Seismic performance of a three-level health center with or without insulators

Descripción del Articulo

The present work deals with the seismic performance of a building (health center) of three levels with or without insulators, which aims to know the methodology applied, analyze the results obtained and establish considerations that must be taken into account in the design of the insulators. The pro...

Descripción completa

Detalles Bibliográficos
Autor: Arcaya Pancca, Pablo Cesar
Formato: artículo
Fecha de Publicación:2020
Institución:Universidad Privada de Tacna
Repositorio:Revistas - Universidad Privada de Tacna
Lenguaje:español
OAI Identifier:oai:revistas.upt.edu.pe:article/185
Enlace del recurso:https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185
Nivel de acceso:acceso abierto
Materia:Aisladores
edificio
Insulators
building
id REVUPT_d2a616c1a4849d343e45d42e42e33e79
oai_identifier_str oai:revistas.upt.edu.pe:article/185
network_acronym_str REVUPT
network_name_str Revistas - Universidad Privada de Tacna
repository_id_str
spelling Seismic performance of a three-level health center with or without insulatorsDesempeño sísmico de un centro de salud de tres niveles con o sin aisladoresArcaya Pancca, Pablo CesarAisladoresedificioInsulatorsbuildingThe present work deals with the seismic performance of a building (health center) of three levels with or without insulators, which aims to know the methodology applied, analyze the results obtained and establish considerations that must be taken into account in the design of the insulators. The problem to be measured was the seismic performance in a three-level health center with or without insulators, with the types of insulators to be considered three types: highdamping insulators (HDR), lead-core insulators (LRB) and frictional pendulum (FPS). The methodology used was applying the Chilean regulation NCh2745-2003, the same that is an adaptation of the "international code for buildings" (IBC), for its acronym in English "which is based on an American standard for the design of insulators and through the modeling of the structure with a computational program such as SAP 2000. The results obtained were for an uninsulated structure, from the first to the last level it has values of 0.35, 0.34 and 0.29 sec. of fundamental period, for the case with high damping insulators the values of 2.98, 2.97, 2.56 of fundamental period were obtained, for insulators with lead core the values were 2.76, 2.75 and 2.38 and for insulators with frictional pendulum system the values were 1.24, 1.22 and 1.06 respectively. When comparing the seismic performance of a structure it is better with insulators, in comparison with a structure without insulators, being the insulators of high damping of better seismic performanceEl presente trabajo trata sobre el desempeño sísmico de un edificio (centro de salud) de tres niveles con o sin aisladores, el cual tiene como objetivos conocer la metodología aplicada, analizar los resultados obtenidos y establecer consideraciones que se deben tener en cuenta en el diseño de los aisladores. El problema a medir fue el desempeño sísmico en un centro de salud de tres niveles con o sin aisladores, siendo los tipos de aisladores a considerar tres tipos: aisladores de alto amortiguamiento (HDR), aisladores con núcleo de plomo (LRB) y sistema de péndulo friccional (FPS). La metodología utilizada fue aplicando la normatividad chilena NCh2745-2003, el mismo que es una adaptación del “código internacional para edificios” (IBC), por sus siglas en ingles que se basa en una norma americana para el diseño de aisladores y a través del modelado de la estructura con una programa computacional como es el SAP 2000.Los resultados obtenidos fueron para una estructura sin aislación. Del primer al último nivel se tiene valores de 0.35, 0.34 y 0.29 seg. de periodo fundamental, para el caso con aisladores de alto amortiguamiento se obtuvieron los valores de 2.98, 2.97, 2.56 de periodo fundamental, para aisladores con núcleo de plomo los valores fueron de 2.76, 2.75 y 2.38 y para aisladores con sistema de péndulo friccional los valores eran 1.24, 1.22 y 1.06 respectivamente. Al comparar el desempeño sísmico de una estructura es mejor con aisladores, en comparación con una estructura sin aisladores, siendo los aisladores de alto amortiguamiento de mejor desempeño sísmicoUniversidad Privada de Tacna2020-04-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/18510.47796/ves.v6i2.185REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 No. 2 (2017): Veritas et Scientia; pp. 747 - 752REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 Núm. 2 (2017): Veritas et Scientia; pp. 747 - 7522617-06392307-513910.47796/ves.v6i2reponame:Revistas - Universidad Privada de Tacnainstname:Universidad Privada de Tacnainstacron:UPTspahttps://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185/169info:eu-repo/semantics/openAccessoai:revistas.upt.edu.pe:article/1852021-07-12T18:02:03Z
dc.title.none.fl_str_mv Seismic performance of a three-level health center with or without insulators
Desempeño sísmico de un centro de salud de tres niveles con o sin aisladores
title Seismic performance of a three-level health center with or without insulators
spellingShingle Seismic performance of a three-level health center with or without insulators
Arcaya Pancca, Pablo Cesar
Aisladores
edificio
Insulators
building
title_short Seismic performance of a three-level health center with or without insulators
title_full Seismic performance of a three-level health center with or without insulators
title_fullStr Seismic performance of a three-level health center with or without insulators
title_full_unstemmed Seismic performance of a three-level health center with or without insulators
title_sort Seismic performance of a three-level health center with or without insulators
dc.creator.none.fl_str_mv Arcaya Pancca, Pablo Cesar
author Arcaya Pancca, Pablo Cesar
author_facet Arcaya Pancca, Pablo Cesar
author_role author
dc.subject.none.fl_str_mv Aisladores
edificio
Insulators
building
topic Aisladores
edificio
Insulators
building
description The present work deals with the seismic performance of a building (health center) of three levels with or without insulators, which aims to know the methodology applied, analyze the results obtained and establish considerations that must be taken into account in the design of the insulators. The problem to be measured was the seismic performance in a three-level health center with or without insulators, with the types of insulators to be considered three types: highdamping insulators (HDR), lead-core insulators (LRB) and frictional pendulum (FPS). The methodology used was applying the Chilean regulation NCh2745-2003, the same that is an adaptation of the "international code for buildings" (IBC), for its acronym in English "which is based on an American standard for the design of insulators and through the modeling of the structure with a computational program such as SAP 2000. The results obtained were for an uninsulated structure, from the first to the last level it has values of 0.35, 0.34 and 0.29 sec. of fundamental period, for the case with high damping insulators the values of 2.98, 2.97, 2.56 of fundamental period were obtained, for insulators with lead core the values were 2.76, 2.75 and 2.38 and for insulators with frictional pendulum system the values were 1.24, 1.22 and 1.06 respectively. When comparing the seismic performance of a structure it is better with insulators, in comparison with a structure without insulators, being the insulators of high damping of better seismic performance
publishDate 2020
dc.date.none.fl_str_mv 2020-04-29
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185
10.47796/ves.v6i2.185
url https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185
identifier_str_mv 10.47796/ves.v6i2.185
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185/169
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Privada de Tacna
publisher.none.fl_str_mv Universidad Privada de Tacna
dc.source.none.fl_str_mv REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 No. 2 (2017): Veritas et Scientia; pp. 747 - 752
REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 Núm. 2 (2017): Veritas et Scientia; pp. 747 - 752
2617-0639
2307-5139
10.47796/ves.v6i2
reponame:Revistas - Universidad Privada de Tacna
instname:Universidad Privada de Tacna
instacron:UPT
instname_str Universidad Privada de Tacna
instacron_str UPT
institution UPT
reponame_str Revistas - Universidad Privada de Tacna
collection Revistas - Universidad Privada de Tacna
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1842353616959045632
score 12.659675
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).