Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings

Descripción del Articulo

Climate change significantly impacts the lifestyle of people living in high Andean areas. For children, heat, combined with other environmental factors like humidity, leads to exhaustion — something experienced daily. Prolonged exposure to heat can cause side effects such as anxiety, and depression,...

Descripción completa

Detalles Bibliográficos
Autores: Arias Coz, Oriana Ximena, Olivera Buendia, Marycielo Cyntia, Montoya Torres, Vladimir Simón
Formato: tesis de grado
Fecha de Publicación:2025
Institución:Universidad Continental
Repositorio:CONTINENTAL-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.continental.edu.pe:20.500.12394/17636
Enlace del recurso:https://hdl.handle.net/20.500.12394/17636
https://doi.org/10.13189/cea.2025.130218
Nivel de acceso:acceso abierto
Materia:Cambio climático
Climate change
Temperatura
Temperature
Termorregulación
Thermoregulation
Sostenibilidad
Sustainability
https://purl.org/pe-repo/ocde/ford#2.01.01
id UCON_70e7857817dbfe9040a292d18507f9fc
oai_identifier_str oai:repositorio.continental.edu.pe:20.500.12394/17636
network_acronym_str UCON
network_name_str CONTINENTAL-Institucional
repository_id_str 4517
dc.title.es_PE.fl_str_mv Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
dc.title.alternative.es_PE.fl_str_mv Diseño de fachada piel para el equilibrio térmico en los edificios del Valle del Mantaro
title Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
spellingShingle Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
Arias Coz, Oriana Ximena
Cambio climático
Climate change
Temperatura
Temperature
Termorregulación
Thermoregulation
Sostenibilidad
Sustainability
https://purl.org/pe-repo/ocde/ford#2.01.01
title_short Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
title_full Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
title_fullStr Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
title_full_unstemmed Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
title_sort Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings
author Arias Coz, Oriana Ximena
author_facet Arias Coz, Oriana Ximena
Olivera Buendia, Marycielo Cyntia
Montoya Torres, Vladimir Simón
author_role author
author2 Olivera Buendia, Marycielo Cyntia
Montoya Torres, Vladimir Simón
author2_role author
author
dc.contributor.advisor.fl_str_mv Montoya Torres, Vladimir Simon
dc.contributor.author.fl_str_mv Arias Coz, Oriana Ximena
Olivera Buendia, Marycielo Cyntia
Montoya Torres, Vladimir Simón
dc.subject.es_PE.fl_str_mv Cambio climático
Climate change
Temperatura
Temperature
Termorregulación
Thermoregulation
Sostenibilidad
Sustainability
topic Cambio climático
Climate change
Temperatura
Temperature
Termorregulación
Thermoregulation
Sostenibilidad
Sustainability
https://purl.org/pe-repo/ocde/ford#2.01.01
dc.subject.ocde.es_PE.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.01.01
description Climate change significantly impacts the lifestyle of people living in high Andean areas. For children, heat, combined with other environmental factors like humidity, leads to exhaustion — something experienced daily. Prolonged exposure to heat can cause side effects such as anxiety, and depression, and contribute to mass migrations and regional conflicts, affecting local communities. Given these concerns, this research focuses on the thermal comfort of all types of buildings, whether residential or public. It proposes the importance of controlling internal temperatures, much like green walls or building placement systems that allow air to flow freely, creating cool chambers with stable temperatures for a greater sense of comfort. To achieve this, a system of modular architectural membranes was designed and prototyped. These membranes are tailored to the specific needs of the geographical region where the study was conducted, as each area requires dynamic, flexible geometries capable of forming responsive and intelligent morphologies. The results have effectively met the thermal control needs of buildings in the Mantaro Valley, complying with ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) standards for thermal comfort. Additionally, the system integrates high Andean cultural elements, preserving traditions and art to reinforce identity, as expressed through iconography in the "lliclla," a traditional Andean mantle. Finally, it’s important to mention that various tools were used throughout the data collection, implementation, and design modification processes. SketchUp and V - Ray were utilized for design and presentation; MS Excel, Meteonorm, and WeatherSpark for pre - prototype data collection; and GeoGebra and Climate Consultant for adjustments and changes due to external factors like sudden temperature shifts and the structure of the building where the prototype data was collected.
