Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography
Descripción del Articulo
Objective: To determine the amount of transportation and the centering ability by nickel titanium rotary systems Mtwo and Twisted File, in mesial roots of lower molars using Cone Beam computed tomography. Materials and Methods: Sixty mesial canals of mandibular molars with severe angles of curvature...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Universidad de San Martín de Porres |
Repositorio: | Revistas - Universidad de San Martín de Porres |
Lenguaje: | español |
OAI Identifier: | oai:revistas.usmp.edu.pe:article/1658 |
Enlace del recurso: | https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658 |
Nivel de acceso: | acceso abierto |
Materia: | Canal transportation Cone Beam – computed tomography nickel titanium. Transporte del conducto tomografía computarizada de haz cónico níquel titanio |
id |
REVUSMP_578f88f728fae03b8976aa116ff9b0d2 |
---|---|
oai_identifier_str |
oai:revistas.usmp.edu.pe:article/1658 |
network_acronym_str |
REVUSMP |
network_name_str |
Revistas - Universidad de San Martín de Porres |
repository_id_str |
|
spelling |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomographyTransporte y centricidad de los sistemas mtwo y twisted file evaluados mediante tomografía computarizada cone-beamTorres Carrillo, Angelo José SócratesMendoza Porres, RonaldCanal transportationCone Beam – computed tomographynickel titanium.Transporte del conductotomografía computarizada de haz cóniconíquel titanioObjective: To determine the amount of transportation and the centering ability by nickel titanium rotary systems Mtwo and Twisted File, in mesial roots of lower molars using Cone Beam computed tomography. Materials and Methods: Sixty mesial canals of mandibular molars with severe angles of curvature were divided into two groups. After the instrumentation with rotary systems Mtwo and Twisted File, the amount of transportation and centering capacity were evaluated using cone beam computed tomography. Two sections from middle and cervical levels of the canal were recorded. Student t-tests and U by Mann Whitney tests were used for statistical analysis. Results: Less transportation and better centering ability occurred with Twisted File rotary instruments. However, there was no statistically significant difference between the systems (p≤0.05). Canals were transported mostly towards the mesial aspect in the cervical third of the roots, and towards the distal aspect in the mesial third. Conclusions: The rotary instruments Mtwo and Twisted File behaved similarly about the canal transportation and centering, allowing the preparation of curved canals with little deviation.Objetivos: Determinar la cantidad de transporte y capacidad de centrado de los sistemas rotatorios Mtwo y Twisted File, en raíces mesiales de molares inferiores usando tomografía computarizada Cone Beam. Materiales y Métodos: Sesenta conductos mesiales de molares inferiores con ángulos severos de curvatura fueron divididos en dos grupos. Después de la instrumentación con los sistemas rotatorios Mtwo y Twisted File, se evaluó la cantidad de transporte y capacidad de centrado mediante tomografía computarizada Cone Beam. Se registraron dos secciones a nivel del tercio medio y cervical del conducto. Pruebas de T de Student y U de Mann Whitney se utilizaron para el análisis estadístico. Resultados: Menor transporte y mejor centricidad se obtuvieron con los instrumentos rotatorios Twisted File. Sin embargo, no hubo diferencias estadísticamente significativas entre los sistemas (p≤0.05). Los conductos se transportaron principalmente hacia mesial en el tercio cervical de la raíz y hacia distal en el tercio medio. Conclusiones: Los instrumentos rotatorios Mtwo y Twisted File se comportaron de manera similar en cuanto al transporte y centricidad, permitiendo la preparación de conductos curvos con poca desviación.Universidad de San Martín de Porres, Facultad de Odontología.2019-10-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/xmlhttps://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658KIRU ; Vol. 16 No. 4 (2019): kiru (Octubre-Diciembre) KIRU ISSN electrónico 2410-2717 ISSN Impreso 1812 - 7886; Vol. 16 Núm. 4 (2019): kiru (Octubre-Diciembre)2410-27171812-7886reponame:Revistas - Universidad de San Martín de Porresinstname:Universidad de San Martín de Porresinstacron:USMPspahttps://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658/Transporte%20y%20centricidad%20de%20los%20sistemas%20mtwo%20y%20twisted%20file%20evaluados%20mediante%20tomograf%C3%ADa%20computarizada%20cone-beamhttps://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658/xml_1Derechos de autor 2019 Revista KIRUinfo:eu-repo/semantics/openAccessoai:revistas.usmp.edu.pe:article/16582020-02-05T19:01:37Z |
