Seismic performance of a three-level health center with or without insulators
Descripción del Articulo
The present work deals with the seismic performance of a building (health center) of three levels with or without insulators, which aims to know the methodology applied, analyze the results obtained and establish considerations that must be taken into account in the design of the insulators. The pro...
Autor: | |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2020 |
Institución: | Universidad Privada de Tacna |
Repositorio: | Revistas - Universidad Privada de Tacna |
Lenguaje: | español |
OAI Identifier: | oai:revistas.upt.edu.pe:article/185 |
Enlace del recurso: | https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185 |
Nivel de acceso: | acceso abierto |
Materia: | Aisladores edificio Insulators building |
id |
REVUPT_d2a616c1a4849d343e45d42e42e33e79 |
---|---|
oai_identifier_str |
oai:revistas.upt.edu.pe:article/185 |
network_acronym_str |
REVUPT |
network_name_str |
Revistas - Universidad Privada de Tacna |
repository_id_str |
|
spelling |
Seismic performance of a three-level health center with or without insulatorsDesempeño sísmico de un centro de salud de tres niveles con o sin aisladoresArcaya Pancca, Pablo CesarAisladoresedificioInsulatorsbuildingThe present work deals with the seismic performance of a building (health center) of three levels with or without insulators, which aims to know the methodology applied, analyze the results obtained and establish considerations that must be taken into account in the design of the insulators. The problem to be measured was the seismic performance in a three-level health center with or without insulators, with the types of insulators to be considered three types: highdamping insulators (HDR), lead-core insulators (LRB) and frictional pendulum (FPS). The methodology used was applying the Chilean regulation NCh2745-2003, the same that is an adaptation of the "international code for buildings" (IBC), for its acronym in English "which is based on an American standard for the design of insulators and through the modeling of the structure with a computational program such as SAP 2000. The results obtained were for an uninsulated structure, from the first to the last level it has values of 0.35, 0.34 and 0.29 sec. of fundamental period, for the case with high damping insulators the values of 2.98, 2.97, 2.56 of fundamental period were obtained, for insulators with lead core the values were 2.76, 2.75 and 2.38 and for insulators with frictional pendulum system the values were 1.24, 1.22 and 1.06 respectively. When comparing the seismic performance of a structure it is better with insulators, in comparison with a structure without insulators, being the insulators of high damping of better seismic performanceEl presente trabajo trata sobre el desempeño sísmico de un edificio (centro de salud) de tres niveles con o sin aisladores, el cual tiene como objetivos conocer la metodología aplicada, analizar los resultados obtenidos y establecer consideraciones que se deben tener en cuenta en el diseño de los aisladores. El problema a medir fue el desempeño sísmico en un centro de salud de tres niveles con o sin aisladores, siendo los tipos de aisladores a considerar tres tipos: aisladores de alto amortiguamiento (HDR), aisladores con núcleo de plomo (LRB) y sistema de péndulo friccional (FPS). La metodología utilizada fue aplicando la normatividad chilena NCh2745-2003, el mismo que es una adaptación del “código internacional para edificios” (IBC), por sus siglas en ingles que se basa en una norma americana para el diseño de aisladores y a través del modelado de la estructura con una programa computacional como es el SAP 2000.Los resultados obtenidos fueron para una estructura sin aislación. Del primer al último nivel se tiene valores de 0.35, 0.34 y 0.29 seg. de periodo fundamental, para el caso con aisladores de alto amortiguamiento se obtuvieron los valores de 2.98, 2.97, 2.56 de periodo fundamental, para aisladores con núcleo de plomo los valores fueron de 2.76, 2.75 y 2.38 y para aisladores con sistema de péndulo friccional los valores eran 1.24, 1.22 y 1.06 respectivamente. Al comparar el desempeño sísmico de una estructura es mejor con aisladores, en comparación con una estructura sin aisladores, siendo los aisladores de alto amortiguamiento de mejor desempeño sísmicoUniversidad Privada de Tacna2020-04-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/18510.47796/ves.v6i2.185REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 No. 2 (2017): Veritas et Scientia; pp. 747 - 752REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 Núm. 2 (2017): Veritas et Scientia; pp. 747 - 7522617-06392307-513910.47796/ves.v6i2reponame:Revistas - Universidad Privada de Tacnainstname:Universidad Privada de Tacnainstacron:UPTspahttps://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185/169info:eu-repo/semantics/openAccessoai:revistas.upt.edu.pe:article/1852021-07-12T18:02:03Z |
