Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016

Descripción del Articulo

Objective: To determine preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen. Materials and Methods: Prospective observational study of longitudinal cut, the population was comprised of the patients that entered...

Descripción completa

Detalles Bibliográficos
Autores: Medina Laura, Gladys, Gutiérrez Crespo, Hugo, Zamudio Eslava, Luisa A.
Formato: artículo
Fecha de Publicación:2018
Institución:Universidad Peruana Unión
Repositorio:Revistas - Universidad Peruana Unión
Lenguaje:español
OAI Identifier:oai:ojs2.revistas.upeu.edu.pe:article/1056
Enlace del recurso:https://revistas.upeu.edu.pe/index.php/rc_salud/article/view/1056
Nivel de acceso:acceso abierto
Materia:Preventive measures
pneumonia
mechanical ventilation
Medidas preventivas
neumonía
ventilación mecánica.
id REVUPEU_47564e3a17f7daf153439c1a67b6ed36
oai_identifier_str oai:ojs2.revistas.upeu.edu.pe:article/1056
network_acronym_str REVUPEU
network_name_str Revistas - Universidad Peruana Unión
repository_id_str .
spelling Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016Cumplimiento de las medidas preventivas en pacientes con ventilación mecánica en la Unidad de Cuidados Críticos del Hospital Guillermo Almenara Irigoyen, 2016Medina Laura, GladysGutiérrez Crespo, HugoZamudio Eslava, Luisa A.Preventive measurespneumoniamechanical ventilationMedidas preventivasneumoníaventilación mecánica.Objective: To determine preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen. Materials and Methods: Prospective observational study of longitudinal cut, the population was comprised of the patients that entered the Critical Care Unit. For convenience, a non-probabilistic sample was used, which was comprised of 50 patients who were studied during the months of June to November of 2016. Patients who passed away within 48 hours of admission were excluded. The instrument used was a verification list made up of a set of six preventive measures containing dichotomous type answers, with a reliability of 0.80 using the Richarson Kuder method. Results: 52% of the patients who average ≥ 60 years old, with a male predominance, the respiratory pathology constituted 60% of the cases, 58% of the patients had between 10 and 19 days of use of mechanical ventilation and 78% of the did not show pneumonia. The adequate handling of the airway, hand hygiene during the handling of the airways and head bedside elevation, showed 73.6% of compliance, while the evaluation and records of the necessity of sedoanalgesia showed 70.9% of compliance. Conclusions: in 54% of the studied patients the preventive measures were achieved.Objetivo: Determinar el cumplimiento de las medidas preventivas en pacientes con ventilación mecánica en la Unidad de Cuidados Críticos del Hospital Guillermo Almenara Irigoyen. Material y Métodos: Estudio observacional, prospectivo y de corte longitudinal. La población estuvo conformada por los pacientes que ingresaron a la Unidad de Cuidados Críticos. Se utilizó una muestra no probabilística por conveniencia, conformada por 50 pacientes que fueron estudiados durante los meses de junio a noviembre del año 2016; fueron excluidos los pacientes que fallecieron en las primeras 48 horas de su ingreso. El instrumento utilizado fue una lista de verificación constituida por un conjunto de seis medidas preventivas con respuestas de tipo dicotómica, con una confiabilidad de 0.80, mediante el método de Kuder Richarson. Resultados: El 52% de los pacientes tenía una edad ≥ 60 años, con predominio del sexo masculino. La patología respiratoria se representó en el 60% de los casos, el 58% de los pacientes tuvieron entre 10 y 19 días de uso de ventilación mecánica y el 78% no presentó  neumonía. El manejo adecuado de la vía área, la higiene de manos durante el manejo de la vía aérea y la elevación de la cabecera, presentaron 73.6% de cumplimiento, mientras que la valoración y registro de la necesidad de sedoanalgesia, presentó 70.9% de cumplimiento. Conclusiones: En el 54% de los pacientes estudiados se cumplieron las medidas preventivas.Universidad Peruana Unión2018-06-04info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo revisado por paresapplication/pdftext/htmlhttps://revistas.upeu.edu.pe/index.php/rc_salud/article/view/105610.17162/rccs.v11i1.1056Revista Científica de Ciencias de la Salud; Vol. 11 No. 1 (2018): Revista Científica de Ciencias de la SaludRevista Científica de Ciencias de la Salud; Vol. 11 Núm. 1 (2018): Revista Científica de Ciencias de la Salud2411-00942306-060310.17162/rccs.v11i1reponame:Revistas - Universidad Peruana Unióninstname:Universidad Peruana Unióninstacron:UPEUspahttps://revistas.upeu.edu.pe/index.php/rc_salud/article/view/1056/pdfhttps://revistas.upeu.edu.pe/index.php/rc_salud/article/view/1056/htmlinfo:eu-repo/semantics/openAccessoai:ojs2.revistas.upeu.edu.pe:article/10562021-06-22T19:13:13Z
