Mechanical and experimental development of a flexible cervical disc implant

Descripción del Articulo

Introduction: Cervical arthroplasty is a surgical procedure that involves the use of disc implants with the capacity of preserving segmental movement. It is a challenge for countries like ours to develop alternatives to the high costs of the aforementioned implants, with patented d...

Descripción completa

Detalles Bibliográficos
Autores: Alvarez, Carlos, Lean, Paul, Rodríguez, Rodolfo, Pacussich, Claudio, Noriega, Ainsworth, Navarro, Erick
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Nacional Mayor de San Marcos
Repositorio:Revistas - Universidad Nacional Mayor de San Marcos
Lenguaje:español
OAI Identifier:oai:ojs.csi.unmsm:article/16105
Enlace del recurso:https://revistasinvestigacion.unmsm.edu.pe/index.php/anales/article/view/16105
Nivel de acceso:acceso abierto
Materia:Prótesis e Implantes; Artroplastia de Reemplazo; Diseño de Prótesis; Ensayo de Materiales; Estructuras Animales; Modelos Animales
Prostheses and Implants; Arthroplasty, Replacement; Prosthesis Design; Materials Testing; Animal Structures; Models, Animal
Descripción
Sumario:Introduction: Cervical arthroplasty is a surgical procedure that involves the use of disc implants with the capacity of preserving segmental movement. It is a challenge for countries like ours to develop alternatives to the high costs of the aforementioned implants, with patented designs, feasible to manufacture, with biocompatibility, safety, and that simulates as much as possible the physiological cervical movements. Objectives: To develop the geometry and mechanics of a patented disc design elaborated with titanium ELI by additive manufacturing, as well as, to verify its compatibility with the physiology of cervical movements. Methods: The study design had three iterative stages: the first one was the development of the implant geometry and the finite-element study using international standards as a reference. In second place, studies of metallography, characterization of the material and fatigue tests of the implant were developed. Finally, a cadaverous animal model was used to confirm the compatibility of the implant with cervical movements. Results: The implants manufactured by forging or by additive manufacturing are compatible with international standards. 84 x-ray studies were performed on 18 pig necks. In 100% of the cervical columns of the pigs, the range in flexion was smaller than that of extension. There was a greater range of motion when two implants were used and when the implant was larger. Conclusions: The flexible cervical implant made by forging or a titanium-ELI additive manufacturing have promising results, because of that, an experimental use in patients, who needs cervical arthroplasty, could be considered.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).