dc.title.none.fl_str_mv |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography Transporte y centricidad de los sistemas mtwo y twisted file evaluados mediante tomografía computarizada cone-beam |
title |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography |
spellingShingle |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography Torres Carrillo, Angelo José Sócrates Canal transportation Cone Beam – computed tomography nickel titanium. Transporte del conducto tomografía computarizada de haz cónico níquel titanio |
title_short |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography |
title_full |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography |
title_fullStr |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography |
title_full_unstemmed |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography |
title_sort |
Transportation and centering of mtwo and twisted file systems evaluated by cone beam computed tomography |
dc.creator.none.fl_str_mv |
Torres Carrillo, Angelo José Sócrates Mendoza Porres, Ronald |
author |
Torres Carrillo, Angelo José Sócrates |
author_facet |
Torres Carrillo, Angelo José Sócrates Mendoza Porres, Ronald |
author_role |
author |
author2 |
Mendoza Porres, Ronald |
author2_role |
author |
dc.subject.none.fl_str_mv |
Canal transportation Cone Beam – computed tomography nickel titanium. Transporte del conducto tomografía computarizada de haz cónico níquel titanio |
topic |
Canal transportation Cone Beam – computed tomography nickel titanium. Transporte del conducto tomografía computarizada de haz cónico níquel titanio |
description |
Objective: To determine the amount of transportation and the centering ability by nickel titanium rotary systems Mtwo and Twisted File, in mesial roots of lower molars using Cone Beam computed tomography. Materials and Methods: Sixty mesial canals of mandibular molars with severe angles of curvature were divided into two groups. After the instrumentation with rotary systems Mtwo and Twisted File, the amount of transportation and centering capacity were evaluated using cone beam computed tomography. Two sections from middle and cervical levels of the canal were recorded. Student t-tests and U by Mann Whitney tests were used for statistical analysis. Results: Less transportation and better centering ability occurred with Twisted File rotary instruments. However, there was no statistically significant difference between the systems (p≤0.05). Canals were transported mostly towards the mesial aspect in the cervical third of the roots, and towards the distal aspect in the mesial third. Conclusions: The rotary instruments Mtwo and Twisted File behaved similarly about the canal transportation and centering, allowing the preparation of curved canals with little deviation. |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-10-06 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658 |
url |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658/Transporte%20y%20centricidad%20de%20los%20sistemas%20mtwo%20y%20twisted%20file%20evaluados%20mediante%20tomograf%C3%ADa%20computarizada%20cone-beam https://portalrevistas.aulavirtualusmp.pe/index.php/Rev-Kiru0/article/view/1658/xml_1 |
dc.rights.none.fl_str_mv |
Derechos de autor 2019 Revista KIRU info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2019 Revista KIRU |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf application/xml |
dc.publisher.none.fl_str_mv |
Universidad de San Martín de Porres, Facultad de Odontología. |
publisher.none.fl_str_mv |
Universidad de San Martín de Porres, Facultad de Odontología. |
dc.source.none.fl_str_mv |
KIRU ; Vol. 16 No. 4 (2019): kiru (Octubre-Diciembre) KIRU ISSN electrónico 2410-2717 ISSN Impreso 1812 - 7886; Vol. 16 Núm. 4 (2019): kiru (Octubre-Diciembre) 2410-2717 1812-7886 reponame:Revistas - Universidad de San Martín de Porres instname:Universidad de San Martín de Porres instacron:USMP |
instname_str |
Universidad de San Martín de Porres |
instacron_str |
USMP |
institution |
USMP |
reponame_str |
Revistas - Universidad de San Martín de Porres |
collection |
Revistas - Universidad de San Martín de Porres |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1844981169191387136 |
score |
12.636287 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).