Numerical simulation of velocity field in a arteriouvenous fístula
Descripción del Articulo
The objective of this study is to analyze the hemodynamic factors of flow in an arteriovenous fistula (AVF). The geometric model of the AVF is obtained virtually from a computed tomography. In the mathematical model, which simulates blood flow in the AVF, it is considered a non-Newtonian fluid, inco...
Autores: | , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2019 |
Institución: | Universidad Nacional de Trujillo |
Repositorio: | Revistas - Universidad Nacional de Trujillo |
Lenguaje: | español |
OAI Identifier: | oai:ojs.revistas.unitru.edu.pe:article/2452 |
Enlace del recurso: | https://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452 |
Nivel de acceso: | acceso abierto |
Materia: | Arteriovenous fistula Velocity field CFD Fístula Arteriovesa Campo de Velocidade DFC |
id |
REVUNITRU_c4e5b90f328f7de06361bc43b68bf7a2 |
---|---|
oai_identifier_str |
oai:ojs.revistas.unitru.edu.pe:article/2452 |
network_acronym_str |
REVUNITRU |
network_name_str |
Revistas - Universidad Nacional de Trujillo |
repository_id_str |
|
spelling |
Numerical simulation of velocity field in a arteriouvenous fístulaSimulacao numérica do campo de velocidade em fístula arteriovenosaA. Santos, Willyam B.M. Borjas, Santos D.C. Moreira, Ricardo W.L. Bessa, KleiberArteriovenous fistulaVelocity fieldCFDFístula ArteriovesaCampo de VelocidadeDFCThe objective of this study is to analyze the hemodynamic factors of flow in an arteriovenous fistula (AVF). The geometric model of the AVF is obtained virtually from a computed tomography. In the mathematical model, which simulates blood flow in the AVF, it is considered a non-Newtonian fluid, incompressible and transient laminar flow. The flow behavior in the AVF is given by the blood velocity in five points corresponding to the mass flow in the systolic phase and in the diastolic phase. The numerical simulation of the velocity field in the systolic phasepresented greater intensity of axial and radial recirculations. The presence of recirculations allows figurative elements to collide excessively in the wall of the endotheliumO objetivo deste trabalho e analisar os fatores hemodinamicos do escoamento numa fístula arteriovenosa (FAV). O modelo geométrico da FAV é obtido virtualmente a partir de uma tomografia computadorizada. No modelo matemático, que simula o fluxo da sangue na FAV, é considerado um fluido nao-Newtoniano, escoamento laminar, incompressível e em regime transiente. O comportamento do fluxo na FAV é dado pela velocidade do sangue em cinco pontos correspondente á vazao mássica em fase sistólica e em fase diastólica. A simulacao numérica do campo de velocidade na fase sistólica apresentou maior intensidade de recirculacoes axiais e radiais. A presenca de recirculacoes permite que elementos figurados se choquem excessivamente na parede do endotélio.National University of Trujillo - Academic Department of Mathematics2019-07-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlhttps://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452Selecciones Matemáticas; Vol. 6 No. 01 (2019): January - July; 98-107Selecciones Matemáticas; Vol. 6 Núm. 01 (2019): Enero-Julio; 98-107Selecciones Matemáticas; v. 6 n. 01 (2019): Enero-Julio; 98-1072411-1783reponame:Revistas - Universidad Nacional de Trujilloinstname:Universidad Nacional de Trujilloinstacron:UNITRUspahttps://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2487https://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2504Derechos de autor 2019 Selecciones Matemáticasinfo:eu-repo/semantics/openAccessoai:ojs.revistas.unitru.edu.pe:article/24522022-10-21T18:52:41Z |
dc.title.none.fl_str_mv |
Numerical simulation of velocity field in a arteriouvenous fístula Simulacao numérica do campo de velocidade em fístula arteriovenosa |
title |
Numerical simulation of velocity field in a arteriouvenous fístula |
spellingShingle |
Numerical simulation of velocity field in a arteriouvenous fístula A. Santos, Willyam B. Arteriovenous fistula Velocity field CFD Fístula Arteriovesa Campo de Velocidade DFC |
title_short |
Numerical simulation of velocity field in a arteriouvenous fístula |
title_full |
Numerical simulation of velocity field in a arteriouvenous fístula |
title_fullStr |
Numerical simulation of velocity field in a arteriouvenous fístula |
title_full_unstemmed |
Numerical simulation of velocity field in a arteriouvenous fístula |
title_sort |
Numerical simulation of velocity field in a arteriouvenous fístula |
dc.creator.none.fl_str_mv |
A. Santos, Willyam B. M. Borjas, Santos D. C. Moreira, Ricardo W. L. Bessa, Kleiber |
author |
A. Santos, Willyam B. |
author_facet |
A. Santos, Willyam B. M. Borjas, Santos D. C. Moreira, Ricardo W. L. Bessa, Kleiber |
author_role |
author |
author2 |
M. Borjas, Santos D. C. Moreira, Ricardo W. L. Bessa, Kleiber |
author2_role |
author author author |
dc.subject.none.fl_str_mv |
Arteriovenous fistula Velocity field CFD Fístula Arteriovesa Campo de Velocidade DFC |
topic |
Arteriovenous fistula Velocity field CFD Fístula Arteriovesa Campo de Velocidade DFC |
description |
The objective of this study is to analyze the hemodynamic factors of flow in an arteriovenous fistula (AVF). The geometric model of the AVF is obtained virtually from a computed tomography. In the mathematical model, which simulates blood flow in the AVF, it is considered a non-Newtonian fluid, incompressible and transient laminar flow. The flow behavior in the AVF is given by the blood velocity in five points corresponding to the mass flow in the systolic phase and in the diastolic phase. The numerical simulation of the velocity field in the systolic phasepresented greater intensity of axial and radial recirculations. The presence of recirculations allows figurative elements to collide excessively in the wall of the endothelium |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-07-21 |
dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.none.fl_str_mv |
https://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452 |
url |
https://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452 |
dc.language.none.fl_str_mv |
spa |
language |
spa |
dc.relation.none.fl_str_mv |
https://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2487 https://revistas.unitru.edu.pe/index.php/SSMM/article/view/2452/2504 |
dc.rights.none.fl_str_mv |
Derechos de autor 2019 Selecciones Matemáticas info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
Derechos de autor 2019 Selecciones Matemáticas |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf text/html |
dc.publisher.none.fl_str_mv |
National University of Trujillo - Academic Department of Mathematics |
publisher.none.fl_str_mv |
National University of Trujillo - Academic Department of Mathematics |
dc.source.none.fl_str_mv |
Selecciones Matemáticas; Vol. 6 No. 01 (2019): January - July; 98-107 Selecciones Matemáticas; Vol. 6 Núm. 01 (2019): Enero-Julio; 98-107 Selecciones Matemáticas; v. 6 n. 01 (2019): Enero-Julio; 98-107 2411-1783 reponame:Revistas - Universidad Nacional de Trujillo instname:Universidad Nacional de Trujillo instacron:UNITRU |
instname_str |
Universidad Nacional de Trujillo |
instacron_str |
UNITRU |
institution |
UNITRU |
reponame_str |
Revistas - Universidad Nacional de Trujillo |
collection |
Revistas - Universidad Nacional de Trujillo |
repository.name.fl_str_mv |
|
repository.mail.fl_str_mv |
|
_version_ |
1843350202576011264 |
score |
12.860346 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).