Effect of charge loading during electrocoagulation in dairy wastewater

Descripción del Articulo

Electrocoagulation is frequently studied considering only the current or current density as a determining parameter when looking for the optimal conditions of wastewater treatment; however, these are correlated to the charge loading parameter that regulates the dose of metal to be dissolved. Due to...

Descripción completa

Detalles Bibliográficos
Autores: Cachay Melly, Jaime Alberto, Quipuzco Ushñahua, Lawrence Enrique
Formato: artículo
Fecha de Publicación:2022
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/24247
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/24247
Nivel de acceso:acceso abierto
Materia:charge loading
dairy industry
electrocoagulation
turbidity removal
wastewater
aguas residuales
electrocoagulación
flujo de carga
industria láctea
remoción de turbidez
id REVUNMSM_e0b7f88bf27cb7a2146664974b4c614e
oai_identifier_str oai:ojs.csi.unmsm:article/24247
network_acronym_str REVUNMSM
network_name_str Revistas - Universidad Nacional Mayor de San Marcos
repository_id_str
spelling Effect of charge loading during electrocoagulation in dairy wastewaterEfecto del flujo de carga durante el tratamiento por electrocoagulación en aguas residuales lácteasCachay Melly, Jaime AlbertoQuipuzco Ushñahua, Lawrence EnriqueCachay Melly, Jaime AlbertoQuipuzco Ushñahua, Lawrence Enriquecharge loadingdairy industryelectrocoagulationturbidity removalwastewateraguas residualeselectrocoagulaciónflujo de cargaindustria láctearemoción de turbidezElectrocoagulation is frequently studied considering only the current or current density as a determining parameter when looking for the optimal conditions of wastewater treatment; however, these are correlated to the charge loading parameter that regulates the dose of metal to be dissolved. Due to this, the present study incorporates the charge loading to find the optimal conditions of treatment by electrocoagulation to the effluents of a dairy industry, “La Planta Piloto de Leche” of Universidad Nacional Agraria La Molina, taking as a variable response to the removal of turbidity. Work has been done in batch on prototypes of 2.2 liters of effective capacity. The aluminum and iron electrodes, acting as anode and cathode respectively, were the best materials for the treatment, in addition, the highest turbidity removal was achieved at a pH of 8 and a charge flow of 5.65 F/m3, achieved at 2 Ampere (2A) of supplied current and 10 minutes of treatment. Subsequently, the test under a constant load flow (5.65 F/m3) reaffirmed that at 2A and 10 minutes of electrochemical treatment, the highest removals of contaminants, mainly oils and greases, and turbidity are achieved.Con frecuencia se estudia la electrocoagulación considerando la intensidad de corriente o densidad de corriente como un parámetro determinante al buscar las condiciones óptimas de tratamiento de aguas residuales; sin embargo, estos se encuentran correlacionados al parámetro flujo de carga (Charge loading) que regula la dosis del metal que se disolverá. Debido a ello, el presente estudio incorpora al flujo de carga para encontrar las condiciones óptimas de tratamiento mediante electrocoagulación a los efluentes de una industria láctea, la planta piloto de leche de la Universidad Nacional Agraria La Molina, tomando como variable respuesta a la remoción de la turbidez. Se ha trabajado en batch en prototipos de 2.2 litros de capacidad efectiva. Los electrodos de aluminio y hierro, actuando como ánodo y cátodo respectivamente, fueron los mejores materiales para el tratamiento, además se alcanzó la mayor remoción de turbidez a un pH de 8 y un flujo de carga de 5.65 F/m3, logrado a 2 Amperios (2A) de corriente suministrada y 10 minutos de tratamiento. Posteriormente, la prueba bajo un flujo de carga constante (5.65 F/m3) reafirmó que a 2A y 10 minutos de tratamiento electroquímico se logra las mayores remociones de contaminantes, principalmente aceites y grasas y, turbidez.Universidad Nacional Mayor de San Marcos, Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica2022-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/2424710.15381/iigeo.v25i50.24247Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 25 No. 50 (2022); 257-264Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 25 Núm. 50 (2022); 257-2641682-30871561-0888reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/24247/19178Derechos de autor 2022 Jaime Alberto Cachay Melly, Lawrence Enrique Quipuzco Ushñahuahttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/242472023-01-25T13:36:28Z
