Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare

Descripción del Articulo

A clinical Flow Cytometry laboratory underwent a diagnosis of its TAT indicator over a period of one year, finding an excess of 3,83 hours or 15,94% with respect to the 24-hour sector range. The response time (TAT) in a clinical laboratory is an indicator that measures the efficiency and quality of...

Descripción completa

Detalles Bibliográficos
Autores: Diaz Amaro, Marcos Antonio, Salazar Carrillo, Almendra Alexia
Formato: tesis de grado
Fecha de Publicación:2025
Institución:Universidad de Lima
Repositorio:ULIMA-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.ulima.edu.pe:20.500.12724/23452
Enlace del recurso:https://hdl.handle.net/20.500.12724/23452
Nivel de acceso:acceso abierto
Materia:Laboratorios de patología
Automatización de laboratorios
Efectividad organizacional
Evaluación de procesos (Atención de médica)
Producción eficiente
Proceso de mejora continua
https://purl.org/pe-repo/ocde/ford#2.11.04
id RULI_7ab45d76534bf82db5065cbe90225913
oai_identifier_str oai:repositorio.ulima.edu.pe:20.500.12724/23452
network_acronym_str RULI
network_name_str ULIMA-Institucional
repository_id_str 3883
dc.title.en_EN.fl_str_mv Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
title Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
spellingShingle Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
Diaz Amaro, Marcos Antonio
Laboratorios de patología
Automatización de laboratorios
Efectividad organizacional
Evaluación de procesos (Atención de médica)
Producción eficiente
Proceso de mejora continua
https://purl.org/pe-repo/ocde/ford#2.11.04
title_short Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
title_full Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
title_fullStr Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
title_full_unstemmed Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
title_sort Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcare
author Diaz Amaro, Marcos Antonio
author_facet Diaz Amaro, Marcos Antonio
Salazar Carrillo, Almendra Alexia
author_role author
author2 Salazar Carrillo, Almendra Alexia
author2_role author
dc.contributor.advisor.fl_str_mv Quiroz Flores, Juan Carlos
dc.contributor.author.fl_str_mv Diaz Amaro, Marcos Antonio
Salazar Carrillo, Almendra Alexia
dc.subject.es_PE.fl_str_mv Laboratorios de patología
Automatización de laboratorios
Efectividad organizacional
Evaluación de procesos (Atención de médica)
Producción eficiente
Proceso de mejora continua
topic Laboratorios de patología
Automatización de laboratorios
Efectividad organizacional
Evaluación de procesos (Atención de médica)
Producción eficiente
Proceso de mejora continua
https://purl.org/pe-repo/ocde/ford#2.11.04
dc.subject.ocde.none.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.11.04
description A clinical Flow Cytometry laboratory underwent a diagnosis of its TAT indicator over a period of one year, finding an excess of 3,83 hours or 15,94% with respect to the 24-hour sector range. The response time (TAT) in a clinical laboratory is an indicator that measures the efficiency and quality of the service offered by delivering results reports on time. A TAT within the established parameters makes it possible to offer rapid treatment to patients, respond to the demand of an aging population and combat limited resources. As a proposal to improve the situation, pilot tests were implemented in the laboratory by applying lean Healthcare tools (KANBAN, SMED) and the automation method to its operational processes. Through a statistical validation of the results obtained through Student's t-test, a reduction of 12,86% of the TAT and the elimination of non-compliant products generated in the laboratory marking area is affirmed. Likewise, the project will be considered economically viable with an IRR of 67% and a B/C of 2.27. Finally, the project also contributes to the sustainable development goals towards 2030 number 3, 8 and 10.
