Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina
Descripción del Articulo
Universal adhesives and their versatility with adhesive techniques generate a controversy between the use and non-use of etching acid before the application of the universal adhesive. Objective: To find the optimal acid etching time prior to the application of Clearfil Universal Bond on bovine tooth...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2021 |
Institución: | Universidad Peruana Cayetano Heredia |
Repositorio: | Revistas - Universidad Peruana Cayetano Heredia |
Lenguaje: | español |
OAI Identifier: | oai:revistas.upch.edu.pe:article/3969 |
Enlace del recurso: | https://revistas.upch.edu.pe/index.php/REH/article/view/3969 |
Nivel de acceso: | acceso abierto |
id |
REVUPCH_39f549d0c868de230dda3b3337c6c1b1 |
---|---|
oai_identifier_str |
oai:revistas.upch.edu.pe:article/3969 |
network_acronym_str |
REVUPCH |
network_name_str |
Revistas - Universidad Peruana Cayetano Heredia |
repository_id_str |
|
spelling |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentinaEstudio sobre los diferentes tiempos de acondicionamiento previo al sistema adhesivo universal en dentina de dientes de bovinoSaravia Rojas, Miguel AngelBernal Ponce, Allison RuthUniversal adhesives and their versatility with adhesive techniques generate a controversy between the use and non-use of etching acid before the application of the universal adhesive. Objective: To find the optimal acid etching time prior to the application of Clearfil Universal Bond on bovine tooth dentin, by analyzing the values of resistance to microtraction. Material and methods: Experimental, prospective and comparative study. 6 bovine upper central incisors were used, from which 80 specimens were obtained and divided into 4 groups of 20 specimens each. After complying with the parameters of each group, the specimens were subjected to the microtraction test. Results: The group of acid etching for 10 seconds showed a higher resistance to microtraction with a minimum resistance of 10.43 MPa and a maximum resistance of 31.45 MPa, showing an average resistance of microtraction of 20.78±6.36 MPa. Conclusion: The adhesive resistance to microtraction in bovine dentin under the etching and rinsing mode for 10 seconds prior to the Clearfil Universal Bond universal adhesive system was higher compared to the group treated only with the universal adhesive system, in addition to proving that a reduced exposure time of phosphoric acid in dentin is ideal to avoid deterioration of the dentin surface, considering its morphology.Los adhesivos universales y su versatilidad con las técnicas adhesivas desatan una controversia entre el uso y no uso de ácido grabador antes de la aplicación del adhesivo universal. Objetivo: Encontrar el tiempo óptimo de grabado ácido previo a la aplicación del Clearfil Universal Bond sobre la dentina de diente de bovino, mediante el análisis de los valores de resistencia a la microtracción. Material y métodos: Estudio experimental, prospectivo y comparativo. Se utilizaron 6 incisivos centrales superiores de bovino, de los que se obtuvieron 80 especímenes separados en 4 grupos de 20 especímenes cada uno. Luego de cumplir con los parámetros de cada grupo, se sometió a los especímenes a la prueba de microtracción. Resultados: El grupo de grabado ácido previo por 10 segundos mostró una mayor resistencia a la microtracción con una resistencia mínima de 10,43 MPa y una resistencia máxima de 31,45 MPa, mostrando una resistencia media de microtracción de 20,78±6,36 MPa. Conclusiones: La resistencia adhesiva a la microtracción en dentina de bovino bajo el modo grabado y enjuague por 10 segundos previo al sistema adhesivo universal Clearfil Universal Bond fue mayor en comparación al grupo tratado solo con el sistema adhesivo universal, además de probar que la exposición por un tiempo reducido de ácido fosfórico en dentina es idóneo para evitar el deterioro de la superficie dentinaria, considerando su morfología.Universidad Peruana Cayetano Heredia2021-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.upch.edu.pe/index.php/REH/article/view/396910.20453/reh.v31i2.3969Revista Estomatológica Herediana; Vol. 31 No. 2 (2021): April-June; 90-102Revista Estomatológica Herediana; Vol. 31 Núm. 2 (2021): Abril-Junio; 90-102Revista Estomatológica Herediana; v. 31 n. 2 (2021): Abril-Junio; 90-1022225-76161019-4355reponame:Revistas - Universidad Peruana Cayetano Herediainstname:Universidad Peruana Cayetano Herediainstacron:UPCHspahttps://revistas.upch.edu.pe/index.php/REH/article/view/3969/4523Derechos de autor 2021 Miguel Angel Saravia Rojas, Allison Ruth Bernal Ponceinfo:eu-repo/semantics/openAccessoai:revistas.upch.edu.pe:article/39692021-07-01T21:35:02Z |