dc.title.none.fl_str_mv Effect of charge loading during electrocoagulation in dairy wastewater
Efecto del flujo de carga durante el tratamiento por electrocoagulación en aguas residuales lácteas
title Effect of charge loading during electrocoagulation in dairy wastewater
spellingShingle Effect of charge loading during electrocoagulation in dairy wastewater
Cachay Melly, Jaime Alberto
charge loading
dairy industry
electrocoagulation
turbidity removal
wastewater
aguas residuales
electrocoagulación
flujo de carga
industria láctea
remoción de turbidez
title_short Effect of charge loading during electrocoagulation in dairy wastewater
title_full Effect of charge loading during electrocoagulation in dairy wastewater
title_fullStr Effect of charge loading during electrocoagulation in dairy wastewater
title_full_unstemmed Effect of charge loading during electrocoagulation in dairy wastewater
title_sort Effect of charge loading during electrocoagulation in dairy wastewater
dc.creator.none.fl_str_mv Cachay Melly, Jaime Alberto
Quipuzco Ushñahua, Lawrence Enrique
Cachay Melly, Jaime Alberto
Quipuzco Ushñahua, Lawrence Enrique
author Cachay Melly, Jaime Alberto
author_facet Cachay Melly, Jaime Alberto
Quipuzco Ushñahua, Lawrence Enrique
author_role author
author2 Quipuzco Ushñahua, Lawrence Enrique
author2_role author
dc.subject.none.fl_str_mv charge loading
dairy industry
electrocoagulation
turbidity removal
wastewater
aguas residuales
electrocoagulación
flujo de carga
industria láctea
remoción de turbidez
topic charge loading
dairy industry
electrocoagulation
turbidity removal
wastewater
aguas residuales
electrocoagulación
flujo de carga
industria láctea
remoción de turbidez
description Electrocoagulation is frequently studied considering only the current or current density as a determining parameter when looking for the optimal conditions of wastewater treatment; however, these are correlated to the charge loading parameter that regulates the dose of metal to be dissolved. Due to this, the present study incorporates the charge loading to find the optimal conditions of treatment by electrocoagulation to the effluents of a dairy industry, “La Planta Piloto de Leche” of Universidad Nacional Agraria La Molina, taking as a variable response to the removal of turbidity. Work has been done in batch on prototypes of 2.2 liters of effective capacity. The aluminum and iron electrodes, acting as anode and cathode respectively, were the best materials for the treatment, in addition, the highest turbidity removal was achieved at a pH of 8 and a charge flow of 5.65 F/m3, achieved at 2 Ampere (2A) of supplied current and 10 minutes of treatment. Subsequently, the test under a constant load flow (5.65 F/m3) reaffirmed that at 2A and 10 minutes of electrochemical treatment, the highest removals of contaminants, mainly oils and greases, and turbidity are achieved.
publishDate 2022
dc.date.none.fl_str_mv 2022-12-31
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/24247
10.15381/iigeo.v25i50.24247
url https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/24247
identifier_str_mv 10.15381/iigeo.v25i50.24247
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/24247/19178
dc.rights.none.fl_str_mv Derechos de autor 2022 Jaime Alberto Cachay Melly, Lawrence Enrique Quipuzco Ushñahua
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2022 Jaime Alberto Cachay Melly, Lawrence Enrique Quipuzco Ushñahua
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica
publisher.none.fl_str_mv Universidad Nacional Mayor de San Marcos, Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica
dc.source.none.fl_str_mv Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 25 No. 50 (2022); 257-264
Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 25 Núm. 50 (2022); 257-264
1682-3087
1561-0888
reponame:Revistas - Universidad Nacional Mayor de San Marcos
instname:Universidad Nacional Mayor de San Marcos
instacron:UNMSM
instname_str Universidad Nacional Mayor de San Marcos
instacron_str UNMSM
institution UNMSM
reponame_str Revistas - Universidad Nacional Mayor de San Marcos
collection Revistas - Universidad Nacional Mayor de San Marcos
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1795238289829003264
score 13.893769
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).