Microhiological contamination (fecal coliforms) of soils due to the use of wastewater from the Arunta retention ponds, Tacna
Descripción del Articulo
ABSTRACT The bacteriological contamination of the soils in the Arunta area was evaluated experimentally. For the research, the experimental variables considered were time (day) and the dosage of wastewater from the Arunta ponds (l/m2/day), which are the cause of bacteriological contamination. For th...
Autores: | , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2024 |
Institución: | Universidad Nacional Jorge Basadre Grohmann |
Repositorio: | Revistas - Universidad Nacional Jorge Basadre Grohmann |
Lenguaje: | español |
OAI Identifier: | oai:revistas.unjbg.edu.pe:article/2082 |
Enlace del recurso: | https://revistas.unjbg.edu.pe/index.php/cyd/article/view/2082 |
Nivel de acceso: | acceso abierto |
Materia: | Diseño hexagonal Aguas residuales Velocidad de contaminación del suelo hexagonal design, wastewater, and soil contamination rate |
Sumario: | ABSTRACT The bacteriological contamination of the soils in the Arunta area was evaluated experimentally. For the research, the experimental variables considered were time (day) and the dosage of wastewater from the Arunta ponds (l/m2/day), which are the cause of bacteriological contamination. For the experimental research with the objective of modeling the speed of bacteriological contamination, the hexagonal design was used. Table 3 presents the experimental conditions of the variables and the results of the increase in soil contamination. The wastewater used for irrigation in Arunta, with a high contamination of 35,000,000 mg coliforms/l, dosed from 3.00 to 6.00 liters/m2/day and for a time varying from 33.61 to 54.39, increases the bacteriological contamination of the soil from 93.44% to 779.78%. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).