dc.title.none.fl_str_mv |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina Estudio sobre los diferentes tiempos de acondicionamiento previo al sistema adhesivo universal en dentina de dientes de bovino |
title |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina |
spellingShingle |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina Saravia Rojas, Miguel Angel |
title_short |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina |
title_full |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina |
title_fullStr |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina |
title_full_unstemmed |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina |
title_sort |
Comparative study in vitro on the different times of conventional acid etching system before bonding with an universal adhesive on bovine dentina |
dc.creator.none.fl_str_mv |
Saravia Rojas, Miguel Angel Bernal Ponce, Allison Ruth |
author |
Saravia Rojas, Miguel Angel |
author_facet |
Saravia Rojas, Miguel Angel Bernal Ponce, Allison Ruth |
author_role |
author |
author2 |
Bernal Ponce, Allison Ruth |
author2_role |
author |
description |
Universal adhesives and their versatility with adhesive techniques generate a controversy between the use and non-use of etching acid before the application of the universal adhesive. Objective: To find the optimal acid etching time prior to the application of Clearfil Universal Bond on bovine tooth dentin, by analyzing the values of resistance to microtraction. Material and methods: Experimental, prospective and comparative study. 6 bovine upper central incisors were used, from which 80 specimens were obtained and divided into 4 groups of 20 specimens each. After complying with the parameters of each group, the specimens were subjected to the microtraction test. Results: The group of acid etching for 10 seconds showed a higher resistance to microtraction with a minimum resistance of 10.43 MPa and a maximum resistance of 31.45 MPa, showing an average resistance of microtraction of 20.78±6.36 MPa. Conclusion: The adhesive resistance to microtraction in bovine dentin under the etching and rinsing mode for 10 seconds prior to the Clearfil Universal Bond universal adhesive system was higher compared to the group treated only with the universal adhesive system, in addition to proving that a reduced exposure time of phosphoric acid in dentin is ideal to avoid deterioration of the dentin surface, considering its morphology. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-07-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.upch.edu.pe/index.php/REH/article/view/3969 10.20453/reh.v31i2.3969 |
url |
https://revistas.upch.edu.pe/index.php/REH/article/view/3969 |
identifier_str_mv |
10.20453/reh.v31i2.3969 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.upch.edu.pe/index.php/REH/article/view/3969/4523 |
dc.rights.none.fl_str_mv |
Derechos de autor 2021 Miguel Angel Saravia Rojas, Allison Ruth Bernal Ponce info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2021 Miguel Angel Saravia Rojas, Allison Ruth Bernal Ponce |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Peruana Cayetano Heredia |
publisher.none.fl_str_mv |
Universidad Peruana Cayetano Heredia |
dc.source.none.fl_str_mv |
Revista Estomatológica Herediana; Vol. 31 No. 2 (2021): April-June; 90-102 Revista Estomatológica Herediana; Vol. 31 Núm. 2 (2021): Abril-Junio; 90-102 Revista Estomatológica Herediana; v. 31 n. 2 (2021): Abril-Junio; 90-102 2225-7616 1019-4355 reponame:Revistas - Universidad Peruana Cayetano Heredia instname:Universidad Peruana Cayetano Heredia instacron:UPCH |
instname_str |
Universidad Peruana Cayetano Heredia |
instacron_str |
UPCH |
institution |
UPCH |
reponame_str |
Revistas - Universidad Peruana Cayetano Heredia |
collection |
Revistas - Universidad Peruana Cayetano Heredia |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1846152835573481472 |
score |
12.796332 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).