Genetic Biomonitoring in Workers of the Radiology Service of National Police Hospital Luis N. Sáenz: Biomonitoreo Genético en Trabajadores del Servicio de Radiología del Hospital Nacional Policial Luis N. Sáenz
Descripción del Articulo
Objective: To evaluate the genotoxic effect on workers exposed to X-rays in the Radiology Service of the Luis N. Sáenz National Hospital PNP. Materials and methods. The type of study was observational, prospective, cross-sectional, analytical, using the comet assay as an analysis technique. The stud...
Autor: | |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Universidad Ricardo Palma |
Repositorio: | Revistas - Universidad Ricardo Palma |
Lenguaje: | español inglés |
OAI Identifier: | oai:oai.revistas.urp.edu.pe:article/2256 |
Enlace del recurso: | http://revistas.urp.edu.pe/index.php/RFMH/article/view/2256 |
Nivel de acceso: | acceso abierto |
Materia: | Genotoxic Exposure X-ray Comet test Occupational health Genotoxicidad Rayos X Ensayo cometa Salud laboral |
Sumario: | Objective: To evaluate the genotoxic effect on workers exposed to X-rays in the Radiology Service of the Luis N. Sáenz National Hospital PNP. Materials and methods. The type of study was observational, prospective, cross-sectional, analytical, using the comet assay as an analysis technique. The study population was 20 workers exposed to X-rays and 20 people without exposure. Results The mean length of migration of damaged DNA in the control group was 1.28 ± 0.38 µm and 10.39 ± 9.44 µm for the exposed group, the means of the groups were compared, obtaining p = 0.001 significant. The correlation analysis for DNA damage, years of exposure and dose received, a significant correlation was found (p <0.05). For the correlation of DNA damage with age, no statistical significance was found (p> 0.05). Conclusions X-rays at low permissible doses can cause damage to DNA integrity, correlating with the first years of exposure of personnel working in the radiology service. Keywords: Genotoxic, exposure, X-ray, comet test. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).