Acute pneumonitis after subcutaneous injection of BIO-ALCAMID® in breast: Neumonitis aguda secundaria a la inyección subcutánea de gel de polialquilamida (BIO-ALCAMID) en mamas

Descripción del Articulo

ABSTRACT: Filling materials are used to correct soft tissue deficits. Local and systemic complications are described when these substances are applied. The polyalkylamide gel (Bio-alcamid) used as filler material has been associated with complications at the facial level, while at the pulmonary leve...

Descripción completa

Detalles Bibliográficos
Autores: Villanueva-Villegas, Renzo, Trigoso-Gutiérrez, Anita, Castillo-Gutierrez, Piero, Salas-López, Juan
Formato: artículo
Fecha de Publicación:2023
Institución:Universidad Ricardo Palma
Repositorio:Revistas - Universidad Ricardo Palma
Lenguaje:español
inglés
OAI Identifier:oai:oai.revistas.urp.edu.pe:article/4992
Enlace del recurso:http://revistas.urp.edu.pe/index.php/RFMH/article/view/4992
Nivel de acceso:acceso abierto
Materia:Neumonitis aguda
biopolímero
material de relleno
disnea
Acute pneumonitis
biopolymer
filler material
dyspnea
Descripción
Sumario:ABSTRACT: Filling materials are used to correct soft tissue deficits. Local and systemic complications are described when these substances are applied. The polyalkylamide gel (Bio-alcamid) used as filler material has been associated with complications at the facial level, while at the pulmonary level they have not been reported in the literature. We present the case of a patient who consulted due to sudden progressive dyspnea hours after the subcutaneous injection of Bio-alcamid in the breasts. After the clinical evaluation and the result of auxiliary tests, the diagnosis of acute pneumonitis secondary to the injection of this substance is concluded. Follow-up of the case was carried out with favorable evolution and resolution of symptoms after three months. We conclude that Bio-alcamid can generate complications at the pulmonary level, therefore, the intervention of public policies that regulate its use, commercialization and application by non-medical personnel is necessary.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).