AntonioSangama Correa, Christian Manuel2022-10-25T18:06:32Z2022-10-25T18:06:32Z2022https://hdl.handle.net/20.500.12737/8477The thesis was developed in the Power Plant of the city of Requena, to analyze the evolution of the environmental parameters in its power plant from the environmental monitoring of 2018 -2021. The research is non-experimental, analytical, predictive, horizontal and retrospective. Data variations from 15 quarterly environmental monitoring (04 years) were systematized and analyzed, and based on this analysis of trends and prediction of changes in environmental parameters through mathematical modeling using the Holt-Winters Model with exponential smoothing. The results show that the noise in the Requena power plant has a decreasing trend and the noise levels comply with the environmental quality of the noise, which are not higher than 80 dB. The prediction analysis for the next year reports a descending noise evolution from a maximum level of 61.02 dB to a minimum level of 58.12 dB. In the electromagnetic field, it reports low values according to environmental quality standards for non-ionizing radiation, these values reached are much lower than the maximum level allowed of 4166.67 Volts, which is the maximum level of intensity of non-ionizing radiation. The forecast analysis reports an increasing evolution from a minimum level of 55.55 V/m to a maximum level of 71.07 V/m. Regarding air quality, the evolution of PM-10 particulate material reports values below the National Environmental Quality Standards for Air, which do not exceed 100 ug/m3. The forecast analysis reports a decreasing trend from a maximum level of 43.91 ug/m3 to a minimum level of 36.14 ug/m3.La tesis se desarrolló en la Central Eléctrica de la ciudad de Requena, para analizar la evolución de los parámetros ambientales en su central eléctrica partir de los monitoreos ambientales del 2018 -2021. La investigación es no experimental, analítico, predictivo, horizontal y retrospectivo. Se sistematizó y analizó las variaciones de los datos de 15 monitoreos trimestrales ambientales (04 años), y en base a ello se hizo análisis de tendencias y predicción de los cambios en los parámetros ambientales a través de modelamiento matemático utilizando el Modelo Holt-Winters con suavizado exponencial. Los resultados muestran que el Ruido en la central eléctrica de Requena, tienen una tendencia decreciente y los niveles de ruido cumplen con la calidad ambiental del ruido, que no son superiores a los 80 dB. El análisis de predicción para el próximo año reporta una evolución del ruido descendente de un nivel máximo de 61.02 dB hasta un nivel mínimo de 58.12 dB. En el campo electromagnético reporta valores bajos según los estándares calidad ambiental para radiaciones no ionizantes, estos valores alcanzados son muy inferiores al nivel máximo permitido de 4166.67 Voltios que es nivel máximo de intensidades de las radiaciones no ionizantes. El análisis de predicción reporta una evolución creciente desde un nivel mínimo de 55.55 V/m a un nivel máximo de 71.07 V/m. Con respecto a la calidad del aire, la evolución del material particulado PM-10 reporta valores por debajo de los Estándares Nacionales de Calidad Ambiental para Aire, que no superan los 100 ug/m3. El análisis de predicción reporta una tendencia decreciente desde un nivel máximo de 43.91 ug/m3 a un nivel mínimo de 36.14 ug/m3.application/pdfspaUniversidad Nacional de la Amazonía PeruanaPEinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/ParámetrosRuidoCentrales eléctricasImpacto ambientalZonas ruraleshttps://purl.org/pe-repo/ocde/ford#2.07.01Sistematización y análisis de la evolución de los parámetros ambientales en la central de generación eléctrica de la ciudad de Requena del 2018 - 2021, región Loreto - 2022info:eu-repo/semantics/bachelorThesisreponame:UNAPIquitos-Institucionalinstname:Universidad Nacional De La Amazonía Peruanainstacron:UNAPIquitosSUNEDUIngeniería en Gestión AmbientalUniversidad Nacional de la Amazonía Peruana. Facultad de AgronomíaIngeniero(a) en Gestión Ambiental70117466https://orcid.org/0000-0002-1708-710105220057https://purl.org/pe-repo/renati/type#tesis521236https://purl.org/pe-repo/renati/level#tituloProfesionalYalta Vega, RonaldFlores Malaverry, Jorge AgustínMachuca Espinar, Giorly GeovanniORIGINALChristian_Tesis_Titulo_2022.pdfChristian_Tesis_Titulo_2022.pdfTexto completoapplication/pdf1628863https://repositorio.unapiquitos.edu.pe/bitstreams/4c10dade-ab2b-46ad-8ad6-30638f2efbb2/download11b7c35f3e53ccd9b88c93e1502ce56bMD51trueAnonymousREADTEXTChristian_Tesis_Titulo_2022.pdf.txtChristian_Tesis_Titulo_2022.pdf.txtExtracted texttext/plain91647https://repositorio.unapiquitos.edu.pe/bitstreams/ee17f250-d7f6-4768-b568-d75be26dd641/download49426e0b335e33b2cb85164bfa083816MD528falseAnonymousREADTHUMBNAILChristian_Tesis_Titulo_2022.pdf.jpgChristian_Tesis_Titulo_2022.pdf.jpgGenerated Thumbnailimage/jpeg4168https://repositorio.unapiquitos.edu.pe/bitstreams/b9460596-edeb-40ea-847b-9242d3367c9e/downloaddd347bd359f5f147d7f80512e6f2cacfMD529falseAnonymousREAD20.500.12737/8477oai:repositorio.unapiquitos.edu.pe:20.500.12737/84772025-09-27T16:44:58.509064Zhttps://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessopen.accesshttps://repositorio.unapiquitos.edu.peRepositorio Digital UNAPrepositorio.institucional@unapiquitos.edu.pe
score 13.918182
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).