Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
Descripción del Articulo
Climate change significantly impacts the lifestyle of people living in high Andean areas. For children, heat, combined with other environmental factors like humidity, leads to exhaustion — something experienced daily. Prolonged exposure to heat can cause side effects such as anxiety, and depression,...
| Autores: | , , |
|---|---|
| Formato: | tesis de grado |
| Fecha de Publicación: | 2025 |
| Institución: | Universidad Continental |
| Repositorio: | CONTINENTAL-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.continental.edu.pe:20.500.12394/17636 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12394/17636 https://doi.org/10.13189/cea.2025.130218 |
| Nivel de acceso: | acceso abierto |
| Materia: | Cambio climático Climate change Temperatura Temperature Termorregulación Thermoregulation Sostenibilidad Sustainability https://purl.org/pe-repo/ocde/ford#2.01.01 |
| id |
UCON_70e7857817dbfe9040a292d18507f9fc |
|---|---|
| oai_identifier_str |
oai:repositorio.continental.edu.pe:20.500.12394/17636 |
| network_acronym_str |
UCON |
| network_name_str |
CONTINENTAL-Institucional |
| repository_id_str |
4517 |
| dc.title.es_PE.fl_str_mv |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings |
| dc.title.alternative.es_PE.fl_str_mv |
Diseño de fachada piel para el equilibrio térmico en los edificios del Valle del Mantaro |
| title |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings |
| spellingShingle |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings Arias Coz, Oriana Ximena Cambio climático Climate change Temperatura Temperature Termorregulación Thermoregulation Sostenibilidad Sustainability https://purl.org/pe-repo/ocde/ford#2.01.01 |
| title_short |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings |
| title_full |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings |
| title_fullStr |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings |
| title_full_unstemmed |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings |
| title_sort |
Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings |
| author |
Arias Coz, Oriana Ximena |
| author_facet |
Arias Coz, Oriana Ximena Olivera Buendia, Marycielo Cyntia Montoya Torres, Vladimir Simón |
| author_role |
author |
| author2 |
Olivera Buendia, Marycielo Cyntia Montoya Torres, Vladimir Simón |
| author2_role |
author author |
| dc.contributor.advisor.fl_str_mv |
Montoya Torres, Vladimir Simon |
| dc.contributor.author.fl_str_mv |
Arias Coz, Oriana Ximena Olivera Buendia, Marycielo Cyntia Montoya Torres, Vladimir Simón |
| dc.subject.es_PE.fl_str_mv |
Cambio climático Climate change Temperatura Temperature Termorregulación Thermoregulation Sostenibilidad Sustainability |
| topic |
Cambio climático Climate change Temperatura Temperature Termorregulación Thermoregulation Sostenibilidad Sustainability https://purl.org/pe-repo/ocde/ford#2.01.01 |
| dc.subject.ocde.es_PE.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.01.01 |
| description |
Climate change significantly impacts the lifestyle of people living in high Andean areas. For children, heat, combined with other environmental factors like humidity, leads to exhaustion — something experienced daily. Prolonged exposure to heat can cause side effects such as anxiety, and depression, and contribute to mass migrations and regional conflicts, affecting local communities. Given these concerns, this research focuses on the thermal comfort of all types of buildings, whether residential or public. It proposes the importance of controlling internal temperatures, much like green walls or building placement systems that allow air to flow freely, creating cool chambers with stable temperatures for a greater sense of comfort. To achieve this, a system of modular architectural membranes was designed and prototyped. These membranes are tailored to the specific needs of the geographical region where the study was conducted, as each area requires dynamic, flexible geometries capable of forming responsive and intelligent morphologies. The results have effectively met the thermal control needs of buildings in the Mantaro Valley, complying with ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) standards for thermal comfort. Additionally, the system integrates high Andean cultural elements, preserving traditions and art to reinforce identity, as expressed through iconography in the "lliclla," a traditional Andean mantle. Finally, it’s important to mention that various tools were used throughout the data collection, implementation, and design modification processes. SketchUp and V - Ray were utilized for design and presentation; MS Excel, Meteonorm, and WeatherSpark for pre - prototype data collection; and GeoGebra and Climate Consultant for adjustments and changes due to external factors like sudden temperature shifts and the structure of the building where the prototype data was collected. |
