Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design
Descripción del Articulo
This study intends to assess the removal efficiency of the chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total suspended solids (TSS) from raw tannery wastewater using electrocoagulation by aluminum electrodes as well as to determine the effects of its main operating factors. Th...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2020 |
| Institución: | Universidad de Lima |
| Repositorio: | ULIMA-Institucional |
| Lenguaje: | inglés |
| OAI Identifier: | oai:repositorio.ulima.edu.pe:20.500.12724/11847 |
| Enlace del recurso: | https://hdl.handle.net/20.500.12724/11847 https://doi.org/10.24264/lfj.20.3.1 |
| Nivel de acceso: | acceso abierto |
| Materia: | Electrocoagulation Water treatment Sewage Curtido Tanning Electrocoagulación Tratamiento del agua https://purl.org/pe-repo/ocde/ford#2.11.04 |
| id |
RULI_5dcfdce582805efb8a9e8d9ad5f1e3ba |
|---|---|
| oai_identifier_str |
oai:repositorio.ulima.edu.pe:20.500.12724/11847 |
| network_acronym_str |
RULI |
| network_name_str |
ULIMA-Institucional |
| repository_id_str |
3883 |
| dc.title.en_EN.fl_str_mv |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design |
| dc.title.alternative.none.fl_str_mv |
Efficacité de la méthode d’électrocoagulation pour réduire la DCO, la DBO et les TSS dans les eaux usées de l’industrie du cuir: Application de la conception box-behnken |
| title |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design |
| spellingShingle |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design Aguilar Ascón, Edwar Electrocoagulation Water treatment Sewage Curtido Tanning Electrocoagulación Tratamiento del agua https://purl.org/pe-repo/ocde/ford#2.11.04 |
| title_short |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design |
| title_full |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design |
| title_fullStr |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design |
| title_full_unstemmed |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design |
| title_sort |
Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design |
| author |
Aguilar Ascón, Edwar |
| author_facet |
Aguilar Ascón, Edwar Marrufo Saldaña, Liliana Neyra Ascón, Walter |
| author_role |
author |
| author2 |
Marrufo Saldaña, Liliana Neyra Ascón, Walter |
| author2_role |
author author |
| dc.contributor.other.none.fl_str_mv |
Aguilar Ascón, Edwar Neyra Ascón, Walter |
| dc.contributor.author.fl_str_mv |
Aguilar Ascón, Edwar Marrufo Saldaña, Liliana Neyra Ascón, Walter |
| dc.subject.en_EN.fl_str_mv |
Electrocoagulation Water treatment Sewage Curtido Tanning |
| topic |
Electrocoagulation Water treatment Sewage Curtido Tanning Electrocoagulación Tratamiento del agua https://purl.org/pe-repo/ocde/ford#2.11.04 |
| dc.subject.es_PE.fl_str_mv |
Electrocoagulación Tratamiento del agua |
| dc.subject.ocde.none.fl_str_mv |
https://purl.org/pe-repo/ocde/ford#2.11.04 |
| description |
This study intends to assess the removal efficiency of the chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total suspended solids (TSS) from raw tannery wastewater using electrocoagulation by aluminum electrodes as well as to determine the effects of its main operating factors. Therefore, the response surface methodology was applied through an experimental Box–Behnken design by considering the current intensity (I), treatment time (T), and pH levels as the factors. In addition, the BOD, COD, and TSS removal percentages were considered to be the response variables. The results indicate that the treatment time, current intensity, and pH level were significant for COD and TSS, whereas only the treatment time was significant at a confidence level of p-value < 0.05 for BOD. For COD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 8.4; for BOD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 5.5; and for TSS, the optimal operating conditions were I = 2.7 A, T = 19 min, and pH = 7.4. Under these conditions, removal efficiencies of 56.8%, 69.2%, 99.9% were observed for COD, BOD, and TSS, respectively. The results suggest that electrocoagulation is an effective method for removing the parameters under study; therefore, it is a viable alternative for reducing the pollution issues caused by the tannery industry. |
| publishDate |
2020 |
| dc.date.accessioned.none.fl_str_mv |
2020-11-16T16:18:53Z |
| dc.date.available.none.fl_str_mv |
2020-11-16T16:18:53Z |
| dc.date.issued.fl_str_mv |
2020 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.other.none.fl_str_mv |
Artículo en Scopus |
| format |
article |
| dc.identifier.citation.es_PE.fl_str_mv |
Aguilar-Ascón, E., Marrufo-Saldaña, L. & Neyra-Ascón, W. (2020). Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design. Revista de Pielarie Incaltaminte (Leather and Footwear Journal), 20(3), 217-228. https://doi.org/10.24264/lfj.20.3.1 |
| dc.identifier.issn.none.fl_str_mv |
1583-4433 |
| dc.identifier.uri.none.fl_str_mv |
https://hdl.handle.net/20.500.12724/11847 |
| dc.identifier.journal.none.fl_str_mv |
Revista de Pielarie Incaltaminte (Leather and Footwear Journal) |
| dc.identifier.isni.none.fl_str_mv |
0000000121541816 |
| dc.identifier.doi.none.fl_str_mv |
https://doi.org/10.24264/lfj.20.3.1 |
| dc.identifier.scopusid.none.fl_str_mv |
2-s2.0-85095726716 |
| identifier_str_mv |
