Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”.
Descripción del Articulo
In order to investigate the seismic behavior of the concrete Diagrid structures, 03 models of 06-level buildings are proposed with a typical 30 m x 37.5 m plant located in an area of high seismicity in Peru. A comparative analysis has been made between two structural systems on the one hand the conv...
| Autor: | |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2019 |
| Institución: | Universidad Privada de Tacna |
| Repositorio: | Revistas - Universidad Privada de Tacna |
| Lenguaje: | español |
| OAI Identifier: | oai:revistas.upt.edu.pe:article/74 |
| Enlace del recurso: | https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/74 |
| Nivel de acceso: | acceso abierto |
| Materia: | Diagrid Sistema Convencional Zona de Alta Sismicidad Coeficiente Básico de Reducción de la Fuerza Sísmica Conventional System Zone of High Sismicity Basic Coefficiente of Reduction of Sismic Force |
| id |
REVUPT_49e8cc62a0dab6d4f5a42395b60890cb |
|---|---|
| oai_identifier_str |
oai:revistas.upt.edu.pe:article/74 |
| network_acronym_str |
REVUPT |
| network_name_str |
Revistas - Universidad Privada de Tacna |
| repository_id_str |
|
| dc.title.none.fl_str_mv |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. Análisis comparativo de edificios con sistemas estructurales de concreto armado: “Duales versus Diagrid”. |
| title |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. |
| spellingShingle |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. Núñez Herrera, José Luis Diagrid Sistema Convencional Zona de Alta Sismicidad Coeficiente Básico de Reducción de la Fuerza Sísmica Diagrid Conventional System Zone of High Sismicity Basic Coefficiente of Reduction of Sismic Force |
| title_short |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. |
| title_full |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. |
| title_fullStr |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. |
| title_full_unstemmed |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. |
| title_sort |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”. |
| dc.creator.none.fl_str_mv |
Núñez Herrera, José Luis |
| author |
Núñez Herrera, José Luis |
| author_facet |
Núñez Herrera, José Luis |
| author_role |
author |
| dc.subject.none.fl_str_mv |
Diagrid Sistema Convencional Zona de Alta Sismicidad Coeficiente Básico de Reducción de la Fuerza Sísmica Diagrid Conventional System Zone of High Sismicity Basic Coefficiente of Reduction of Sismic Force |
| topic |
Diagrid Sistema Convencional Zona de Alta Sismicidad Coeficiente Básico de Reducción de la Fuerza Sísmica Diagrid Conventional System Zone of High Sismicity Basic Coefficiente of Reduction of Sismic Force |
| description |
In order to investigate the seismic behavior of the concrete Diagrid structures, 03 models of 06-level buildings are proposed with a typical 30 m x 37.5 m plant located in an area of high seismicity in Peru. A comparative analysis has been made between two structural systems on the one hand the conventional or orthogonal system and on the other the Diagrid system of reinforced concrete, for the latter two types or models that we will call type A and type B, whose modulation will be analyzed, will be analyzed. every 02 and 04 floors respectively. The three models will have the same characteristics; roofed area, dimensions in plan and elevation, construction materials and loading loads, geographical location, soil type, use and importance, Basic Coefficient of Reduction of the Seismic Force (Ro), these characteristics generate the factors that are regulated by E.030.2016 that defines the procedure for seismic analysis. In this research it has been shown that of the buildings studied (03 models) those with the structural Diagrid system of reinforced concrete (Diagrid type A and Diagrid type B) are more efficient than the conventional system (frames with structural walls), weight of the structure results in lower costs and lower demands of foundation structures of the three models, the lightest is the Diagrid type B system, both Diagrid systems are 30% lighter than the conventional system, the amount of steel needed to the diagonals of the Diagrid type A systems is 29% less than the longitudinal steel required for the structural walls of the conventional system, while Diagrid type B, requires 40% less than the conventional system. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019-01-03 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/74 10.47796/ves.v7i2.74 |
| url |
https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/74 |
| identifier_str_mv |
10.47796/ves.v7i2.74 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/74/67 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Privada de Tacna |
| publisher.none.fl_str_mv |
Universidad Privada de Tacna |
| dc.source.none.fl_str_mv |
