DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM

Descripción del Articulo

IN RADIOTHERAPY CENTERS, WHERE THERE ARE MORE THAN TWO LINEAR ACCELERATORS (LINACS) OF THE SAME MANUFACTURER AND MODEL, IT IS IMPORTANT TO CONSIDER A DOSIMETRIC PAIRING. FOR THIS REASON, THE INITIATIVE TO COMPARE THE DOSIMETRIC FACTORS OF TWO MODELS OF LINACS SYNERGY (ELEKTA) WITH PHOTONS OF 6 MEV O...

Descripción completa

Detalles Bibliográficos
Autores: PACHECO, JONATHAN W., GUZMÁN, CARMEN S., MÁRQUEZ, JOSÉ F., MÉNDEZ, JUAN A., VILLAVERDE, JESENIA, ALVA, MIRKO S.
Formato: artículo
Fecha de Publicación:2024
Institución:Universidad Nacional del Callao
Repositorio:UNAC-Institucional
Lenguaje:español
OAI Identifier:oai:repositorio.unac.edu.pe:20.500.12952/9845
Enlace del recurso:https://hdl.handle.net/20.500.12952/9845
Nivel de acceso:acceso abierto
Materia:MONTE CARLO METHOD, PARTICLE ACCELERATORS (SOURCE: DECS BIREME), RADIATION DOSE
https://purl.org/pe-repo/ocde/ford#2.00.00
id UNAC_a002848aa4be896162cd03fa979cb5ad
oai_identifier_str oai:repositorio.unac.edu.pe:20.500.12952/9845
network_acronym_str UNAC
network_name_str UNAC-Institucional
repository_id_str 2593
spelling PACHECO, JONATHAN W.GUZMÁN, CARMEN S.MÁRQUEZ, JOSÉ F.MÉNDEZ, JUAN A.VILLAVERDE, JESENIAALVA, MIRKO S.2025-02-28T20:26:59Z2025-02-28T20:26:59Z20241214470https://hdl.handle.net/20.500.12952/984510.15446/mo.n69.110775IN RADIOTHERAPY CENTERS, WHERE THERE ARE MORE THAN TWO LINEAR ACCELERATORS (LINACS) OF THE SAME MANUFACTURER AND MODEL, IT IS IMPORTANT TO CONSIDER A DOSIMETRIC PAIRING. FOR THIS REASON, THE INITIATIVE TO COMPARE THE DOSIMETRIC FACTORS OF TWO MODELS OF LINACS SYNERGY (ELEKTA) WITH PHOTONS OF 6 MEV OF ENERGY WAS PRESENTED. TOTAL DISPERSION FACTORS, DOSE VARIATION IN THE CENTRAL AXIS, DOSE PROFILE, WEDGE TRANSMISSION FACTORS, AND DOSE RATE WERE CONSIDERED. ABSOLUTE AND RELATIVE MEASUREMENTS WERE MADE WITH 5 IONIZATION CHAMBERS, FLAT DOSE DISTRIBUTIONS WERE OBTAINED WITH AN ARRANGEMENT OF 729 IONIZATION CHAMBERS, AND THE Γ INDEX WAS EVALUATED BY MEPHYSTO SOFTWARE. THE RESULTS OBTAINED WERE DOSE DIFFERENCE VALUES OF LESS THAN 1 %, REPRODUCED DOSE DISTRIBUTIONS WITH A VALUE GREATER THAN 95 % OF THE VOXELS ANALYZED FOR DISTANCE TO AGREEMENT (DTA) OF 2 MM AND ∆ DOSE OF 2 %, BOTH FOR PDD AND FOR EVALUATED PROFILES. THESE RESULTS WERE VALIDATED WITH DATA OBTAINED WITH MONTE CARLO SIMULATION (XVMC). IT WAS CONCLUDED THAT WITH THE METHODOLOGY DEVELOPED IT WAS POSSIBLE TO OBTAIN AN ADEQUATE PAIRING OF BEAMS GENERATED BY TWO DIFFERENT LINACS. © 2024, UNIVERSIDAD NACIONAL DE COLOMBIA. ALL RIGHTS RESERVED.application/pdfspaMOMENTOinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/MONTE CARLO METHOD, PARTICLE ACCELERATORS (SOURCE: DECS BIREME), RADIATION DOSEhttps://purl.org/pe-repo/ocde/ford#2.00.00DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEMinfo:eu-repo/semantics/articlereponame:UNAC-Institucionalinstname:Universidad Nacional del Callaoinstacron:UNAC20.500.12952/9845oai:repositorio.unac.edu.pe:20.500.12952/98452025-02-28 15:26:59.673https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessmetadata.onlyhttps://repositorio.unac.edu.peRepositorio de la Universidad Nacional del Callaodspace-help@myu.edu
dc.title.es_PE.fl_str_mv DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
title DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
spellingShingle DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
PACHECO, JONATHAN W.
MONTE CARLO METHOD, PARTICLE ACCELERATORS (SOURCE: DECS BIREME), RADIATION DOSE
