Induction Motor Speed Control Using Direct Torque Control (DTC) Method
Descripción del Articulo
Field orientation control is a technique used in AC servo mechanisms that makes it possible to achieve a rapid torque response because it is based on the interaction between flux and current as in a DC motor. An alternative for servo controlmechanisms in AC is the Direct Torque Control that represen...
| Autores: | , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2002 |
| Institución: | Universidad Nacional de Ingeniería |
| Repositorio: | Revistas - Universidad Nacional de Ingeniería |
| Lenguaje: | español |
| OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/500 |
| Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/500 |
| Nivel de acceso: | acceso abierto |
| id |
REVUNI_bdfa7a2f7058bf121b5ec4ee2cfb2714 |
|---|---|
| oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/500 |
| network_acronym_str |
REVUNI |
| network_name_str |
Revistas - Universidad Nacional de Ingeniería |
| repository_id_str |
|
| spelling |
Induction Motor Speed Control Using Direct Torque Control (DTC) MethodControl de velocidad de Motor de Inducción usando el Método Directo de Control de Torque (DTC)Mendoza B, MarioMoreno M., RodolfoField orientation control is a technique used in AC servo mechanisms that makes it possible to achieve a rapid torque response because it is based on the interaction between flux and current as in a DC motor. An alternative for servo controlmechanisms in AC is the Direct Torque Control that represents an advance in the objective of improving the performance and reliability in the control of induction motors and is fundamentally based on the comparison of the instantaneous values of Torque and Flow, calculated from of its primary variables (stator voltage and current), with their respective reference values. The resulting Flow and Torque errors are processed by hysteresis controllers to then select the voltage to be applied, through the activation of the power switches of a three-phase voltage inverter. The selection criteria are made so that there is a rapid torque response and high efficiency operation simultaneously. The objective of this article is to show the simulation results obtained from the study of Direct Torque Control for high-performance AC controller applications.El control por orientación de campo es una técnica empleada en los servos mecanismos en CA que posibilita alcanzar una respuesta rápida de torque debido a que se basa en la interacción entre flujo y corriente como en un motor CC. Una alternativa para el control de los servosmecanismos en CA es el Control Directo de Torque que representa un avance en el objetivo de mejorar el desempeño y confiabilidad en el control de motores de inducción y que se basa fundamentalmente en la comparación de los valores instantáneos, de Torque y Flujo, calculados a partir de sus variables primarias (voltaje y corriente de estator), con sus respectivos valores de referencia. Los errores de Flujo y Torque resultantes son procesados por controladores por histéresis para luego seleccionar el voltaje a ser aplicado, a través del accionamiento de las llaves de potencia de un Inversor trifásico de tensión. Los criterios de selección son realizados de modo que se tenga una rápida respuesta de torque y una operación de alta eficiencia simultáneamente. El presente artículo tiene por objetivo mostrar los resultados de simulación obtenidos del estudio del Control Directo de Torque para aplicaciones de controladores en AC de alto desempeño.Universidad Nacional de Ingeniería2002-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/50010.21754/tecnia.v12i1.500TECNIA; Vol. 12 No. 1 (2002)TECNIA; Vol. 12 Núm. 1 (2002)2309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/500/476Derechos de autor 2002 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/5002023-12-04T14:34:09Z |
| dc.title.none.fl_str_mv |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method Control de velocidad de Motor de Inducción usando el Método Directo de Control de Torque (DTC) |
| title |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method |
| spellingShingle |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method Mendoza B, Mario |
| title_short |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method |
| title_full |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method |
| title_fullStr |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method |
| title_full_unstemmed |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method |
| title_sort |
Induction Motor Speed Control Using Direct Torque Control (DTC) Method |
| dc.creator.none.fl_str_mv |
Mendoza B, Mario Moreno M., Rodolfo |
| author |
Mendoza B, Mario |
| author_facet |
Mendoza B, Mario Moreno M., Rodolfo |
| author_role |
author |
| author2 |
Moreno M., Rodolfo |
| author2_role |
author |
| description |
Field orientation control is a technique used in AC servo mechanisms that makes it possible to achieve a rapid torque response because it is based on the interaction between flux and current as in a DC motor. An alternative for servo controlmechanisms in AC is the Direct Torque Control that represents an advance in the objective of improving the performance and reliability in the control of induction motors and is fundamentally based on the comparison of the instantaneous values of Torque and Flow, calculated from of its primary variables (stator voltage and current), with their respective reference values. The resulting Flow and Torque errors are processed by hysteresis controllers to then select the voltage to be applied, through the activation of the power switches of a three-phase voltage inverter. The selection criteria are made so that there is a rapid torque response and high efficiency operation simultaneously. The objective of this article is to show the simulation results obtained from the study of Direct Torque Control for high-performance AC controller applications. |
| publishDate |
2002 |
| dc.date.none.fl_str_mv |
2002-06-01 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/500 10.21754/tecnia.v12i1.500 |
| url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/500 |
| identifier_str_mv |
10.21754/tecnia.v12i1.500 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/500/476 |
| dc.rights.none.fl_str_mv |
Derechos de autor 2002 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Derechos de autor 2002 TECNIA http://creativecommons.org/licenses/by/4.0 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
| dc.source.none.fl_str_mv |
TECNIA; Vol. 12 No. 1 (2002) TECNIA; Vol. 12 Núm. 1 (2002) 2309-0413 0375-7765 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
| instname_str |
Universidad Nacional de Ingeniería |
| instacron_str |
UNI |
| institution |
UNI |
| reponame_str |
Revistas - Universidad Nacional de Ingeniería |
| collection |
Revistas - Universidad Nacional de Ingeniería |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1833562778172915712 |
| score |
13.905277 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).