REVISTA VERITAS ET SCIENTIA - UPT; Vol. 7 No. 2 (2018): Veritas Et Scientia; pp. 970 - 979 REVISTA VERITAS ET SCIENTIA - UPT; Vol. 7 Núm. 2 (2018): Veritas Et Scientia; pp. 970 - 979 2617-0639 2307-5139 10.47796/ves.v7i2 reponame:Revistas - Universidad Privada de Tacna instname:Universidad Privada de Tacna instacron:UPT |
| instname_str |
Universidad Privada de Tacna |
| instacron_str |
UPT |
| institution |
UPT |
| reponame_str |
Revistas - Universidad Privada de Tacna |
| collection |
Revistas - Universidad Privada de Tacna |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1846791864725798912 |
| spelling |
Comparative analysis of buildings with armed concrete structural systems: “Duales versus Diagrid”.Análisis comparativo de edificios con sistemas estructurales de concreto armado: “Duales versus Diagrid”.Núñez Herrera, José LuisDiagridSistema ConvencionalZona de Alta SismicidadCoeficiente Básico de Reducción de la Fuerza SísmicaDiagridConventional SystemZone of High SismicityBasic Coefficiente of Reduction of Sismic ForceIn order to investigate the seismic behavior of the concrete Diagrid structures, 03 models of 06-level buildings are proposed with a typical 30 m x 37.5 m plant located in an area of high seismicity in Peru. A comparative analysis has been made between two structural systems on the one hand the conventional or orthogonal system and on the other the Diagrid system of reinforced concrete, for the latter two types or models that we will call type A and type B, whose modulation will be analyzed, will be analyzed. every 02 and 04 floors respectively. The three models will have the same characteristics; roofed area, dimensions in plan and elevation, construction materials and loading loads, geographical location, soil type, use and importance, Basic Coefficient of Reduction of the Seismic Force (Ro), these characteristics generate the factors that are regulated by E.030.2016 that defines the procedure for seismic analysis. In this research it has been shown that of the buildings studied (03 models) those with the structural Diagrid system of reinforced concrete (Diagrid type A and Diagrid type B) are more efficient than the conventional system (frames with structural walls), weight of the structure results in lower costs and lower demands of foundation structures of the three models, the lightest is the Diagrid type B system, both Diagrid systems are 30% lighter than the conventional system, the amount of steel needed to the diagonals of the Diagrid type A systems is 29% less than the longitudinal steel required for the structural walls of the conventional system, while Diagrid type B, requires 40% less than the conventional system.Con la finalidad de investigar el comportamiento sísmico, de las estructuras Diagrid de concreto, se plantea 03 modelos de edificios de 06 niveles con una planta típica de 30 m x 37.5m ubicado en una zona de alta sismicidad en el Perú. Se ha realizado un análisis comparativo entre dos sistemas estructurales por un lado el Sistema Convencional u ortogonal y por el otro el sistema de Diagrid de Concreto armado, para este último se analizarán dos tipologías o modelos que denominaremos tipo A y tipo B, cuya modulación será cada 02 y 04 pisos respectivamente. Los tres modelos tendrán las mismas características; área techada, dimensiones en planta y elevación, materiales de construcción y solicitaciones de cargas, de ubicación geográfica, tipo de suelo, uso e importancia, Coeficiente Básico de Reducción de la Fuerza Sísmica (Ro), estas características generan los factores que están normados por la E.030.2016 que define el procedimiento para el análisis sísmico. En esta Investigación se ha demostrado que de los Edificios estudiado (03 modelos) los que son con el Sistema estructural Diagrid de concreto armado (Diagrid tipo A y Diagrid tipo B) son más eficientes que el Sistema convencional (pórticos con muros estructurales). El peso de la estructura redunda en menores costos y menores demandas de estructuras de cimentación de los tres modelos. El más liviano es el Sistema Diagrid tipo B. Ambos sistemas Diagrid son el 30% más livianos que el sistema convencional. La cantidad de acero necesaria para las diagonales de los sistemas Diagrid tipo A es 29% menos que el acero longitudinal necesarios para los muros estructurales del sistema convencional, mientras que Diagrid tipo B, requiere 40% menos que el sistema convencional.Universidad Privada de Tacna2019-01-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/7410.47796/ves.v7i2.74REVISTA VERITAS ET SCIENTIA - UPT; Vol. 7 No. 2 (2018): Veritas Et Scientia; pp. 970 - 979REVISTA VERITAS ET SCIENTIA - UPT; Vol. 7 Núm. 2 (2018): Veritas Et Scientia; pp. 970 - 9792617-06392307-513910.47796/ves.v7i2reponame:Revistas - Universidad Privada de Tacnainstname:Universidad Privada de Tacnainstacron:UPTspahttps://revistas.upt.edu.pe/ojs/index.php/vestsc/article/view/74/67info:eu-repo/semantics/openAccessoai:revistas.upt.edu.pe:article/742021-07-12T18:02:36Z |
| score |
13.057984 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).