Eosinophils and temperature in the postoperative period
Descripción del Articulo
In 36 patients who were to be operated, has been tested on test Adrenaline as performance index of the anterior hypothalamus-pituitary-adrenocortical before and after system operation. Furthermore, we have studied the behavior of daily blood eosinophils during postoperative period, temperature relat...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 1952 |
| Institución: | Universidad Nacional Mayor de San Marcos |
| Repositorio: | Revistas - Universidad Nacional Mayor de San Marcos |
| Lenguaje: | español |
| OAI Identifier: | oai:ojs.csi.unmsm:article/9418 |
| Enlace del recurso: | https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/9418 |
| Nivel de acceso: | acceso abierto |
| id |
REVUNMSM_2942ec98679e68ac81489656fcecb3b3 |
|---|---|
| oai_identifier_str |
oai:ojs.csi.unmsm:article/9418 |
| network_acronym_str |
REVUNMSM |
| network_name_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository_id_str |
|
| spelling |
Eosinophils and temperature in the postoperative periodEosinófilos y temperatura en el periodo post-operatorioRamírez del Villar, EduardoMartinelli, VincenzoIn 36 patients who were to be operated, has been tested on test Adrenaline as performance index of the anterior hypothalamus-pituitary-adrenocortical before and after system operation. Furthermore, we have studied the behavior of daily blood eosinophils during postoperative period, temperature related. The Adrenaline Test has been very inconsistent without diagnostic value of functional status before hypothalamus-pituitary-adrenocortical system. For this reason, the test has no prognostic value indicative of the resistance of patients to surgery. Instead, the constant and regular numerical variations of blood eosinophils - opposed to the thermocline - do recommend the routine use of Direct eosinophil count in the postoperative period. Both to control the patient's general condition, the early to discover any possible complications. Four patients with eosinophilia pulmonary echinococcosis were operated not follow the normal numerical variations of blood eosinophils in the second phase of the post-operative period.En 36 enfermos que debían ser operados, se ha ensayado el Test de la Adrenalina, como índice del funcionamiento del Sistema hipotálamo-hipófisis anterior-corticoadrenal, antes y después de la intervención quirúrgica. Además, se ha estudiado diariamente el comportamiento de los eosinófilos sanguíneos durante el período post-operatorio, relacionado con la temperatura. El Test de la Adrenalina se ha mostrado muy inconstante y sin valor diagnóstico del estado funcional del Sistema hipotálamo-hipófisis anterior-corticoadrenal. Por esta razón, dicho Test tampoco posee valor pronóstico indicativo de la resistencia de los enfermos a la intervención quirúrgica. En cambio, las constantes y regulares variaciones numéricas de los eosinófilos sanguíneos - opuestos a la curva térmica - hacen recomendable el uso rutinario del Recuento Directo de los eosinófilos en el período post-operatorio. Tanto para controlar el estado general del enfermo, cuanto para poder descubrir precozmente cualquier posible complicación. Cuatro enfermos de Equinococosis pulmonar con eosinofilia que fueron operados, no siguieron las variaciones numéricas normales de los eosinófilos sanguíneos en la segunda fase del período post-operatorio.Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana1952-12-31info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/941810.15381/anales.v35i4.9418Anales de la Facultad de Medicina; Vol. 35 No. 4 (1952); 423-437Anales de la Facultad de Medicina; Vol. 35 Núm. 4 (1952); 423-4371609-94191025-5583reponame:Revistas - Universidad Nacional Mayor de San Marcosinstname:Universidad Nacional Mayor de San Marcosinstacron:UNMSMspahttps://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/9418/8241Derechos de autor 1952 Eduardo Ramírez del Villar, Vincenzo Martinellihttps://creativecommons.org/licenses/by-nc-sa/4.0info:eu-repo/semantics/openAccessoai:ojs.csi.unmsm:article/94182020-04-06T16:49:05Z |
| dc.title.none.fl_str_mv |
Eosinophils and temperature in the postoperative period Eosinófilos y temperatura en el periodo post-operatorio |
| title |
Eosinophils and temperature in the postoperative period |
| spellingShingle |
Eosinophils and temperature in the postoperative period Ramírez del Villar, Eduardo |
| title_short |
Eosinophils and temperature in the postoperative period |
| title_full |
Eosinophils and temperature in the postoperative period |
| title_fullStr |
Eosinophils and temperature in the postoperative period |
| title_full_unstemmed |
Eosinophils and temperature in the postoperative period |
| title_sort |
Eosinophils and temperature in the postoperative period |
| dc.creator.none.fl_str_mv |
Ramírez del Villar, Eduardo Martinelli, Vincenzo |
| author |
Ramírez del Villar, Eduardo |
| author_facet |
Ramírez del Villar, Eduardo Martinelli, Vincenzo |
| author_role |
author |
| author2 |
Martinelli, Vincenzo |
| author2_role |
author |
| description |
In 36 patients who were to be operated, has been tested on test Adrenaline as performance index of the anterior hypothalamus-pituitary-adrenocortical before and after system operation. Furthermore, we have studied the behavior of daily blood eosinophils during postoperative period, temperature related. The Adrenaline Test has been very inconsistent without diagnostic value of functional status before hypothalamus-pituitary-adrenocortical system. For this reason, the test has no prognostic value indicative of the resistance of patients to surgery. Instead, the constant and regular numerical variations of blood eosinophils - opposed to the thermocline - do recommend the routine use of Direct eosinophil count in the postoperative period. Both to control the patient's general condition, the early to discover any possible complications. Four patients with eosinophilia pulmonary echinococcosis were operated not follow the normal numerical variations of blood eosinophils in the second phase of the post-operative period. |
| publishDate |
1952 |
| dc.date.none.fl_str_mv |
1952-12-31 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/9418 10.15381/anales.v35i4.9418 |
| url |
https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/9418 |
| identifier_str_mv |
10.15381/anales.v35i4.9418 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/9418/8241 |
| dc.rights.none.fl_str_mv |
Derechos de autor 1952 Eduardo Ramírez del Villar, Vincenzo Martinelli https://creativecommons.org/licenses/by-nc-sa/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 1952 Eduardo Ramírez del Villar, Vincenzo Martinelli https://creativecommons.org/licenses/by-nc-sa/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana |
| publisher.none.fl_str_mv |
Universidad Nacional Mayor de San Marcos, Facultad de Medicina Humana |
| dc.source.none.fl_str_mv |
Anales de la Facultad de Medicina; Vol. 35 No. 4 (1952); 423-437 Anales de la Facultad de Medicina; Vol. 35 Núm. 4 (1952); 423-437 1609-9419 1025-5583 reponame:Revistas - Universidad Nacional Mayor de San Marcos instname:Universidad Nacional Mayor de San Marcos instacron:UNMSM |
| instname_str |
Universidad Nacional Mayor de San Marcos |
| instacron_str |
UNMSM |
| institution |
UNMSM |
| reponame_str |
Revistas - Universidad Nacional Mayor de San Marcos |
| collection |
Revistas - Universidad Nacional Mayor de San Marcos |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1795238250148790272 |
| score |
13.934708 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).