publishDate 2025
dc.date.accessioned.none.fl_str_mv 2025-10-10T15:14:20Z
dc.date.available.none.fl_str_mv 2025-10-10T15:14:20Z
dc.date.issued.fl_str_mv 2025
dc.type.none.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.other.none.fl_str_mv Tesis
format bachelorThesis
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12724/23452
dc.identifier.isni.none.fl_str_mv 0000000121541816
url https://hdl.handle.net/20.500.12724/23452
identifier_str_mv 0000000121541816
dc.language.iso.none.fl_str_mv eng
language eng
dc.relation.ispartof.fl_str_mv SUNEDU
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv https://creativecommons.org/licenses/by-nc-sa/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/4.0/
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad de Lima
dc.publisher.country.none.fl_str_mv PE
publisher.none.fl_str_mv Universidad de Lima
dc.source.none.fl_str_mv reponame:ULIMA-Institucional
instname:Universidad de Lima
instacron:ULIMA
instname_str Universidad de Lima
instacron_str ULIMA
institution ULIMA
reponame_str ULIMA-Institucional
collection ULIMA-Institucional
bitstream.url.fl_str_mv https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/1/T018_71222862_T.pdf
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/2/FA_71222862_SR.pdf
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/3/TURNITIN_DIAZ%20AMARO%20MARCOS%20ANTONIO_20190618%20.pdf
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/4/T018_71222862_T.pdf.txt
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/6/FA_71222862_SR.pdf.txt
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/8/TURNITIN_DIAZ%20AMARO%20MARCOS%20ANTONIO_20190618%20.pdf.txt
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/5/T018_71222862_T.pdf.jpg
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/7/FA_71222862_SR.pdf.jpg
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/9/TURNITIN_DIAZ%20AMARO%20MARCOS%20ANTONIO_20190618%20.pdf.jpg
bitstream.checksum.fl_str_mv c968230ce81d46e80170f3fa29db980c
4106736241a6e9635e995da7ee38c8b2
5831bc90cd5cb157f527e5277d090395
e93ef116929005ce7d609164f301ea9f
7e223d51547343485385fe03167804c1
ea71af8ae1371dd1b7bfb1ffc5c9afec
f4a37566c3cb354fc6da59dd7a586e21
80bae38a70941450a85116e07149d9cb
e225275318d2156726bb9bedb0236b3c
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
MD5
MD5
MD5
MD5
repository.name.fl_str_mv Repositorio Universidad de Lima
repository.mail.fl_str_mv repositorio@ulima.edu.pe
_version_ 1868173656343969792
spelling Quiroz Flores, Juan CarlosDiaz Amaro, Marcos AntonioSalazar Carrillo, Almendra Alexia2025-10-10T15:14:20Z2025-10-10T15:14:20Z2025https://hdl.handle.net/20.500.12724/234520000000121541816A clinical Flow Cytometry laboratory underwent a diagnosis of its TAT indicator over a period of one year, finding an excess of 3,83 hours or 15,94% with respect to the 24-hour sector range. The response time (TAT) in a clinical laboratory is an indicator that measures the efficiency and quality of the service offered by delivering results reports on time. A TAT within the established parameters makes it possible to offer rapid treatment to patients, respond to the demand of an aging population and combat limited resources. As a proposal to improve the situation, pilot tests were implemented in the laboratory by applying lean Healthcare tools (KANBAN, SMED) and the automation method to its operational processes. Through a statistical validation of the results obtained through Student's t-test, a reduction of 12,86% of the TAT and the elimination of non-compliant products generated in the laboratory marking area is affirmed. Likewise, the project will be considered economically viable with an IRR of 67% and a B/C of 2.27. Finally, the project also contributes to the sustainable development goals towards 2030 number 3, 8 and 10.En un laboratorio clínico de Citometría de Flujo se realizó un diagnóstico anual del indicador Tiempo de respuesta (TAT), hallando un excedente de 3,83 horas que es equivalente a un 15,94% de brecha técnica respecto al sector, cuyo valor se encuentra en 24 horas. El TAT en un laboratorio clínico es un indicador que mide la