Soil mechanics and resistance study: Lima case
Descripción del Articulo
It is necessary to carry out mechanics and soil resistance studies before deciding to carry out a civil construction with a height greater than 6 meters, in the Lima area, considering that it has a heterogeneous, conglomeradic suleo and is located in an area of seismic risk [10 , 1], for this, a g...
Autor: | |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2012 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/726 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/726 |
Nivel de acceso: | acceso abierto |
Materia: | Geological geotechnical landfill yours clay sand-clay Geológico geotécnico relleno sanitario suyo arcilla arena-arcilloso |
id |
REVUNMSM_df1920421f99dc4f01f74b250e4fb7d1 |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/726 |
network_acronym_str |
REVUNMSM |
network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
repository_id_str |
|
dc.title.none.fl_str_mv |
Soil mechanics and resistance study: Lima case Estudio de mecánica y resistencia de suelos: caso Lima |
title |
Soil mechanics and resistance study: Lima case |
spellingShingle |
Soil mechanics and resistance study: Lima case Gallarday Bocanegra, Tomás Geological geotechnical landfill yours clay sand-clay Geológico geotécnico relleno sanitario suyo arcilla arena-arcilloso |
title_short |
Soil mechanics and resistance study: Lima case |
title_full |
Soil mechanics and resistance study: Lima case |
title_fullStr |
Soil mechanics and resistance study: Lima case |
title_full_unstemmed |
Soil mechanics and resistance study: Lima case |
title_sort |
Soil mechanics and resistance study: Lima case |
dc.creator.none.fl_str_mv |
Gallarday Bocanegra, Tomás |
author |
Gallarday Bocanegra, Tomás |
author_facet |
Gallarday Bocanegra, Tomás |
author_role |
author |
dc.subject.none.fl_str_mv |
Geological geotechnical landfill yours clay sand-clay Geológico geotécnico relleno sanitario suyo arcilla arena-arcilloso |
topic |
Geological geotechnical landfill yours clay sand-clay Geológico geotécnico relleno sanitario suyo arcilla arena-arcilloso |
description |
It is necessary to carry out mechanics and soil resistance studies before deciding to carry out a civil construction with a height greater than 6 meters, in the Lima area, considering that it has a heterogeneous, conglomeradic suleo and is located in an area of seismic risk [10 , 1], for this, a granularity determination will be made, which influences the movement and resistance of the soil, which will support the weight of the superstructure. To obtain its result, it is essential to practice a pit or pit that has width and depth according to the design of the foundation, allowing workers to operate easily. Sporadically when the technical and physical circumstances of the soil allow it, its sampling can be carried out in situ, determining in the field the internal friction angle, which will give the moment of failure for the soil, simulating the pressure exerted by the work, to know this physical data requires the application of Peruvian technical standards, which classify soils for civil engineering purposes, this includes the analysis of the results carried out in prestigious national laboratories, with this information the Data parameter is determined, prior to the application of the terzaghi formula [ 14] that allows conclusions to be drawn that, when applied, avoid unnecessary overload, given by the use of exaggerated material in the foundation of civil works, with a negative impact on costs, taxing the economy of the owners. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-01-28 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/726 10.15381/iigeo.v8i15.726 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/726 |
identifier_str_mv |
10.15381/iigeo.v8i15.726 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/726/577 |
dc.rights.none.fl_str_mv |
Derechos de autor 2012 Tomás Exequiel Gallarday https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2012 Tomás Exequiel Gallarday https://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica |
publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica |
dc.source.none.fl_str_mv |
Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 8 No. 15 (2005); 78-87 Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 8 Núm. 15 (2005); 78-87 1682-3087 1561-0888 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
collection |
Revistas - Universidad Nacional Mayor de San Marcos |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1795238284789547008 |
spelling |
Soil mechanics and resistance study: Lima caseEstudio de mecánica y resistencia de suelos: caso LimaGallarday Bocanegra, TomásGeologicalgeotechnicallandfillyoursclaysand-clayGeológicogeotécnicorelleno sanitariosuyoarcillaarena-arcillosoIt is necessary to carry out mechanics and soil resistance studies before deciding to carry out a civil construction with a height greater than 6 meters, in the Lima area, considering that it has a heterogeneous, conglomeradic suleo and is located in an area of seismic risk [10 , 1], for this, a granularity determination will be made, which influences the movement and resistance of the soil, which will support the weight of the superstructure. To obtain its result, it is essential to practice a pit or pit that has width and depth according to the design of the foundation, allowing workers to operate easily. Sporadically when the technical and physical circumstances of the soil allow it, its sampling can be carried out in situ, determining in the field the internal friction angle, which will give the moment of failure for the soil, simulating the pressure exerted by the work, to know this physical data requires the application of Peruvian technical standards, which classify soils for civil engineering purposes, this includes the analysis of the results carried out in prestigious national laboratories, with this information the Data parameter is determined, prior to the application of the terzaghi formula [ 14] that allows conclusions to be drawn that, when applied, avoid unnecessary overload, given by the use of exaggerated material in the foundation of civil works, with a negative impact on costs, taxing the economy of the owners.Es necesario efectuar estudios de mecánica y resistencia de suelos antes de decidir realizar una construccion civil con altura mayor a 6 metros, en el área de lima, considerando que esta tiene un suleo heterogéneo, conglomerádico y está ubicado en un área de riesgo sísmico[10,1], para ello se efectuará una determinación de granulosidad, que influye en el movimiento y resistencia del suelo, que soportará el peso de la sobreestructura. Para obtener su resultado, es fundamental practicar una calicata o pozo que tenga ancho y profundidad de acuerdo al diseño del cimiento, permita operar con facilidad a los trabajadores. Esporádicamente cuando las circunstancias técnicas y físicas del suelo lo permitan, su muestreo puede realizarse in sito, determinando en campo el ángulo de fricción interna, que dará el momento de falla para el suelo, simulando la presión ejercida por la obra, conocer este dato físico requiere aplicar las normas técnicas peruanas, que clasifican los suelos para própositos de ingeniería civíl, ello incluye el análisis de los resultados efectuados en laboratorios nacionales de prestigio , con esta información se determina el parámetro Dato, previo a la aplicacion de la fórmula de terzaghi[14] que permite obtener conclusiones, que aplicadas evite la sobrecarga innecesaria, dado por el uso de material exagerado en el cimiento de la obra civil, con impacto negativo en los costos, gravando la economía de los titulares.Universidad Nacional Mayor de San Marcos, Facultad de Ingeniería Geológica, Minera, Metalúrgica y Geográfica2012-01-28info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/72610.15381/iigeo.v8i15.726Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 8 No. 15 (2005); 78-87Revista del Instituto de investigación de la Facultad de minas, metalurgia y ciencias geográficas; Vol. 8 Núm. 15 (2005); 78-871682-30871561-0888reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/iigeo/article/view/726/577Derechos de autor 2012 Tomás Exequiel Gallardayhttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/7262020-12-02T12:08:12Z |
score |
13.95948 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).