Aguilar-Ascón, E., Marrufo-Saldaña, L. & Neyra-Ascón, W. (2020). Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design. Revista de Pielarie Incaltaminte (Leather and Footwear Journal), 20(3), 217-228. https://doi.org/10.24264/lfj.20.3.1 1583-4433 Revista de Pielarie Incaltaminte (Leather and Footwear Journal) 0000000121541816 2-s2.0-85095726716 |
| url |
https://hdl.handle.net/20.500.12724/11847 https://doi.org/10.24264/lfj.20.3.1 |
| dc.language.iso.none.fl_str_mv |
eng |
| language |
eng |
| dc.relation.ispartof.none.fl_str_mv |
urn:issn.1583-4433 |
| dc.rights.*.fl_str_mv |
info:eu-repo/semantics/openAccess |
| dc.rights.uri.*.fl_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0/ |
| dc.format.none.fl_str_mv |
application/html |
| dc.publisher.none.fl_str_mv |
Institutional National de Cercetare-Dezvoltare Pentru Texttile Pielarie |
| dc.publisher.country.none.fl_str_mv |
RO |
| publisher.none.fl_str_mv |
Institutional National de Cercetare-Dezvoltare Pentru Texttile Pielarie |
| dc.source.none.fl_str_mv |
Repositorio Institucional - Ulima Universidad de Lima reponame:ULIMA-Institucional instname:Universidad de Lima instacron:ULIMA |
| instname_str |
Universidad de Lima |
| instacron_str |
ULIMA |
| institution |
ULIMA |
| reponame_str |
ULIMA-Institucional |
| collection |
ULIMA-Institucional |
| bitstream.url.fl_str_mv |
https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/3/license.txt https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/2/license_rdf |
| bitstream.checksum.fl_str_mv |
8a4605be74aa9ea9d79846c1fba20a33 8fc46f5e71650fd7adee84a69b9163c2 |
| bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
| repository.name.fl_str_mv |
Repositorio Universidad de Lima |
| repository.mail.fl_str_mv |
repositorio@ulima.edu.pe |
| _version_ |
1846612007484129280 |
| spelling |
Aguilar Ascón, EdwarMarrufo Saldaña, LilianaNeyra Ascón, WalterAguilar Ascón, EdwarNeyra Ascón, Walter2020-11-16T16:18:53Z2020-11-16T16:18:53Z2020Aguilar-Ascón, E., Marrufo-Saldaña, L. & Neyra-Ascón, W. (2020). Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken design. Revista de Pielarie Incaltaminte (Leather and Footwear Journal), 20(3), 217-228. https://doi.org/10.24264/lfj.20.3.11583-4433https://hdl.handle.net/20.500.12724/11847Revista de Pielarie Incaltaminte (Leather and Footwear Journal)0000000121541816https://doi.org/10.24264/lfj.20.3.12-s2.0-85095726716This study intends to assess the removal efficiency of the chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total suspended solids (TSS) from raw tannery wastewater using electrocoagulation by aluminum electrodes as well as to determine the effects of its main operating factors. Therefore, the response surface methodology was applied through an experimental Box–Behnken design by considering the current intensity (I), treatment time (T), and pH levels as the factors. In addition, the BOD, COD, and TSS removal percentages were considered to be the response variables. The results indicate that the treatment time, current intensity, and pH level were significant for COD and TSS, whereas only the treatment time was significant at a confidence level of p-value < 0.05 for BOD. For COD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 8.4; for BOD, the optimal operating conditions were I = 3 A, T = 24 min, and pH = 5.5; and for TSS, the optimal operating conditions were I = 2.7 A, T = 19 min, and pH = 7.4. Under these conditions, removal efficiencies of 56.8%, 69.2%, 99.9% were observed for COD, BOD, and TSS, respectively. The results suggest that electrocoagulation is an effective method for removing the parameters under study; therefore, it is a viable alternative for reducing the pollution issues caused by the tannery industry.application/htmlengInstitutional National de Cercetare-Dezvoltare Pentru Texttile PielarieROurn:issn.1583-4433info:eu-repo/semantics/openAccesshttps://creativecommons.org/licenses/by-nc-sa/4.0/Repositorio Institucional - UlimaUniversidad de Limareponame:ULIMA-Institucionalinstname:Universidad de Limainstacron:ULIMAElectrocoagulationWater treatmentSewageCurtidoTanningElectrocoagulaciónTratamiento del aguahttps://purl.org/pe-repo/ocde/ford#2.11.04Efficiency of electrocoagulation method to reduce COD, BOD and TSS in tannery industry wastewater: Application of the box–behnken designEfficacité de la méthode d’électrocoagulation pour réduire la DCO, la DBO et les TSS dans les eaux usées de l’industrie du cuir: Application de la conception box-behnkeninfo:eu-repo/semantics/articleArtículo en ScopusNeyra Ascón, Walter (No figura en la lista del año 2020)Aguilar Ascón, Edwar (Universidad de Lima, Instituto de Investigación Científica - IDIC)Aguilar Ascón, Edwar (Programa de Estudios Generales)Neyra Ascón, Walter (Universidad de Lima, Instituto de Investigación Científica - IDIC)OILICENSElicense.txtlicense.txttext/plain; charset=utf-81748https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/3/license.txt8a4605be74aa9ea9d79846c1fba20a33MD53CC-LICENSElicense_rdflicense_rdfapplication/rdf+xml; charset=utf-81037https://repositorio.ulima.edu.pe/bitstream/20.500.12724/11847/2/license_rdf8fc46f5e71650fd7adee84a69b9163c2MD5220.500.12724/11847oai:repositorio.ulima.edu.pe:20.500.12724/118472025-03-06 19:29:02.753Repositorio Universidad de Limarepositorio@ulima.edu.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 |
| score |
13.088951 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).