eficiencia y la calidad del servicio ofrecido mediante la entrega puntual de informes de resultados a los clientes. Un TAT dentro de los parámetros establecidos permite ofrecer un tratamiento rápido a los usuarios finales, responder a la demanda de una población envejecida y combatir la escasez de recursos. Como propuesta para mejorar la situación actual de la empresa, se implementaron pruebas piloto en el laboratorio mediante la aplicación de herramientas lean Healthcare (KANBAN, SMED) y el método de automatización a sus procesos operativos. Los cuales, a través de una validación estadística de los resultados obtenidos utilizando la prueba t de Student en Minitab, se confirmó una reducción del 12,86 % del TAT y la eliminación de productos no conformes. Asimismo, el proyecto se consideró económicamente viable con una TIR del 67 % y una relación B/C de 2,27. Finalmente, el proyecto también contribuye a los objetivos de desarrollo sostenible al 2030 número 3, 8 y 10.application/pdfengUniversidad de LimaPEinfo:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/4.0/Laboratorios de patologíaAutomatización de laboratoriosEfectividad organizacionalEvaluación de procesos (Atención de médica)Producción eficienteProceso de mejora continuahttps://purl.org/pe-repo/ocde/ford#2.11.04Reducing turnaround time in a clinical laboratory by using a management model utilizing process automation and lean healthcareinfo:eu-repo/semantics/bachelorThesisTesisreponame:ULIMA-Institucionalinstname:Universidad de Limainstacron:ULIMASUNEDUTítulo profesionalIngeniería IndustrialUniversidad de Lima. Facultad de IngenieríaIngeniero Industrialhttps://orcid.org/0000-0003-1858-4123103002857220267122286272623927https://purl.org/pe-repo/renati/level#tituloProfesionalUrbina Rivera, Carlos MedardoAlmandoz Núñez, Ana MaríaQuiroz Flores, Juan Carloshttps://purl.org/pe-repo/renati/type#tesis015ORIGINALT018_71222862_T.pdfT018_71222862_T.pdfDescargarapplication/pdf380356https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/1/T018_71222862_T.pdfc968230ce81d46e80170f3fa29db980cMD51FA_71222862_SR.pdfFA_71222862_SR.pdfAutorizaciónapplication/pdf248743https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/2/FA_71222862_SR.pdf4106736241a6e9635e995da7ee38c8b2MD52TURNITIN_DIAZ AMARO MARCOS ANTONIO_20190618 .pdfTURNITIN_DIAZ AMARO MARCOS ANTONIO_20190618 .pdfReporte de Similitudapplication/pdf528018https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/3/TURNITIN_DIAZ%20AMARO%20MARCOS%20ANTONIO_20190618%20.pdf5831bc90cd5cb157f527e5277d090395MD53TEXTT018_71222862_T.pdf.txtT018_71222862_T.pdf.txtExtracted texttext/plain21737https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/4/T018_71222862_T.pdf.txte93ef116929005ce7d609164f301ea9fMD54FA_71222862_SR.pdf.txtFA_71222862_SR.pdf.txtExtracted texttext/plain4358https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/6/FA_71222862_SR.pdf.txt7e223d51547343485385fe03167804c1MD56TURNITIN_DIAZ AMARO MARCOS ANTONIO_20190618 .pdf.txtTURNITIN_DIAZ AMARO MARCOS ANTONIO_20190618 .pdf.txtExtracted texttext/plain25368https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/8/TURNITIN_DIAZ%20AMARO%20MARCOS%20ANTONIO_20190618%20.pdf.txtea71af8ae1371dd1b7bfb1ffc5c9afecMD58THUMBNAILT018_71222862_T.pdf.jpgT018_71222862_T.pdf.jpgGenerated Thumbnailimage/jpeg12114https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/5/T018_71222862_T.pdf.jpgf4a37566c3cb354fc6da59dd7a586e21MD55FA_71222862_SR.pdf.jpgFA_71222862_SR.pdf.jpgGenerated Thumbnailimage/jpeg21250https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/7/FA_71222862_SR.pdf.jpg80bae38a70941450a85116e07149d9cbMD57TURNITIN_DIAZ AMARO MARCOS ANTONIO_20190618 .pdf.jpgTURNITIN_DIAZ AMARO MARCOS ANTONIO_20190618 .pdf.jpgGenerated Thumbnailimage/jpeg8124https://repositorio.ulima.edu.pe/bitstream/20.500.12724/23452/9/TURNITIN_DIAZ%20AMARO%20MARCOS%20ANTONIO_20190618%20.pdf.jpge225275318d2156726bb9bedb0236b3cMD5920.500.12724/23452oai:repositorio.ulima.edu.pe:20.500.12724/234522026-05-28 18:41:32.78Repositorio Universidad de Limarepositorio@ulima.edu.pe
score 13.075366
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).