dc.title.none.fl_str_mv |
Seismic performance of a three-level health center with or without insulators Desempeño sísmico de un centro de salud de tres niveles con o sin aisladores |
title |
Seismic performance of a three-level health center with or without insulators |
spellingShingle |
Seismic performance of a three-level health center with or without insulators Arcaya Pancca, Pablo Cesar Aisladores edificio Insulators building |
title_short |
Seismic performance of a three-level health center with or without insulators |
title_full |
Seismic performance of a three-level health center with or without insulators |
title_fullStr |
Seismic performance of a three-level health center with or without insulators |
title_full_unstemmed |
Seismic performance of a three-level health center with or without insulators |
title_sort |
Seismic performance of a three-level health center with or without insulators |
dc.creator.none.fl_str_mv |
Arcaya Pancca, Pablo Cesar |
author |
Arcaya Pancca, Pablo Cesar |
author_facet |
Arcaya Pancca, Pablo Cesar |
author_role |
author |
dc.subject.none.fl_str_mv |
Aisladores edificio Insulators building |
topic |
Aisladores edificio Insulators building |
description |
The present work deals with the seismic performance of a building (health center) of three levels with or without insulators, which aims to know the methodology applied, analyze the results obtained and establish considerations that must be taken into account in the design of the insulators. The problem to be measured was the seismic performance in a three-level health center with or without insulators, with the types of insulators to be considered three types: highdamping insulators (HDR), lead-core insulators (LRB) and frictional pendulum (FPS). The methodology used was applying the Chilean regulation NCh2745-2003, the same that is an adaptation of the "international code for buildings" (IBC), for its acronym in English "which is based on an American standard for the design of insulators and through the modeling of the structure with a computational program such as SAP 2000. The results obtained were for an uninsulated structure, from the first to the last level it has values of 0.35, 0.34 and 0.29 sec. of fundamental period, for the case with high damping insulators the values of 2.98, 2.97, 2.56 of fundamental period were obtained, for insulators with lead core the values were 2.76, 2.75 and 2.38 and for insulators with frictional pendulum system the values were 1.24, 1.22 and 1.06 respectively. When comparing the seismic performance of a structure it is better with insulators, in comparison with a structure without insulators, being the insulators of high damping of better seismic performance |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-04-29 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185 10.47796/ves.v6i2.185 |
url |
https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185 |
identifier_str_mv |
10.47796/ves.v6i2.185 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/185/169 |
dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Privada de Tacna |
publisher.none.fl_str_mv |
Universidad Privada de Tacna |
dc.source.none.fl_str_mv |
REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 No. 2 (2017): Veritas et Scientia; pp. 747 - 752 REVISTA VERITAS ET SCIENTIA - UPT; Vol. 6 Núm. 2 (2017): Veritas et Scientia; pp. 747 - 752 2617-0639 2307-5139 10.47796/ves.v6i2 reponame:Revistas - Universidad Privada de Tacna instname:Universidad Privada de Tacna instacron:UPT |
instname_str |
Universidad Privada de Tacna |
instacron_str |
UPT |
institution |
UPT |
reponame_str |
Revistas - Universidad Privada de Tacna |
collection |
Revistas - Universidad Privada de Tacna |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1842353616959045632 |
score |
12.659675 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).