Evaluation of micro strain in different thicknesses of the buccal bone plate
Descripción del Articulo
For an implant-supported restoration of the maxillary anterior area; the buccal bone plate should have a minimum thickness to ensure an optimal and predictable behavior of soft tissue. Objective: To evaluate the mechanical behavior of stress and microstrain (von Mises yield criterion); in different...
Autores: | , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2018 |
Institución: | Universidad Nacional Mayor de San Marcos |
Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
Lenguaje: | español |
OAI Identifier: | oai:ojs.csi.unmsm:article/15150 |
Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/15150 |
Nivel de acceso: | acceso abierto |
Materia: | Análisis de elementos finitos Hueso cortical Implantes dentales Cortical bone Dental implants Finite element analysis |
id |
REVUNMSM_54cf0d2d522b4ddd7925e34d60b1fe18 |
---|---|
oai_identifier_str |
oai:ojs.csi.unmsm:article/15150 |
network_acronym_str |
REVUNMSM |
network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
repository_id_str |
|
spelling |
Evaluation of micro strain in different thicknesses of the buccal bone plateEvaluación de la microdeformación según diferentes espesores de la tabla ósea vestibularEscobar Restrepo, Julio CesarSerna Ceballos, Juan DavidLatorre Correa, FedericoVillarraga Ossa, Junes AbdulAnálisis de elementos finitosHueso corticalImplantes dentalesCortical boneDental implantsFinite element analysisFor an implant-supported restoration of the maxillary anterior area; the buccal bone plate should have a minimum thickness to ensure an optimal and predictable behavior of soft tissue. Objective: To evaluate the mechanical behavior of stress and microstrain (von Mises yield criterion); in different thicknesses of buccal maxillary bone plates. Methods: The finite element method was used for modeling the maxillary anterior area with three different buccal bone thickness 0.5, 1 and 1.5 mm. An implant-supported restoration was modeled as well, to which a static load of 200 N was applied. Stress and microstrains were obtained in the buccal bone plates at 2, 4 and 6 mm from the alveolar crest towards the apical direction, both in cancellous and cortical bone. Results: Based on the finite element method, it was found that in the thickness of 0.5 mm of buccal bone plate (cortical) with 2 mms height, results showed stress von Mises (31 056 mpa) and displayed microstrains (2 154 µε). As the thickness increased to 1.5 mm with the 2 mm height results stated (22 913 mpa and 1 570 µε). This same trend was observed in the other two heights. Conclusions: The highest values von Mises and micro deformation were found on the crest of the buccal plate with 0.5 mm thickness and decreasing as the volume of cancellous bone increased towards apical direction.La restauración implantosoportada en la zona maxilar anterior debe contar con un mínimo de tabla ósea vestibular que permita una transmisión de esfuerzos sin sobrecarga patológica. Objetivo: Evaluar la distribución de esfuerzos von Mises y microdeformaciones en diferentes espesores de la tabla vestibular en el segmento anterosuperior del maxilar. Métodos: Se utilizó el método de elementos finitos para modelar la zona anterior del maxilar superior con tres diferentes espesores de tabla ósea vestibular (0,5, 1 y 1,5 mm), más una restauración implantosoportada, a la cual se aplicó una carga estática de 200 N (Newtons). Se evaluaron esfuerzos y microdeformaciones de las tablas óseas vestibulares a 2, 4 y 6 mm de la cresta ósea en dirección apical, tanto en el hueso esponjoso como en el cortical. Resultados: De acuerdo al método de elementos finitos se encontró que en el espesor 0,5 mm de tabla ósea vestibular (cortical) y a 2 mm de altura, se presentaron esfuerzos von Mises (31 056 mpa) y microdeformación (2 154 µε), y a medida que el espesor óseo aumentó a 1,5 mm en la altura de 2 mm, se encontró (22 913 mpa y 1 570 µε), esta misma tendencia se observó en las otras dos alturas. Conclusiones: Los mayores valores von Mises y de microdeformación se encontraron en la cresta ósea de la tabla vestibular de 0,5 mm de espesor y disminuyeron a medida que el volumen de hueso esponjoso aumentó en dirección apical.Universidad Nacional Mayor de San Marcos, Facultad de Odontología2018-09-18info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/1515010.15381/os.v21i3.15150Odontología Sanmarquina; Vol. 21 No. 3 (2018); 195-203Odontología Sanmarquina; Vol. 21 Núm. 3 (2018); 195-2031609-86171560-9111reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/15150/13141Derechos de autor 2018 Julio Cesar Escobar Restrepo, Juan David Serna Ceballos, Federico Latorre Correa, Junes Abdul Villarraga Ossahttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/151502018-09-18T12:31:52Z |