https://purl.org/pe-repo/ocde/ford#2.00.00
title_short DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
title_full DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
title_fullStr DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
title_full_unstemmed DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
title_sort DOSIMETRIC PAIRING OF PHOTON BEAMS OF 6 MEV OF ENERGY FROM TWO LINEAR ACCELERATORS OF THE SAME COLLIMATION SYSTEM
author PACHECO, JONATHAN W.
author_facet PACHECO, JONATHAN W.
GUZMÁN, CARMEN S.
MÁRQUEZ, JOSÉ F.
MÉNDEZ, JUAN A.
VILLAVERDE, JESENIA
ALVA, MIRKO S.
author_role author
author2 GUZMÁN, CARMEN S.
MÁRQUEZ, JOSÉ F.
MÉNDEZ, JUAN A.
VILLAVERDE, JESENIA
ALVA, MIRKO S.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv PACHECO, JONATHAN W.
GUZMÁN, CARMEN S.
MÁRQUEZ, JOSÉ F.
MÉNDEZ, JUAN A.
VILLAVERDE, JESENIA
ALVA, MIRKO S.
dc.subject.es_PE.fl_str_mv MONTE CARLO METHOD, PARTICLE ACCELERATORS (SOURCE: DECS BIREME), RADIATION DOSE
topic MONTE CARLO METHOD, PARTICLE ACCELERATORS (SOURCE: DECS BIREME), RADIATION DOSE
https://purl.org/pe-repo/ocde/ford#2.00.00
dc.subject.ocde.es_PE.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.00.00
description IN RADIOTHERAPY CENTERS, WHERE THERE ARE MORE THAN TWO LINEAR ACCELERATORS (LINACS) OF THE SAME MANUFACTURER AND MODEL, IT IS IMPORTANT TO CONSIDER A DOSIMETRIC PAIRING. FOR THIS REASON, THE INITIATIVE TO COMPARE THE DOSIMETRIC FACTORS OF TWO MODELS OF LINACS SYNERGY (ELEKTA) WITH PHOTONS OF 6 MEV OF ENERGY WAS PRESENTED. TOTAL DISPERSION FACTORS, DOSE VARIATION IN THE CENTRAL AXIS, DOSE PROFILE, WEDGE TRANSMISSION FACTORS, AND DOSE RATE WERE CONSIDERED. ABSOLUTE AND RELATIVE MEASUREMENTS WERE MADE WITH 5 IONIZATION CHAMBERS, FLAT DOSE DISTRIBUTIONS WERE OBTAINED WITH AN ARRANGEMENT OF 729 IONIZATION CHAMBERS, AND THE Γ INDEX WAS EVALUATED BY MEPHYSTO SOFTWARE. THE RESULTS OBTAINED WERE DOSE DIFFERENCE VALUES OF LESS THAN 1 %, REPRODUCED DOSE DISTRIBUTIONS WITH A VALUE GREATER THAN 95 % OF THE VOXELS ANALYZED FOR DISTANCE TO AGREEMENT (DTA) OF 2 MM AND ∆ DOSE OF 2 %, BOTH FOR PDD AND FOR EVALUATED PROFILES. THESE RESULTS WERE VALIDATED WITH DATA OBTAINED WITH MONTE CARLO SIMULATION (XVMC). IT WAS CONCLUDED THAT WITH THE METHODOLOGY DEVELOPED IT WAS POSSIBLE TO OBTAIN AN ADEQUATE PAIRING OF BEAMS GENERATED BY TWO DIFFERENT LINACS. © 2024, UNIVERSIDAD NACIONAL DE COLOMBIA. ALL RIGHTS RESERVED.
publishDate 2024
dc.date.accessioned.none.fl_str_mv 2025-02-28T20:26:59Z
dc.date.available.none.fl_str_mv 2025-02-28T20:26:59Z
dc.date.issued.fl_str_mv 2024
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.issn.none.fl_str_mv 1214470
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12952/9845
dc.identifier.doi.none.fl_str_mv 10.15446/mo.n69.110775
identifier_str_mv 1214470
10.15446/mo.n69.110775
url https://hdl.handle.net/20.500.12952/9845
dc.language.iso.none.fl_str_mv spa
language spa
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MOMENTO
publisher.none.fl_str_mv MOMENTO
dc.source.none.fl_str_mv reponame:UNAC-Institucional
instname:Universidad Nacional del Callao
instacron:UNAC
instname_str Universidad Nacional del Callao
instacron_str UNAC
institution UNAC
reponame_str UNAC-Institucional
collection UNAC-Institucional
repository.name.fl_str_mv Repositorio de la Universidad Nacional del Callao
repository.mail.fl_str_mv dspace-help@myu.edu
_version_ 1846066473250848768
score 13.0450115
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).