publishDate 2025
dc.date.accessioned.none.fl_str_mv 2025-07-03T21:04:26Z
dc.date.available.none.fl_str_mv 2025-07-03T21:04:26Z
dc.date.issued.fl_str_mv 2025
dc.type.es_PE.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.version.es_PE.fl_str_mv info:eu-repo/semantics/publishedVersion
format bachelorThesis
status_str publishedVersion
dc.identifier.citation.es_PE.fl_str_mv Olivera, M., Arias, O., & Montoya, V. (2025). Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://repositorio.continental.edu.pe/handle/20.500.12394/17636
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12394/17636
dc.identifier.journal.es_PE.fl_str_mv Civil Engineering and Architecture
dc.identifier.doi.none.fl_str_mv https://doi.org/10.13189/cea.2025.130218
identifier_str_mv Olivera, M., Arias, O., & Montoya, V. (2025). Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://repositorio.continental.edu.pe/handle/20.500.12394/17636
Civil Engineering and Architecture
url https://hdl.handle.net/20.500.12394/17636
https://doi.org/10.13189/cea.2025.130218
dc.language.iso.es_PE.fl_str_mv eng
language eng
dc.relation.es_PE.fl_str_mv https://www.hrpub.org/journals/article_info.php?aid=14785
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.es_PE.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.es_PE.fl_str_mv https://creativecommons.org/licenses/by/4.0/
dc.rights.license.es_PE.fl_str_mv Attribution 4.0 International (CC BY 4.0)
dc.rights.accessRights.es_PE.fl_str_mv Acceso abierto
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
Attribution 4.0 International (CC BY 4.0)
Acceso abierto
dc.format.es_PE.fl_str_mv application/pdf
dc.format.extent.es_PE.fl_str_mv p. 1002-1013
dc.publisher.es_PE.fl_str_mv Universidad Continental
dc.publisher.country.es_PE.fl_str_mv PE
dc.source.es_PE.fl_str_mv Universidad Continental
Repositorio Institucional - Continental
dc.source.none.fl_str_mv reponame:CONTINENTAL-Institucional
instname:Universidad Continental
instacron:CONTINENTAL
instname_str Universidad Continental
instacron_str CONTINENTAL
institution CONTINENTAL
reponame_str CONTINENTAL-Institucional
collection CONTINENTAL-Institucional
bitstream.url.fl_str_mv https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/5/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txt
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/7/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.txt
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/9/Informe_Turnitin.pdf.txt
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/6/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpg
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/8/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.jpg
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/10/Informe_Turnitin.pdf.jpg
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/2/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/3/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/4/Informe_Turnitin.pdf
https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/1/license.txt
bitstream.checksum.fl_str_mv 65c24e1490d1b0f983796f7351b44fd9
eeca432ad1ebb1a06d9f2a74136857f0
1a8118788148b3ad05786877937ab122
dfabbf65a7ecf7c206f5cf24250fa9fa
d6a997a28de40cd2bf4405766e64f979
5283edaec8d431614246d923143304ba
d1b5d3b4d011fbd63902923a5618df29
bdfd9676979e6ff77dbb73cabf079896
4bf6f598eac0518130cce404b1c41b28
8a4605be74aa9ea9d79846c1fba20a33
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Continental
repository.mail.fl_str_mv dspaceconti@continental.edu.pe
_version_ 1847603505717575680
spelling Montoya Torres, Vladimir SimonArias Coz, Oriana XimenaOlivera Buendia, Marycielo CyntiaMontoya Torres, Vladimir Simón2025-07-03T21:04:26Z2025-07-03T21:04:26Z2025Olivera, M., Arias, O., & Montoya, V. (2025). Skin Facade Design for the Thermal Balance in the Mantaro Valley Buildings [Tesis de licenciatura, Universidad Continental]. Repositorio Institucional Continental. https://repositorio.continental.edu.pe/handle/20.500.12394/17636https://hdl.handle.net/20.500.12394/17636Civil Engineering and Architecturehttps://doi.org/10.13189/cea.2025.130218Climate change significantly impacts the lifestyle of people living in high Andean areas. For children, heat, combined with other environmental factors like humidity, leads to exhaustion — something experienced daily. Prolonged exposure to heat can cause side effects such as anxiety, and depression, and contribute to mass migrations and regional conflicts, affecting local communities. Given these concerns, this research focuses on the thermal comfort of all types of buildings, whether residential or public. It proposes the importance of controlling internal temperatures, much like green walls or building placement systems that allow air to flow freely, creating cool chambers with stable temperatures for a greater sense of comfort. To achieve this, a system of modular architectural