dc.title.none.fl_str_mv |
Evaluation of micro strain in different thicknesses of the buccal bone plate Evaluación de la microdeformación según diferentes espesores de la tabla ósea vestibular |
title |
Evaluation of micro strain in different thicknesses of the buccal bone plate |
spellingShingle |
Evaluation of micro strain in different thicknesses of the buccal bone plate Escobar Restrepo, Julio Cesar Análisis de elementos finitos Hueso cortical Implantes dentales Cortical bone Dental implants Finite element analysis |
title_short |
Evaluation of micro strain in different thicknesses of the buccal bone plate |
title_full |
Evaluation of micro strain in different thicknesses of the buccal bone plate |
title_fullStr |
Evaluation of micro strain in different thicknesses of the buccal bone plate |
title_full_unstemmed |
Evaluation of micro strain in different thicknesses of the buccal bone plate |
title_sort |
Evaluation of micro strain in different thicknesses of the buccal bone plate |
dc.creator.none.fl_str_mv |
Escobar Restrepo, Julio Cesar Serna Ceballos, Juan David Latorre Correa, Federico Villarraga Ossa, Junes Abdul |
author |
Escobar Restrepo, Julio Cesar |
author_facet |
Escobar Restrepo, Julio Cesar Serna Ceballos, Juan David Latorre Correa, Federico Villarraga Ossa, Junes Abdul |
author_role |
author |
author2 |
Serna Ceballos, Juan David Latorre Correa, Federico Villarraga Ossa, Junes Abdul |
author2_role |
author author author |
dc.subject.none.fl_str_mv |
Análisis de elementos finitos Hueso cortical Implantes dentales Cortical bone Dental implants Finite element analysis |
topic |
Análisis de elementos finitos Hueso cortical Implantes dentales Cortical bone Dental implants Finite element analysis |
description |
For an implant-supported restoration of the maxillary anterior area; the buccal bone plate should have a minimum thickness to ensure an optimal and predictable behavior of soft tissue. Objective: To evaluate the mechanical behavior of stress and microstrain (von Mises yield criterion); in different thicknesses of buccal maxillary bone plates. Methods: The finite element method was used for modeling the maxillary anterior area with three different buccal bone thickness 0.5, 1 and 1.5 mm. An implant-supported restoration was modeled as well, to which a static load of 200 N was applied. Stress and microstrains were obtained in the buccal bone plates at 2, 4 and 6 mm from the alveolar crest towards the apical direction, both in cancellous and cortical bone. Results: Based on the finite element method, it was found that in the thickness of 0.5 mm of buccal bone plate (cortical) with 2 mms height, results showed stress von Mises (31 056 mpa) and displayed microstrains (2 154 µε). As the thickness increased to 1.5 mm with the 2 mm height results stated (22 913 mpa and 1 570 µε). This same trend was observed in the other two heights. Conclusions: The highest values von Mises and micro deformation were found on the crest of the buccal plate with 0.5 mm thickness and decreasing as the volume of cancellous bone increased towards apical direction. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-09-18 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/15150 10.15381/os.v21i3.15150 |
url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/15150 |
identifier_str_mv |
10.15381/os.v21i3.15150 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/odont/article/view/15150/13141 |
dc.rights.none.fl_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-sa/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Odontología |
publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Odontología |
dc.source.none.fl_str_mv |
Odontología Sanmarquina; Vol. 21 No. 3 (2018); 195-203 Odontología Sanmarquina; Vol. 21 Núm. 3 (2018); 195-203 1609-8617 1560-9111 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
instname_str |
Universidad Nacional Mayor de San Marcos |
instacron_str |
UNMSM |
institution |
UNMSM |
reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
collection |
Revistas - Universidad Nacional Mayor de San Marcos |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1795238211908272128 |
score |
13.949927 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).