| publishDate |
2025 |
| dc.date.accessioned.none.fl_str_mv |
2025-07-03T21:04:26Z |
| dc.date.available.none.fl_str_mv |
2025-07-03T21:04:26Z |
| dc.date.issued.fl_str_mv |
2025 |
| dc.type.es_PE.fl_str_mv |
info:eu-repo/semantics/bachelorThesis |
| dc.type.version.es_PE.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| format |
bachelorThesis |
| status_str |
publishedVersion |
| dc.identifier.citation.es_PE.fl_str_mv |
Olivera, M., Arias, O., & Montoya, V. (2025). Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://repositorio.continental.edu.pe/handle/20.500.12394/17636 |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12394/17636 |
| dc.identifier.journal.es_PE.fl_str_mv |
Civil Engineering and Architecture |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.13189/cea.2025.130218 |
| identifier_str_mv |
Olivera, M., Arias, O., & Montoya, V. (2025). Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://repositorio.continental.edu.pe/handle/20.500.12394/17636 Civil Engineering and Architecture |
| url |
https://hdl.handle.net/20.500.12394/17636 https://doi.org/10.13189/cea.2025.130218 |
| dc.language.iso.es_PE.fl_str_mv |
eng |
| language |
eng |
| dc.relation.es_PE.fl_str_mv |
https://www.hrpub.org/journals/article_info.php?aid=14785 |
| dc.relation.ispartof.fl_str_mv |
SUNEDU |
| dc.rights.es_PE.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.es_PE.fl_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
| dc.rights.license.es_PE.fl_str_mv |
Attribution 4.0 International (CC BY 4.0) |
| dc.rights.accessRights.es_PE.fl_str_mv |
Acceso abierto |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ Attribution 4.0 International (CC BY 4.0) Acceso abierto |
| dc.format.es_PE.fl_str_mv |
application/pdf |
| dc.format.extent.es_PE.fl_str_mv |
p. 1002-1013 |
| dc.publisher.es_PE.fl_str_mv |
Universidad Continental |
| dc.publisher.country.es_PE.fl_str_mv |
PE |
| dc.source.es_PE.fl_str_mv |
Universidad Continental Repositorio Institucional - Continental |
| dc.source.none.fl_str_mv |
reponame:CONTINENTAL-Institucional instname:Universidad Continental instacron:CONTINENTAL |
| instname_str |
Universidad Continental |
| instacron_str |
CONTINENTAL |
| institution |
CONTINENTAL |
| reponame_str |
CONTINENTAL-Institucional |
| collection |
CONTINENTAL-Institucional |
| bitstream.url.fl_str_mv |
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/5/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txt https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/7/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.txt https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/9/Informe_Turnitin.pdf.txt https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/6/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpg https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/8/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.jpg https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/10/Informe_Turnitin.pdf.jpg https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/2/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/3/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/4/Informe_Turnitin.pdf https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/1/license.txt |
| bitstream.checksum.fl_str_mv |
65c24e1490d1b0f983796f7351b44fd9 eeca432ad1ebb1a06d9f2a74136857f0 1a8118788148b3ad05786877937ab122 dfabbf65a7ecf7c206f5cf24250fa9fa d6a997a28de40cd2bf4405766e64f979 5283edaec8d431614246d923143304ba d1b5d3b4d011fbd63902923a5618df29 bdfd9676979e6ff77dbb73cabf079896 4bf6f598eac0518130cce404b1c41b28 8a4605be74aa9ea9d79846c1fba20a33 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Continental |
| repository.mail.fl_str_mv |
dspaceconti@continental.edu.pe |
| _version_ |
1847603505717575680 |
| spelling |
Montoya Torres, Vladimir SimonArias Coz, Oriana XimenaOlivera Buendia, Marycielo CyntiaMontoya Torres, Vladimir Simón2025-07-03T21:04:26Z2025-07-03T21:04:26Z2025Olivera, M., Arias, O., & Montoya, V. (2025). Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://repositorio.continental.edu.pe/handle/20.500.12394/17636https://hdl.handle.net/20.500.12394/17636Civil Engineering and Architecturehttps://doi.org/10.13189/cea.2025.130218Climate change significantly impacts the lifestyle of people living in high Andean areas. For children, heat, combined with other environmental factors like humidity, leads to exhaustion — something experienced daily. Prolonged exposure to heat can cause side effects such as anxiety, and depression, and contribute to mass migrations and regional conflicts, affecting local communities. Given these concerns, this research focuses on the thermal comfort of all types of buildings, whether residential or public. It proposes the importance of controlling internal temperatures, much like green walls or building placement systems that allow air to flow freely, creating cool chambers with stable temperatures