membranes was designed and prototyped. These membranes are tailored to the specific needs of the geographical region where the study was conducted, as each area requires dynamic, flexible geometries capable of forming responsive and intelligent morphologies. The results have effectively met the thermal control needs of buildings in the Mantaro Valley, complying with ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers) standards for thermal comfort. Additionally, the system integrates high Andean cultural elements, preserving traditions and art to reinforce identity, as expressed through iconography in the "lliclla," a traditional Andean mantle. Finally, it’s important to mention that various tools were used throughout the data collection, implementation, and design modification processes. SketchUp and V - Ray were utilized for design and presentation; MS Excel, Meteonorm, and WeatherSpark for pre - prototype data collection; and GeoGebra and Climate Consultant for adjustments and changes due to external factors like sudden temperature shifts and the structure of the building where the prototype data was collected.application/pdfp. 1002-1013engUniversidad ContinentalPEhttps://www.hrpub.org/journals/article_info.php?aid=14785SUNEDUinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by/4.0/Attribution 4.0 International (CC BY 4.0)Acceso abiertoUniversidad ContinentalRepositorio Institucional - Continentalreponame:CONTINENTAL-Institucionalinstname:Universidad Continentalinstacron:CONTINENTALCambio climáticoClimate changeTemperaturaTemperatureTermorregulaciónThermoregulationSostenibilidadSustainabilityhttps://purl.org/pe-repo/ocde/ford#2.01.01Skin Facade Design for the Thermal Balance in the Mantaro Valley BuildingsDiseño de fachada piel para el equilibrio térmico en los edificios del Valle del Mantaroinfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/publishedVersionArquitectoUniversidad Continental. Facultad de Ingeniería.ArquitecturaPregrado presencial regular42220391https://orcid.org/0000-0002-5205-6255774691737403320742220391731026https://purl.org/pe-repo/renati/level#tituloProfesionalhttps://purl.org/pe-repo/renati/type#tesisTEXTIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txtIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txtExtracted texttext/plain39895https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/5/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.txt65c24e1490d1b0f983796f7351b44fd9MD55IV_FIN_106_Autorización_2025.pdf.txtIV_FIN_106_Autorización_2025.pdf.txtExtracted texttext/plain3551https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/7/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.txteeca432ad1ebb1a06d9f2a74136857f0MD57Informe_Turnitin.pdf.txtInforme_Turnitin.pdf.txtExtracted texttext/plain1698https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/9/Informe_Turnitin.pdf.txt1a8118788148b3ad05786877937ab122MD59THUMBNAILIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpgIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpgGenerated Thumbnailimage/jpeg2545https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/6/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdf.jpgdfabbf65a7ecf7c206f5cf24250fa9faMD56IV_FIN_106_Autorización_2025.pdf.jpgIV_FIN_106_Autorización_2025.pdf.jpgGenerated Thumbnailimage/jpeg3990https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/8/IV_FIN_106_Autorizaci%c3%b3n_2025.pdf.jpgd6a997a28de40cd2bf4405766e64f979MD58Informe_Turnitin.pdf.jpgInforme_Turnitin.pdf.jpgGenerated Thumbnailimage/jpeg1960https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/10/Informe_Turnitin.pdf.jpg5283edaec8d431614246d923143304baMD510ORIGINALIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdfIV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdfArias Coz, Oriana Ximena; Olivera Buendia, Marycielo Cyntia; Montoya Torres, Vladimir Simónapplication/pdf3988419https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/2/IV_FIN_106_TE_Arias_Olivera_Montoya_2025.pdfd1b5d3b4d011fbd63902923a5618df29MD52IV_FIN_106_Autorización_2025.pdfIV_FIN_106_Autorización_2025.pdfAutorizaciónapplication/pdf305630https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/3/IV_FIN_106_Autorizaci%c3%b3n_2025.pdfbdfd9676979e6ff77dbb73cabf079896MD53Informe_Turnitin.pdfInforme_Turnitin.pdfInforme de Turnitinapplication/pdf4850955https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/4/Informe_Turnitin.pdf4bf6f598eac0518130cce404b1c41b28MD54LICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.continental.edu.pe/bitstream/20.500.12394/17636/1/license.txt8a4605be74aa9ea9d79846c1fba20a33MD5120.500.12394/17636oai:repositorio.continental.edu.pe:20.500.12394/176362025-08-28 17:39:50.166Repositorio Continentaldspaceconti@continental.edu.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
score 12.8697195
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).