dc.title.none.fl_str_mv Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
Cumplimiento de las medidas preventivas en pacientes con ventilación mecánica en la Unidad de Cuidados Críticos del Hospital Guillermo Almenara Irigoyen, 2016
title Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
spellingShingle Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
Medina Laura, Gladys
Preventive measures
pneumonia
mechanical ventilation
Medidas preventivas
neumonía
ventilación mecánica.
title_short Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_full Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_fullStr Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_full_unstemmed Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
title_sort Preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen, 2016
dc.creator.none.fl_str_mv Medina Laura, Gladys
Gutiérrez Crespo, Hugo
Zamudio Eslava, Luisa A.
author Medina Laura, Gladys
author_facet Medina Laura, Gladys
Gutiérrez Crespo, Hugo
Zamudio Eslava, Luisa A.
author_role author
author2 Gutiérrez Crespo, Hugo
Zamudio Eslava, Luisa A.
author2_role author
author
dc.subject.none.fl_str_mv Preventive measures
pneumonia
mechanical ventilation
Medidas preventivas
neumonía
ventilación mecánica.
topic Preventive measures
pneumonia
mechanical ventilation
Medidas preventivas
neumonía
ventilación mecánica.
description Objective: To determine preventive measures compliance on patients with mechanical ventilation in the Critical Care Unit at the Hospital Guillermo Almenara Irigoyen. Materials and Methods: Prospective observational study of longitudinal cut, the population was comprised of the patients that entered the Critical Care Unit. For convenience, a non-probabilistic sample was used, which was comprised of 50 patients who were studied during the months of June to November of 2016. Patients who passed away within 48 hours of admission were excluded. The instrument used was a verification list made up of a set of six preventive measures containing dichotomous type answers, with a reliability of 0.80 using the Richarson Kuder method. Results: 52% of the patients who average ≥ 60 years old, with a male predominance, the respiratory pathology constituted 60% of the cases, 58% of the patients had between 10 and 19 days of use of mechanical ventilation and 78% of the did not show pneumonia. The adequate handling of the airway, hand hygiene during the handling of the airways and head bedside elevation, showed 73.6% of compliance, while the evaluation and records of the necessity of sedoanalgesia showed 70.9% of compliance. Conclusions: in 54% of the studied patients the preventive measures were achieved.
publishDate 2018
dc.date.none.fl_str_mv 2018-06-04
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artículo revisado por pares
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.upeu.edu.pe/index.php/rc_salud/article/view/1056
10.17162/rccs.v11i1.1056
url https://revistas.upeu.edu.pe/index.php/rc_salud/article/view/1056
identifier_str_mv 10.17162/rccs.v11i1.1056
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.upeu.edu.pe/index.php/rc_salud/article/view/1056/pdf
https://revistas.upeu.edu.pe/index.php/rc_salud/article/view/1056/html
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
text/html
dc.publisher.none.fl_str_mv Universidad Peruana Unión
publisher.none.fl_str_mv Universidad Peruana Unión
dc.source.none.fl_str_mv Revista Científica de Ciencias de la Salud; Vol. 11 No. 1 (2018): Revista Científica de Ciencias de la Salud
Revista Científica de Ciencias de la Salud; Vol. 11 Núm. 1 (2018): Revista Científica de Ciencias de la Salud
2411-0094
2306-0603
10.17162/rccs.v11i1
reponame:Revistas - Universidad Peruana Unión
instname:Universidad Peruana Unión
instacron:UPEU
instname_str Universidad Peruana Unión
instacron_str UPEU
institution UPEU
reponame_str Revistas - Universidad Peruana Unión
collection Revistas - Universidad Peruana Unión
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1796961640327938048
score 13.919782
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).