Irregularly sampled data in the design of a soft sensor system: some preliminary results

Descripción del Articulo

In modern industrial applications, sensors are an expensive part of installed systems. Nevertheless, many system variables cannot be measured sufficiently frequently or accurately. Thus, soft sensors have been developed to estimate those variables without the expense of additional hardware. The use...

Descripción completa

Detalles Bibliográficos
Autor: Griesing-Scheiwe, Fritjof
Formato: tesis de maestría
Fecha de Publicación:2018
Institución:Pontificia Universidad Católica del Perú
Repositorio:PUCP-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.pucp.edu.pe:20.500.14657/146008
Enlace del recurso:http://hdl.handle.net/20.500.12404/13295
Nivel de acceso:acceso abierto
Materia:Sensores--Programas para computadoras
Sensores--Computación flexible
Control de procesos
https://purl.org/pe-repo/ocde/ford#2.02.03
id RPUC_47f7b7460ace2f44afa4cbe07d501c90
oai_identifier_str oai:repositorio.pucp.edu.pe:20.500.14657/146008
network_acronym_str RPUC
network_name_str PUCP-Institucional
repository_id_str 2905
spelling Pérez Zúñiga, Carlos GustavoGriesing-Scheiwe, Fritjof2019-01-24T21:03:08Z2019-01-24T21:03:08Z20182019-01-21http://hdl.handle.net/20.500.12404/13295In modern industrial applications, sensors are an expensive part of installed systems. Nevertheless, many system variables cannot be measured sufficiently frequently or accurately. Thus, soft sensors have been developed to estimate those variables without the expense of additional hardware. The use of a soft sensor with a bias update term has shown to perform well for disturbed systems with time delays and multirate sampling times. In industrial application, the time delay and sampling times often vary. Yet, the case of variation of the time delay and sampling time in the bias update term has not been considered in previous publications. This thesis tests a soft sensor with bias update term in simulation and gives a modification yielding better performance. It is shown that the tested method gives unstable results. Hence, a more general method with a bias update term that considers all possible sampling times in each step is proposed, giving stable results in simulation. Furthermore, the stability of the general method is proven mathematically by building a state space representation and applyingTesisengPontificia Universidad Católica del PerúPEinfo:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-sa/2.5/pe/Sensores--Programas para computadorasSensores--Computación flexibleControl de procesoshttps://purl.org/pe-repo/ocde/ford#2.02.03Irregularly sampled data in the design of a soft sensor system: some preliminary resultsinfo:eu-repo/semantics/masterThesisTesis de maestríareponame:PUCP-Institucionalinstname:Pontificia Universidad Católica del Perúinstacron:PUCPMaestro en Ingeniería de Control y AutomatizaciónMaestríaPontificia Universidad Católica del Perú. Escuela de PosgradoIngeniería de Control y Automatización41864666712037https://purl.org/pe-repo/renati/level#maestrohttp://purl.org/pe-repo/renati/type#tesis20.500.14657/146008oai:repositorio.pucp.edu.pe:20.500.14657/1460082024-06-10 10:28:59.254http://creativecommons.org/licenses/by-sa/2.5/pe/info:eu-repo/semantics/openAccessmetadata.onlyhttps://repositorio.pucp.edu.peRepositorio Institucional de la PUCPrepositorio@pucp.pe
dc.title.es_ES.fl_str_mv Irregularly sampled data in the design of a soft sensor system: some preliminary results
title Irregularly sampled data in the design of a soft sensor system: some preliminary results
spellingShingle Irregularly sampled data in the design of a soft sensor system: some preliminary results
Griesing-Scheiwe, Fritjof
Sensores--Programas para computadoras
Sensores--Computación flexible
Control de procesos
https://purl.org/pe-repo/ocde/ford#2.02.03
title_short Irregularly sampled data in the design of a soft sensor system: some preliminary results
title_full Irregularly sampled data in the design of a soft sensor system: some preliminary results
title_fullStr Irregularly sampled data in the design of a soft sensor system: some preliminary results
title_full_unstemmed Irregularly sampled data in the design of a soft sensor system: some preliminary results
title_sort Irregularly sampled data in the design of a soft sensor system: some preliminary results
author Griesing-Scheiwe, Fritjof
author_facet Griesing-Scheiwe, Fritjof
author_role author
dc.contributor.advisor.fl_str_mv Pérez Zúñiga, Carlos Gustavo
dc.contributor.author.fl_str_mv Griesing-Scheiwe, Fritjof
dc.subject.es_ES.fl_str_mv Sensores--Programas para computadoras
Sensores--Computación flexible
Control de procesos
topic Sensores--Programas para computadoras
Sensores--Computación flexible
Control de procesos
https://purl.org/pe-repo/ocde/ford#2.02.03
dc.subject.ocde.es_ES.fl_str_mv https://purl.org/pe-repo/ocde/ford#2.02.03
description In modern industrial applications, sensors are an expensive part of installed systems. Nevertheless, many system variables cannot be measured sufficiently frequently or accurately. Thus, soft sensors have been developed to estimate those variables without the expense of additional hardware. The use of a soft sensor with a bias update term has shown to perform well for disturbed systems with time delays and multirate sampling times. In industrial application, the time delay and sampling times often vary. Yet, the case of variation of the time delay and sampling time in the bias update term has not been considered in previous publications. This thesis tests a soft sensor with bias update term in simulation and gives a modification yielding better performance. It is shown that the tested method gives unstable results. Hence, a more general method with a bias update term that considers all possible sampling times in each step is proposed, giving stable results in simulation. Furthermore, the stability of the general method is proven mathematically by building a state space representation and applying
publishDate 2018
dc.date.created.es_ES.fl_str_mv 2018
dc.date.accessioned.es_ES.fl_str_mv 2019-01-24T21:03:08Z
dc.date.available.es_ES.fl_str_mv 2019-01-24T21:03:08Z
dc.date.issued.fl_str_mv 2019-01-21
dc.type.es_ES.fl_str_mv info:eu-repo/semantics/masterThesis
dc.type.other.none.fl_str_mv Tesis de maestría
format masterThesis
dc.identifier.uri.none.fl_str_mv http://hdl.handle.net/20.500.12404/13295
url http://hdl.handle.net/20.500.12404/13295
dc.language.iso.es_ES.fl_str_mv eng
language eng
dc.rights.es_ES.fl_str_mv info:eu-repo/semantics/openAccess
dc.rights.uri.*.fl_str_mv http://creativecommons.org/licenses/by-sa/2.5/pe/
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-sa/2.5/pe/
dc.publisher.es_ES.fl_str_mv Pontificia Universidad Católica del Perú
dc.publisher.country.es_ES.fl_str_mv PE
dc.source.none.fl_str_mv reponame:PUCP-Institucional
instname:Pontificia Universidad Católica del Perú
instacron:PUCP
instname_str Pontificia Universidad Católica del Perú
instacron_str PUCP
institution PUCP
reponame_str PUCP-Institucional
collection PUCP-Institucional
repository.name.fl_str_mv Repositorio Institucional de la PUCP
repository.mail.fl_str_mv repositorio@pucp.pe
_version_ 1835639702995075072
score 13.982926
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).