Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design

Descripción del Articulo

This study intends to assess the removal efficiency of the chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total suspended solids (TSS) from raw tannery wastewater using electrocoagulation by aluminum electrodes as well as to determine the effects of its main operating factors. Th...

Descripción completa

Detalles Bibliográficos
Autores: Aguilar Ascón, Edwar, Marrufo Saldaña, Liliana, Neyra Ascón, Walter
Formato: artículo
Fecha de Publicación:2020
Institución:Universidad de Lima
Repositorio:ULIMA-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.ulima.edu.pe:20.500.12724/11847
Enlace del recurso:https://hdl.handle.net/20.500.12724/11847
https://doi.org/10.24264/lfj.20.3.1
Nivel de acceso:acceso abierto
Materia:Electrocoagulation
Water treatment
Sewage
Curtido
Tanning
Electrocoagulación
Tratamiento del agua
https://purl.org/pe-repo/ocde/ford#2.11.04
id RULI_5dcfdce582805efb8a9e8d9ad5f1e3ba
oai_identifier_str oai:repositorio.ulima.edu.pe:20.500.12724/11847
network_acronym_str RULI
network_name_str ULIMA-Institucional
repository_id_str 3883
dc.title.en_EN.fl_str_mv Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
dc.title.alternative.none.fl_str_mv Efficacité de la méthode d’électrocoagulation pour réduire la DCO, la DBO et les TSS dans les eaux usées de l’industrie du cuir: Application de la conception box-behnken
title Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
spellingShingle Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
Aguilar Ascón, Edwar
Electrocoagulation
Water treatment
Sewage
Curtido
Tanning
Electrocoagulación
Tratamiento del agua
https://purl.org/pe-repo/ocde/ford#2.11.04
title_short Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
title_full Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
title_fullStr Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
title_full_unstemmed Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
title_sort Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
author Aguilar Ascón, Edwar
author_facet Aguilar Ascón, Edwar
Marrufo Saldaña, Liliana
Neyra Ascón, Walter
author_role author
author2 Marrufo Saldaña, Liliana
Neyra Ascón, Walter
author2_role author
author
dc.contributor.other.none.fl_str_mv Aguilar Ascón, Edwar
Neyra Ascón, Walter
dc.contributor.author.fl_str_mv Aguilar Ascón, Edwar
Marrufo Saldaña, Liliana
Neyra Ascón, Walter
dc.subject.en_EN.fl_str_mv Electrocoagulation
Water treatment
Sewage
Curtido
Tanning
topic Electrocoagulation
Water treatment
Sewage
Curtido
Tanning
Electrocoagulación
Tratamiento del agua
https://purl.org/pe-repo/ocde/ford#2.11.04
dc.subject.es_PE.fl_str_mv Electrocoagulación
Tratamiento del agua
dc.subject.ocde.none.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.11.04
description This study intends to assess the removal efficiency of the chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total suspended solids (TSS) from raw tannery wastewater using electrocoagulation by aluminum electrodes as well as to determine the effects of its main operating factors. Therefore, the response surface methodology was applied through an experimental Box–Behnken design by considering the current intensity (I), treatment time (T), and pH levels as the factors. In addition, the BOD, COD, and TSS removal percentages were considered to be the response variables. The results indicate that the treatment time, current intensity, and pH level were significant for COD and TSS, whereas only the treatment time was significant at a confidence level of p-value < 0.05 for BOD. For COD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 8.4; for BOD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 5.5; and for TSS, the optimal operating conditions were I = 2.7 A, T = 19 min, and pH = 7.4. Under these conditions, removal efficiencies of 56.8%, 69.2%, 99.9% were observed for COD, BOD, and TSS, respectively. The results suggest that electrocoagulation is an effective method for removing the parameters under study; therefore, it is a viable alternative for reducing the pollution issues caused by the tannery industry.
publishDate 2020
dc.date.accessioned.none.fl_str_mv 2020-11-16T16:18:53Z
dc.date.available.none.fl_str_mv 2020-11-16T16:18:53Z
dc.date.issued.fl_str_mv 2020
dc.type.none.fl_str_mv info:eu-repo/semantics/article
dc.type.other.none.fl_str_mv Artículo en Scopus
format article
dc.identifier.citation.es_PE.fl_str_mv Aguilar-Ascón, E., Marrufo-Saldaña, L. & Neyra-Ascón, W. (2020). Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design. Revista de Pielarie Incaltaminte (Leather and Footwear Journal), 20(3), 217-228. https://doi.org/10.24264/lfj.20.3.1
dc.identifier.issn.none.fl_str_mv 1583-4433
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12724/11847
dc.identifier.journal.none.fl_str_mv Revista de Pielarie Incaltaminte (Leather and Footwear Journal)
dc.identifier.isni.none.fl_str_mv 0000000121541816
dc.identifier.doi.none.fl_str_mv https://doi.org/10.24264/lfj.20.3.1
dc.identifier.scopusid.none.fl_str_mv 2-s2.0-85095726716
