Focus of Pi controllers on direct vector control of Induction Motors

Descripción del Articulo

Since it's invention, the Field Orientation Vector Control has been usefully for controlling Induction Machines (IM) for high dynamic performance. Among Field Orientation Vector Control methods. one uses leakage rotor referential flux, in order to reduce non linear model equations of IM to a sy...

Descripción completa

Detalles Bibliográficos
Autor: Soto Lock, Alberto
Formato: artículo
Fecha de Publicación:2002
Institución:Universidad Nacional de Ingeniería
Repositorio:Revistas - Universidad Nacional de Ingeniería
Lenguaje:español
OAI Identifier:oai:oai:revistas.uni.edu.pe:article/498
Enlace del recurso:https://revistas.uni.edu.pe/index.php/tecnia/article/view/498
Nivel de acceso:acceso abierto
id REVUNI_d9e3216d573c1349d8cbf858a204307e
oai_identifier_str oai:oai:revistas.uni.edu.pe:article/498
network_acronym_str REVUNI
network_name_str Revistas - Universidad Nacional de Ingeniería
repository_id_str
spelling Focus of Pi controllers on direct vector control of Induction MotorsEnfoque de los controladores Pi en el control vectorial directo de Motores de InducciónSoto Lock, AlbertoSince it's invention, the Field Orientation Vector Control has been usefully for controlling Induction Machines (IM) for high dynamic performance. Among Field Orientation Vector Control methods. one uses leakage rotor referential flux, in order to reduce non linear model equations of IM to a system based on dq axes model, similar to DC motor. On this article, it is show fundamentals of this Vector Control method as well as a method for calibrating Proportional Integral controllers in order to archive a high dynamic performance IM control.Desde su invención, el control vectorial ha sido una herramienta muy útil para controlar la Máquina de Inducción (MI) tanto en el estado estacionario como en el transitorio. Uno de los métodos de control vectorial es el que usa como referencia el flujo concatenado por el rotor consiguiendo de este modo reducir la planta no lineal de la MI a un sistema referido a los ejes dq. semejante a la máquina de corriente continua(c.c). Este artículo, además de ilustrar los fundamentos teóricos de este método de control vectorial, muestra un enfoque que pueden tener los controladores Proporcional Integral para controlar la MI, a fin de que se obtenga un alto rendimiento dinámico.Universidad Nacional de Ingeniería2002-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/49810.21754/tecnia.v12i2.498TECNIA; Vol. 12 No. 2 (2002)TECNIA; Vol. 12 Núm. 2 (2002)2309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/498/465Derechos de autor 2002 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/4982023-12-04T15:27:07Z
dc.title.none.fl_str_mv Focus of Pi controllers on direct vector control of Induction Motors
Enfoque de los controladores Pi en el control vectorial directo de Motores de Inducción
title Focus of Pi controllers on direct vector control of Induction Motors
spellingShingle Focus of Pi controllers on direct vector control of Induction Motors
Soto Lock, Alberto
title_short Focus of Pi controllers on direct vector control of Induction Motors
title_full Focus of Pi controllers on direct vector control of Induction Motors
title_fullStr Focus of Pi controllers on direct vector control of Induction Motors
title_full_unstemmed Focus of Pi controllers on direct vector control of Induction Motors
title_sort Focus of Pi controllers on direct vector control of Induction Motors
dc.creator.none.fl_str_mv Soto Lock, Alberto
author Soto Lock, Alberto
author_facet Soto Lock, Alberto
author_role author
description Since it's invention, the Field Orientation Vector Control has been usefully for controlling Induction Machines (IM) for high dynamic performance. Among Field Orientation Vector Control methods. one uses leakage rotor referential flux, in order to reduce non linear model equations of IM to a system based on dq axes model, similar to DC motor. On this article, it is show fundamentals of this Vector Control method as well as a method for calibrating Proportional Integral controllers in order to archive a high dynamic performance IM control.
publishDate 2002
dc.date.none.fl_str_mv 2002-12-01
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Artículo evaluado por pares
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/498
10.21754/tecnia.v12i2.498
url https://revistas.uni.edu.pe/index.php/tecnia/article/view/498
identifier_str_mv 10.21754/tecnia.v12i2.498
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.uni.edu.pe/index.php/tecnia/article/view/498/465
dc.rights.none.fl_str_mv Derechos de autor 2002 TECNIA
http://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2002 TECNIA
http://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Nacional de Ingeniería
publisher.none.fl_str_mv Universidad Nacional de Ingeniería
dc.source.none.fl_str_mv TECNIA; Vol. 12 No. 2 (2002)
TECNIA; Vol. 12 Núm. 2 (2002)
2309-0413
0375-7765
reponame:Revistas - Universidad Nacional de Ingeniería
instname:Universidad Nacional de Ingeniería
instacron:UNI
instname_str Universidad Nacional de Ingeniería
instacron_str UNI
institution UNI
reponame_str Revistas - Universidad Nacional de Ingeniería
collection Revistas - Universidad Nacional de Ingeniería
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1833562778166624256
score 13.88985
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).