Dimensional accuracy of a condensation silicone: comparison of storage time and measurement method

Descripción del Articulo

Objective: This study aims to calculate the dimensional change of a condensation silicone through different measuring instruments (digital paquimeter, stereomicroscope and 3D coordinate measuring machine); in four separate times. Methods: In the experimental in vitro study four impressions of conden...

Descripción completa

Detalles Bibliográficos
Autores: Bandoli Monteiro, Jaiane, Cláudio Contreras, Lisseth Patrícia, Damasceno Cunha, Thaiana, Vasconcelos de Castro Leite, Luís Paulo, de Morais Vieira, Jalon, de Oliveira Salgado, Ivone
Formato: artículo
Fecha de Publicación:2018
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/15556
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/15556
Nivel de acceso:acceso abierto
Materia:Dental materials
Dimensional measurement accuracy
Silicone elastomers
Elastómeros de silicona
Materiales dentales
Precisión de la medición dimensional
Descripción
Sumario:Objective: This study aims to calculate the dimensional change of a condensation silicone through different measuring instruments (digital paquimeter, stereomicroscope and 3D coordinate measuring machine); in four separate times. Methods: In the experimental in vitro study four impressions of condensation silicone (Speedex) were performed with a specific device with four-time distances, resulting in sixteen measurements with each instrument. The pre-determinated times for measurement were: immediately after the impression (T0), after 30 min (T1), after 1 h (T2) and after 7 days (T3) of impression. The averages and standard deviations of measurements were submitted to analysis of variance and Tukey’s test, with significance level of 0.05. Results: The average (mm) for the samples measured with a digital paquimeter (T0= 5.82; T1 y T2= 5.80; T3= 5.78) and 3D coordinate measuring machine (T0= 5.75; T1=5.78; T2 y T3 = 5.77), there was a significant difference of dimension for the initial values in relation of values after 7 days (p = 0.037; p = 0.013, respectively), the same did not happen for the use of the stereomicroscope (T0, T1 y T3= 5.83; y T2= 5.81), that presented statistic similarity for all evaluated times (p = 0.754). Conclusions: The measurement method was the relevant factor that influenced the results of the dimensions of the impressions, the four times were not relevant in the dimensional changes of the silicon of condensation analyzed.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).