MULTIVARIABLE CLOSED-LOOP IDENTIFICATION WITH CONSTRAINED MPC CONTROL: CASE-STUDY ON A C3/C4 SPLITTER

Descripción del Articulo

This paper deals with the model re-identification in closed-loop systems with already existing MPC controllers. lt is assumed that the controller has a two-layer structure where the upper layer performs a simplified economic optimization in which the economic objective is represented as a linear com...

Descripción completa

Detalles Bibliográficos
Autores: Sotomayor, Oscar A. Z., Odloak, Darci, Moro, Lincoln F. L.
Formato: artículo
Fecha de Publicación:2007
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/4276
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/quim/article/view/4276
Nivel de acceso:acceso abierto
Materia:Closed-loop identification
model predictive control
model maintenance
control performance assessment
distillation column.
Identificación de circuito cerrado
modelo de control predictivo
modelo de mantenimiento
evaluación del rendimiento de control
columna de destilación.
Descripción
Sumario:This paper deals with the model re-identification in closed-loop systems with already existing MPC controllers. lt is assumed that the controller has a two-layer structure where the upper layer performs a simplified economic optimization in which the economic objective is represented as a linear combination of the process inputs. This is the case of several commercial MPC packages applied in industry. This work focuses on the case where the existing process model shows signs of deterioration and there is benefit in obtaining a new model. It is proposed a methodology where the test signal is introduced in the coefficients of the objective function of the economic layer. The approach allows the continuous operation of the system as the process constraints and product specification can be satisfied during the test. The application of the method is illustrated by simulation on a C3/C4 splitter of the oil industry. The method is simple to be implemented in existing commercial packages, and the results show that tne method has a good potential to be applied in practice.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).