Calculation of Hypocentral Parameters using the Generalized Inversion Method
Descripción del Articulo
In this research a generalized inversion method was applied to obtain the epicenter of seismic events of local and regional origin from the readings of arrival time of P and S phases of at least 4 seismic stations. The initial condition of the model is obtained from the location of the seismic stati...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2017 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/14708 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/14708 |
Nivel de acceso: | acceso abierto |
Materia: | sismología epicentro inversión seismology epicenter inversion |
id |
REVUNMSM_db1bc474b2704cd77b8091b45ee8723e |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/14708 |
network_acronym_str |
REVUNMSM |
network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
repository_id_str |
|
spelling |
Calculation of Hypocentral Parameters using the Generalized Inversion MethodCálculo de Parámetros Hipocentrales Mediante el Método de Inversión GeneralizadaJiménez, CésarOlcese, DanielsismologíaepicentroinversiónseismologyepicenterinversionIn this research a generalized inversion method was applied to obtain the epicenter of seismic events of local and regional origin from the readings of arrival time of P and S phases of at least 4 seismic stations. The initial condition of the model is obtained from the location of the seismic station closest to the epicenter, the initial origin time is obtained from the Wadati diagram and the initial depth is set up to 33 km for each case. We suppose a homogeneous velocity model of the P wave of 7.6 km/s (obtained from the inversion process). From the analysis of eigenvalues and eigenvectors of the system matrix (GTG), we deduce that the most stable parameter is the origin time and the most unstable parameter is the focal depth. The linearized model converges quickly to the solution.En este trabajo se aplicó el método de inversión generalizada para calcular los parámetros hipocentrales de eventos sísmicos de origen local y regional a partir de la lectura del tiempo de arribo de las fases P y S de al menos 4 estaciones sísmicas. La condición inicial del modelo se obtiene de la posición (x0, y0) de la estación sísmica más cercana al epicentro; a partir del diagrama de Wadati se obtiene el tiempo origen inicial t0 y la profundidad inicial z0 se ja en 33 km para todos los casos. Se asume un modelo de velocidad homogéneo con vp = 7.6 km/s (obtenido a partir del proceso de inversión). Del análisis de los autovalores y autovectores de la matriz del sistema (GTG) se deduce que el parámetro más estable es el tiempo origen y el parámetro más inestable es la profundidad focal. La solución inicial del modelo numérico linealizado converge rápidamente a la solución de menor residual.Universidad Nacional Mayor de San Marcos2017-10-15info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/1470810.15381/rif.v20i1.14708Revista de Investigación de Física; Vol. 20 No. 1 (2017); 1-8Revista de Investigación de Física; Vol. 20 Núm. 1 (2017); 1-81728-29771605-7724reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/14708/12919Derechos de autor 2017 César Jiménez, Daniel Olcesehttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/147082021-08-17T20:26:27Z |
dc.title.none.fl_str_mv |
Calculation of Hypocentral Parameters using the Generalized Inversion Method Cálculo de Parámetros Hipocentrales Mediante el Método de Inversión Generalizada |
title |
Calculation of Hypocentral Parameters using the Generalized Inversion Method |
spellingShingle |
Calculation of Hypocentral Parameters using the Generalized Inversion Method Jiménez, César sismología epicentro inversión seismology epicenter inversion |
title_short |
Calculation of Hypocentral Parameters using the Generalized Inversion Method |
title_full |
Calculation of Hypocentral Parameters using the Generalized Inversion Method |
title_fullStr |
Calculation of Hypocentral Parameters using the Generalized Inversion Method |
title_full_unstemmed |
Calculation of Hypocentral Parameters using the Generalized Inversion Method |
title_sort |
Calculation of Hypocentral Parameters using the Generalized Inversion Method |
dc.creator.none.fl_str_mv |
Jiménez, César Olcese, Daniel |
author |
Jiménez, César |
author_facet |
Jiménez, César Olcese, Daniel |
author_role |
author |
author2 |
Olcese, Daniel |
author2_role |
author |
dc.subject.none.fl_str_mv |
sismología epicentro inversión seismology epicenter inversion |
topic |
sismología epicentro inversión seismology epicenter inversion |
description |
In this research a generalized inversion method was applied to obtain the epicenter of seismic events of local and regional origin from the readings of arrival time of P and S phases of at least 4 seismic stations. The initial condition of the model is obtained from the location of the seismic station closest to the epicenter, the initial origin time is obtained from the Wadati diagram and the initial depth is set up to 33 km for each case. We suppose a homogeneous velocity model of the P wave of 7.6 km/s (obtained from the inversion process). From the analysis of eigenvalues and eigenvectors of the system matrix (GTG), we deduce that the most stable parameter is the origin time and the most unstable parameter is the focal depth. The linearized model converges quickly to the solution. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-10-15 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/14708 10.15381/rif.v20i1.14708 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/14708 |
identifier_str_mv |
10.15381/rif.v20i1.14708 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/fisica/article/view/14708/12919 |
dc.rights.none.fl_str_mv |
Derechos de autor 2017 César Jiménez, Daniel Olcese https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2017 César Jiménez, Daniel Olcese https://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos |
dc.source.none.fl_str_mv |
Revista de Investigación de Física; Vol. 20 No. 1 (2017); 1-8 Revista de Investigación de Física; Vol. 20 Núm. 1 (2017); 1-8 1728-2977 1605-7724 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
collection |
Revistas - Universidad Nacional Mayor de San Marcos |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1795238318980464640 |
score |
13.754616 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).