for a greater sense of comfort. To achieve this, a system of modular architectural membranes was designed and prototyped. These membranes are tailored to the specific needs of the geographical region where the study was conducted, as each area requires dynamic, flexible geometries capable of forming responsive and intelligent morphologies. The results have effectively met the thermal control needs of buildings in the Mantaro Valley, complying with ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) standards for thermal comfort. Additionally, the system integrates high Andean cultural elements, preserving traditions and art to reinforce identity, as expressed through iconography in the "lliclla," a traditional Andean mantle. Finally, it’s important to mention that various tools were used throughout the data collection, implementation, and design modification processes. SketchUp and V - Ray were utilized for design and presentation; MS Excel, Meteonorm, and WeatherSpark for pre - prototype data collection; and GeoGebra and Climate Consultant for adjustments and changes due to external factors like sudden temperature shifts and the structure of the building where the prototype data was collected.application/pdfp. 1002-1013engUniversidad ContinentalPEhttps://www.hrpub.org/journals/article_info.php?aid=14785SUNEDUinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/Attribution 4.0 International (CC BY 4.0)Acceso abiertoUniversidad ContinentalRepositorio Institucional - Continentalreponame:CONTINENTAL-Institucionalinstname:Universidad Continentalinstacron:CONTINENTALCambio climáticoClimate changeTemperaturaTemperatureTermorregulaciónThermoregulationSostenibilidadSustainabilityhttps://purl.org/pe-repo/ocde/ford#2.01.01Skin Facade Design for the Thermal Balance in the Mantaro Valley BuildingsDiseño de fachada piel para el equilibrio térmico en los edificios del Valle del Mantaroinfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/publishedVersionArquitectoUniversidad Continental. Facultad de Ingeniería.ArquitecturaPregrado presencial regular42220391https://orcid.org/0000-0002-5205-6255774691737403320742220391731026https://purl.org/pe-repo/renati/level#tituloProfesionalhttps://purl.org/pe-repo/renati/type#tesisTEXTIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txtIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txtExtracted texttext/plain39895https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/5/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txt65c24e1490d1b0f983796f7351b44fd9MD55IV_FIN_106_Autorización_2025.pdf.txtIV_FIN_106_Autorización_2025.pdf.txtExtracted texttext/plain3551https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/7/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.txteeca432ad1ebb1a06d9f2a74136857f0MD57Informe_Turnitin.pdf.txtInforme_Turnitin.pdf.txtExtracted texttext/plain1698https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/9/Informe_Turnitin.pdf.txt1a8118788148b3ad05786877937ab122MD59THUMBNAILIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpgIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpgGenerated Thumbnailimage/jpeg2545https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/6/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpgdfabbf65a7ecf7c206f5cf24250fa9faMD56IV_FIN_106_Autorización_2025.pdf.jpgIV_FIN_106_Autorización_2025.pdf.jpgGenerated Thumbnailimage/jpeg3990https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/8/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.jpgd6a997a28de40cd2bf4405766e64f979MD58Informe_Turnitin.pdf.jpgInforme_Turnitin.pdf.jpgGenerated Thumbnailimage/jpeg1960https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/10/Informe_Turnitin.pdf.jpg5283edaec8d431614246d923143304baMD510ORIGINALIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdfIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdfArias Coz, Oriana Ximena; Olivera Buendia, Marycielo Cyntia; Montoya Torres, Vladimir Simónapplication/pdf3988419https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/2/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdfd1b5d3b4d011fbd63902923a5618df29MD52IV_FIN_106_Autorización_2025.pdfIV_FIN_106_Autorización_2025.pdfAutorizaciónapplication/pdf305630https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/3/IV_FIN_106_Autorizaci%c3%b3n_2025.pdfbdfd9676979e6ff77dbb73cabf079896MD53Informe_Turnitin.pdfInforme_Turnitin.pdfInforme de Turnitinapplication/pdf4850955https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/4/Informe_Turnitin.pdf4bf6f598eac0518130cce404b1c41b28MD54LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/1/license.txt8a4605be74aa9ea9d79846c1fba20a33MD5120.500.12394/17636oai:repositorio.continental.edu.pe:20.500.12394/176362025-08-28 17:39:50.166Repositorio Continentaldspaceconti@continental.edu.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 |
| score |
12.8697195 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).