Thermal comfort in an adobe room with heat storage system in the Andes of Peru
Descripción del Articulo
The objective of this work was the evaluation of thermal comfort inside the test room (HP), of adobe and materials of the high Andean area of Peru, like the andesite stone that is a heat accumulator. This experimental research work determined the values of thermal conductivity 0,176 0,149...
| Autores: | , , |
|---|---|
| Formato: | artículo |
| Fecha de Publicación: | 2018 |
| Institución: | Universidad Nacional del Altiplano |
| Repositorio: | Revistas Universidad Nacional del Altiplano |
| Lenguaje: | español |
| OAI Identifier: | oai:huajsapata.unap.edu.pe:article/55 |
| Enlace del recurso: | https://huajsapata.unap.edu.pe/index.php/ria/article/view/55 |
| Nivel de acceso: | acceso abierto |
| Materia: | Thermal accumulator specific heat thermal conductivity room with thermal comfort adobe building materials Acumulador térmico calor especifico habitación con confort térmico materiales de construcción de adobe |
| id |
REVUNAP_44406343ddddd4e18f0dfca8b251d323 |
|---|---|
| oai_identifier_str |
oai:huajsapata.unap.edu.pe:article/55 |
| network_acronym_str |
REVUNAP |
| repository_id_str |
|
| network_name_str |
Revistas Universidad Nacional del Altiplano |
| dc.title.none.fl_str_mv |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru Confort térmico en una habitación de adobe con sistema de almacenamiento de calor en los Andes del Perú |
| title |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru |
| spellingShingle |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru Holguino Huarza, Antonio Thermal accumulator specific heat thermal conductivity room with thermal comfort adobe building materials Acumulador térmico calor especifico habitación con confort térmico materiales de construcción de adobe |
| title_short |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru |
| title_full |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru |
| title_fullStr |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru |
| title_full_unstemmed |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru |
| title_sort |
Thermal comfort in an adobe room with heat storage system in the Andes of Peru |
| dc.creator.none.fl_str_mv |
Holguino Huarza, Antonio Olivera Marocho, Luís Escobar Copa, Katterine Ursula |
| author |
Holguino Huarza, Antonio |
| author_facet |
Holguino Huarza, Antonio Olivera Marocho, Luís Escobar Copa, Katterine Ursula |
| author_role |
author |
| author2 |
Olivera Marocho, Luís Escobar Copa, Katterine Ursula |
| author2_role |
author author |
| dc.subject.none.fl_str_mv |
Thermal accumulator specific heat thermal conductivity room with thermal comfort adobe building materials Acumulador térmico calor especifico habitación con confort térmico materiales de construcción de adobe |
| topic |
Thermal accumulator specific heat thermal conductivity room with thermal comfort adobe building materials Acumulador térmico calor especifico habitación con confort térmico materiales de construcción de adobe |
| dc.description.none.fl_txt_mv |
The objective of this work was the evaluation of thermal comfort inside the test room (HP), of adobe and materials of the high Andean area of Peru, like the andesite stone that is a heat accumulator. This experimental research work determined the values of thermal conductivity 0,176 0,149 and 0,118 W / mK for the adobe, plaster and straw. It was made a comparison was made between the values of thermal conductivity and specific heat, obtained experimentally for the materials and systems used in the construction of HP with the known values of specific materials such as water and air. The design and use of the materials in the construction of the wall, door and window, allowed to determine the values of the thermal conductivities equal to 0,061 0,030 and 0,027 W / mK respectively, that are similar to the thermal conductivity of a natural thermal insulator such as air whose value is 0.026 W / mK. The transfer of heat energy to the outside of the HP, during 11 hours at night is 0,815 MJ. The energy accumulator installed in the HP built with stone, guano and wood whose specific heat values were 1235,13 2416,44 and 2212,77 J / kgK respectively compared with the water, that is a good energy storage, that represent 29,55 57,81 and 52,94% respectively. The HP storage system stores heat energy equivalent to 8,305 MJ, the surplus of heat energy allows that temperature inside HP during the winter times to have average values higher in 63, 83 and 68, 83% at the average temperatures of HC and MAC respectively. El objetivo de este trabajo fue la evaluación del confort térmico al interior de la habitación de prueba (HP) de adobe y materiales de la zona alto andina del Perú, como la piedra andesita que es un acumulador de calor. Esta investigación experimental, determinó los valores de la conductividad térmica 0,176 0,149 y 0,118 W/mK para el adobe, yeso y paja. Se efectuó una comparación entre los valores de la conductividad térmica y calor específico, obtenido experimentalmente para los materiales y sistemas utilizados en la construcción de HP con los valores conocidos de materiales específicos como el agua y el aire. El diseño y uso de los materiales en la construcción de la pared, puerta y ventana, permitieron determinar los valores de las conductividades térmicas iguales a 0,061 0,030 y 0,027 W/mK respectivamente, que son similares a la conductividad térmica de un aislante térmico natural como el aire cuyo valor es 0,026 W/mK. La trasferencia de energía calorífica hacia el exterior de la HP, durante 11 horas nocturnas es 0,815 MJ. El acumulador de energía instalado en la HP construido con piedra, guano y madera cuyos valores del calor específico fueron 1235,13 2416,44 y 2212,77 J/kgK respectivamente; comparada con la del agua que es un buen almacenador de energía, representan 29,55; 57,81 y 52,94 % respectivamente. El sistema acumulador de HP almacena energía calorífica equivalente a 8,305 MJ, el excedente de energía calorífica permite que la temperatura al interior de HP durante las épocas de invierno tenga valores medio mayores en 63,83 y 68,83 % a las temperaturas medias de HC y MAC respectivamente. |