identifier_str_mv Aguilar-Ascón, E., Marrufo-Saldaña, L. & Neyra-Ascón, W. (2020). Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design. Revista de Pielarie Incaltaminte (Leather and Footwear Journal), 20(3), 217-228. https://doi.org/10.24264/lfj.20.3.1
1583-4433
Revista de Pielarie Incaltaminte (Leather and Footwear Journal)
0000000121541816
2-s2.0-85095726716
url https://hdl.handle.net/20.500.12724/11847
https://doi.org/10.24264/lfj.20.3.1
dc.language.iso.none.fl_str_mv eng
language eng
dc.relation.ispartof.none.fl_str_mv urn:issn.1583-4433
dc.rights.*.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv https://creativecommons.org/licenses/by-nc-sa/4.0/
eu_rights_str_mv openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-sa/4.0/
dc.format.none.fl_str_mv application/html
dc.publisher.none.fl_str_mv Institutional National de Cercetare-Dezvoltare Pentru Texttile Pielarie
dc.publisher.country.none.fl_str_mv RO
publisher.none.fl_str_mv Institutional National de Cercetare-Dezvoltare Pentru Texttile Pielarie
dc.source.none.fl_str_mv Repositorio Institucional - Ulima
Universidad de Lima
reponame:ULIMA-Institucional
instname:Universidad de Lima
instacron:ULIMA
instname_str Universidad de Lima
instacron_str ULIMA
institution ULIMA
reponame_str ULIMA-Institucional
collection ULIMA-Institucional
bitstream.url.fl_str_mv https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/3/license.txt
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/2/license_rdf
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
8fc46f5e71650fd7adee84a69b9163c2
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Repositorio Universidad de Lima
repository.mail.fl_str_mv repositorio@ulima.edu.pe
_version_ 1846612007484129280
spelling Aguilar Ascón, EdwarMarrufo Saldaña, LilianaNeyra Ascón, WalterAguilar Ascón, EdwarNeyra Ascón, Walter2020-11-16T16:18:53Z2020-11-16T16:18:53Z2020Aguilar-Ascón, E., Marrufo-Saldaña, L. & Neyra-Ascón, W. (2020). Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design. Revista de Pielarie Incaltaminte (Leather and Footwear Journal), 20(3), 217-228. https://doi.org/10.24264/lfj.20.3.11583-4433https://hdl.handle.net/20.500.12724/11847Revista de Pielarie Incaltaminte (Leather and Footwear Journal)0000000121541816https://doi.org/10.24264/lfj.20.3.12-s2.0-85095726716This study intends to assess the removal efficiency of the chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total suspended solids (TSS) from raw tannery wastewater using electrocoagulation by aluminum electrodes as well as to determine the effects of its main operating factors. Therefore, the response surface methodology was applied through an experimental Box–Behnken design by considering the current intensity (I), treatment time (T), and pH levels as the factors. In addition, the BOD, COD, and TSS removal percentages were considered to be the response variables. The results indicate that the treatment time, current intensity, and pH level were significant for COD and TSS, whereas only the treatment time was significant at a confidence level of p-value < 0.05 for BOD. For COD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 8.4; for BOD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 5.5; and for TSS, the optimal operating conditions were I = 2.7 A, T = 19 min, and pH = 7.4. Under these conditions, removal efficiencies of 56.8%, 69.2%, 99.9% were observed for COD, BOD, and TSS, respectively. The results suggest that electrocoagulation is an effective method for removing the parameters under study; therefore, it is a viable alternative for reducing the pollution issues caused by the tannery industry.application/htmlengInstitutional National de Cercetare-Dezvoltare Pentru Texttile PielarieROurn:issn.1583-4433info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/4.0/Repositorio Institucional - UlimaUniversidad de Limareponame:ULIMA-Institucionalinstname:Universidad de Limainstacron:ULIMAElectrocoagulationWater treatmentSewageCurtidoTanningElectrocoagulaciónTratamiento del aguahttps://purl.org/pe-repo/ocde/ford#2.11.04Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken designEfficacité de la méthode d’électrocoagulation pour réduire la DCO, la DBO et les TSS dans les eaux usées de l’industrie du cuir: Application de la conception box-behnkeninfo:eu-repo/semantics/articleArtículo en ScopusNeyra Ascón, Walter (No figura en la lista del año 2020)Aguilar Ascón, Edwar (Universidad de Lima, Instituto de Investigación Científica - IDIC)Aguilar Ascón, Edwar (Programa de Estudios Generales)Neyra Ascón, Walter (Universidad de Lima, Instituto de Investigación Científica - IDIC)OILICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/3/license.txt8a4605be74aa9ea9d79846c1fba20a33MD53CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81037https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/2/license_rdf8fc46f5e71650fd7adee84a69b9163c2MD5220.500.12724/11847oai:repositorio.ulima.edu.pe:20.500.12724/118472025-03-06 19:29:02.753Repositorio Universidad de Limarepositorio@ulima.edu.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
score 13.088951
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).