Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry.
Descripción del Articulo
The implementation of a test method ensures the analytical reliability of the test result, reason why the present paper deals with the implementation of the analytical method described in the Standard Methods 3111 D - Direct Nitrous Oxide - Acetylene Flame Method for the determination of barium in t...
Autores: | , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2014 |
Institución: | Universidad Nacional de Ingeniería |
Repositorio: | Revistas - Universidad Nacional de Ingeniería |
Lenguaje: | español |
OAI Identifier: | oai:oai:revistas.uni.edu.pe:article/28 |
Enlace del recurso: | https://revistas.uni.edu.pe/index.php/tecnia/article/view/28 |
Nivel de acceso: | acceso abierto |
Materia: | ISO/IEC 17025 espectrómetro de absorción atómica bario implementación límite de detección del método agua residual atomic absorption spectrometer barium implementation method detection limit wastewater |
id |
REVUNI_82ff0152cac635a0417d148854c3607a |
---|---|
oai_identifier_str |
oai:oai:revistas.uni.edu.pe:article/28 |
network_acronym_str |
REVUNI |
network_name_str |
Revistas - Universidad Nacional de Ingeniería |
repository_id_str |
|
spelling |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry.Implementación de la técnica analítica bario en agua residual por espectrometría de absorción atómicaCamero Jiménez, José W.Huamaní León, Víctor A.ISO/IEC 17025espectrómetro de absorción atómicabarioimplementaciónlímite de detección del métodoagua residualISO/IEC 17025atomic absorption spectrometerbariumimplementationmethod detection limitwastewaterThe implementation of a test method ensures the analytical reliability of the test result, reason why the present paper deals with the implementation of the analytical method described in the Standard Methods 3111 D - Direct Nitrous Oxide - Acetylene Flame Method for the determination of barium in the matrix of wastewater, using an atomic absorption spectrometer. It is implementation has the approach of the system of management of quality of testing laboratories ISO/IEC 17025: 2005, being evaluated statistical parameters: accuracy (trueness and precision), method detection limit, quantification limit, working range, linearity, sensitivity and robustness. La implementación de un método de ensayo asegura la confiabilidad analítica del resultado de ensayo, razón por la cual el presente trabajo aborda la implementación del método analítico descrito en el Standard Methods 3111 D - Direct Nitrous Oxide - Acetylene Flame Method para la determinación de bario, en la matriz de agua residual, utilizando un espectrómetro de absorción atómica. Está implementación tiene el enfoque del sistema de gestión de calidad de laboratorios de ensayo ISO/IEC 17025:2005, siendo los parámetros estadísticos evaluados: la exactitud (veracidad y precisión), límite de detección del método, límite de cuantificación, rango de trabajo, linealidad, sensibilidad y robustez.Universidad Nacional de Ingeniería2014-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionArtículo evaluado por paresapplication/pdfhttps://revistas.uni.edu.pe/index.php/tecnia/article/view/2810.21754/tecnia.v24i1.28TECNIA; Vol. 24 No. 1 (2014); 21TECNIA; Vol. 24 Núm. 1 (2014); 212309-04130375-7765reponame:Revistas - Universidad Nacional de Ingenieríainstname:Universidad Nacional de Ingenieríainstacron:UNIspahttps://revistas.uni.edu.pe/index.php/tecnia/article/view/28/24Derechos de autor 2014 TECNIAhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessoai:oai:revistas.uni.edu.pe:article/282023-12-06T15:05:37Z |
dc.title.none.fl_str_mv |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. Implementación de la técnica analítica bario en agua residual por espectrometría de absorción atómica |
title |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. |
spellingShingle |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. Camero Jiménez, José W. ISO/IEC 17025 espectrómetro de absorción atómica bario implementación límite de detección del método agua residual ISO/IEC 17025 atomic absorption spectrometer barium implementation method detection limit wastewater |
title_short |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. |
title_full |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. |
title_fullStr |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. |
title_full_unstemmed |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. |
title_sort |
Implementation of the barium analytical technique in wastewater by atomic absorption spectrometry. |
dc.creator.none.fl_str_mv |
Camero Jiménez, José W. Huamaní León, Víctor A. |
author |
Camero Jiménez, José W. |
author_facet |
Camero Jiménez, José W. Huamaní León, Víctor A. |
author_role |
author |
author2 |
Huamaní León, Víctor A. |
author2_role |
author |
dc.subject.none.fl_str_mv |
ISO/IEC 17025 espectrómetro de absorción atómica bario implementación límite de detección del método agua residual ISO/IEC 17025 atomic absorption spectrometer barium implementation method detection limit wastewater |
topic |
ISO/IEC 17025 espectrómetro de absorción atómica bario implementación límite de detección del método agua residual ISO/IEC 17025 atomic absorption spectrometer barium implementation method detection limit wastewater |
description |
The implementation of a test method ensures the analytical reliability of the test result, reason why the present paper deals with the implementation of the analytical method described in the Standard Methods 3111 D - Direct Nitrous Oxide - Acetylene Flame Method for the determination of barium in the matrix of wastewater, using an atomic absorption spectrometer. It is implementation has the approach of the system of management of quality of testing laboratories ISO/IEC 17025: 2005, being evaluated statistical parameters: accuracy (trueness and precision), method detection limit, quantification limit, working range, linearity, sensitivity and robustness. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-06-01 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion Artículo evaluado por pares |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/28 10.21754/tecnia.v24i1.28 |
url |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/28 |
identifier_str_mv |
10.21754/tecnia.v24i1.28 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.uni.edu.pe/index.php/tecnia/article/view/28/24 |
dc.rights.none.fl_str_mv |
Derechos de autor 2014 TECNIA http://creativecommons.org/licenses/by/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2014 TECNIA http://creativecommons.org/licenses/by/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
publisher.none.fl_str_mv |
Universidad Nacional de Ingeniería |
dc.source.none.fl_str_mv |
TECNIA; Vol. 24 No. 1 (2014); 21 TECNIA; Vol. 24 Núm. 1 (2014); 21 2309-0413 0375-7765 reponame:Revistas - Universidad Nacional de Ingeniería instname:Universidad Nacional de Ingeniería instacron:UNI |
instname_str |
Universidad Nacional de Ingeniería |
instacron_str |
UNI |
institution |
UNI |
reponame_str |
Revistas - Universidad Nacional de Ingeniería |
collection |
Revistas - Universidad Nacional de Ingeniería |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1833562773279211520 |
score |
13.914502 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).