Evaluation of Elastographic techniques generated by means of external vibration

Descripción del Articulo

Breast cancer is one of the greatest problems of national and international public health, whose incidence among women population shows an increasing trend. Nowadays there are several elastographic techniques, which seek to characterize the tissue, that is, to analyze the response produced by the ap...

Descripción completa

Detalles Bibliográficos
Autor: Arroyo Barboza, Johnny Junior
Formato: tesis de maestría
Fecha de Publicación:2017
Institución:Pontificia Universidad Católica del Perú
Repositorio:PUCP-Institucional
Lenguaje:inglés
OAI Identifier:oai:repositorio.pucp.edu.pe:20.500.14657/146489
Enlace del recurso:http://hdl.handle.net/20.500.12404/9821
Nivel de acceso:acceso abierto
Materia:Holografía
Ultrasonido--Vibración
Ingeniería de tejidos
Cáncer
https://purl.org/pe-repo/ocde/ford#2.02.05
Descripción
Sumario:Breast cancer is one of the greatest problems of national and international public health, whose incidence among women population shows an increasing trend. Nowadays there are several elastographic techniques, which seek to characterize the tissue, that is, to analyze the response produced by the application of a perturbation in the medium, to describe its mechanical properties. Among the modalities used are ultrasound, nuclear magnetic resonance and optical coherence tomography. On the other hand, among the types of disturbance used are low frequency mechanical waves, a uniform compression force or acoustic radiation force. In this thesis work, ultrasound was used due to its low economical cost in comparison to the other modalities. In addition, the type of perturbation selected was the external mechanical vibration, as it ensures the achievement of quantitative results, there is no risk of temperature rise in the analyzed area and allows the repeatability of the results obtained. Hence, two elastographic techniques were the axes of the present work: vibro-elastography and normal vibration holography. For the first, a calibrated phantom and a gelatin-based phantom were used, in order to characterize and validate the technique over a wide range of excitation frequencies. Posteriorly, 18 patients were analyzed prior biopsy exam, obtaining elastograms and contrasting them with the respective biopsy results. The results suggest that the technique is able to identify the presence of benign or malignant cancer, and the elasticity estimated agree with values reported in the literature. The second technique is proposed in the elastography field for the first time. Based on holography, its experimental scheme is established, and the mathematical expression for shear speed estimation is presented. Results from simulation and experiments performed on homogeneous and heterogeneous phantoms are presented, and the estimates are compared with previously obtained reference values. The results suggest that the estimates are close to the reference values for all media tested, and the technique must be studied in depth to revert artifacts formation.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).