| description |
The objective of this work was the evaluation of thermal comfort inside the test room (HP), of adobe and materials of the high Andean area of Peru, like the andesite stone that is a heat accumulator. This experimental research work determined the values of thermal conductivity 0,176 0,149 and 0,118 W / mK for the adobe, plaster and straw. It was made a comparison was made between the values of thermal conductivity and specific heat, obtained experimentally for the materials and systems used in the construction of HP with the known values of specific materials such as water and air. The design and use of the materials in the construction of the wall, door and window, allowed to determine the values of the thermal conductivities equal to 0,061 0,030 and 0,027 W / mK respectively, that are similar to the thermal conductivity of a natural thermal insulator such as air whose value is 0.026 W / mK. The transfer of heat energy to the outside of the HP, during 11 hours at night is 0,815 MJ. The energy accumulator installed in the HP built with stone, guano and wood whose specific heat values were 1235,13 2416,44 and 2212,77 J / kgK respectively compared with the water, that is a good energy storage, that represent 29,55 57,81 and 52,94% respectively. The HP storage system stores heat energy equivalent to 8,305 MJ, the surplus of heat energy allows that temperature inside HP during the winter times to have average values higher in 63, 83 and 68, 83% at the average temperatures of HC and MAC respectively. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018-07-27 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://huajsapata.unap.edu.pe/index.php/ria/article/view/55 |
| url |
https://huajsapata.unap.edu.pe/index.php/ria/article/view/55 |
| dc.language.none.fl_str_mv |
spa |
| language |
spa |
| dc.relation.none.fl_str_mv |
https://huajsapata.unap.edu.pe/index.php/ria/article/view/55/48 |
| dc.rights.none.fl_str_mv |
Copyright (c) 2020 Revista de Investigaciones Altoandinas info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Copyright (c) 2020 Revista de Investigaciones Altoandinas |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Nacional del Altiplano de Puno |
| publisher.none.fl_str_mv |
Universidad Nacional del Altiplano de Puno |
| dc.source.none.fl_str_mv |
Revista de Investigaciones Altoandinas; Vol. 20 No. 3 (2018); 289-300 Revista de Investigaciones Altoandinas; Vol. 20 Núm. 3 (2018); 289-300 2313-2957 2306-8582 reponame:Revistas Universidad Nacional del Altiplano instname:Universidad Nacional del Altiplano instacron:UNAP |
| reponame_str |
Revistas Universidad Nacional del Altiplano |
| collection |
Revistas Universidad Nacional del Altiplano |
| instname_str |
Universidad Nacional del Altiplano |
| instacron_str |
UNAP |
| institution |
UNAP |
| repository.name.fl_str_mv |
-
|
| repository.mail.fl_str_mv |
mail@mail.com |
| _version_ |
1712974420978434048 |
| spelling |
Thermal comfort in an adobe room with heat storage system in the Andes of PeruConfort térmico en una habitación de adobe con sistema de almacenamiento de calor en los Andes del PerúHolguino Huarza, Antonio Olivera Marocho, LuísEscobar Copa, Katterine Ursula Thermal accumulatorspecific heatthermal conductivityroom with thermal comfortadobe building materialsAcumulador térmicocalor especificohabitación con confort térmicomateriales de construcción de adobeThe objective of this work was the evaluation of thermal comfort inside the test room (HP), of adobe and materials of the high Andean area of Peru, like the andesite stone that is a heat accumulator. This experimental research work determined the values of thermal conductivity 0,176 0,149 and 0,118 W / mK for the adobe, plaster and straw. It was made a comparison was made between the values of thermal conductivity and specific heat, obtained experimentally for the materials and systems used in the construction of HP with the known values of specific materials such as water and air. The design and use of the materials in the construction of the wall, door and window, allowed to determine the values of the thermal conductivities equal to 0,061 0,030 and 0,027 W / mK respectively, that are similar to the thermal conductivity of a natural thermal insulator such as air whose value is 0.026 W / mK. The transfer of heat energy to the outside of the HP, during 11 hours at night is 0,815 MJ. The energy accumulator installed in the HP built with stone, guano and wood whose specific heat values were 1235,13 2416,44 and 2212,77 J / kgK respectively compared with the water, that is a good energy storage, that represent 29,55 57,81 and 52,94% respectively. The HP storage system stores heat energy equivalent to 8,305 MJ, the surplus of heat energy allows that temperature inside HP during the winter times to have average values higher in 63, 83 and 68, 83% at the average temperatures of HC and MAC respectively.El objetivo de este trabajo fue la evaluación del confort térmico al interior de la habitación de prueba (HP) de adobe y materiales de la zona alto andina del Perú, como la piedra andesita que es un acumulador de calor. Esta investigación experimental, determinó los valores de la conductividad térmica 0,176 0,149 y 0,118 W/mK para el adobe, yeso y paja. Se efectuó una comparación entre los valores de la conductividad térmica y calor específico, obtenido experimentalmente para los materiales y sistemas utilizados en la construcción de HP con los valores conocidos de materiales específicos como el agua y el aire. El diseño y uso de los materiales en la construcción de la pared, puerta y ventana, permitieron determinar los valores de las conductividades térmicas iguales a 0,061 0,030 y 0,027 W/mK respectivamente, que son similares a la conductividad térmica de un aislante térmico natural como el aire cuyo valor es 0,026 W/mK. La trasferencia de energía calorífica hacia el exterior de la HP, durante 11 horas nocturnas es 0,815 MJ. El acumulador de energía instalado en la HP construido con piedra, guano y madera cuyos valores del calor específico fueron 1235,13 2416,44 y 2212,77 J/kgK respectivamente; comparada con la del agua que es un buen almacenador de energía, representan 29,55; 57,81 y 52,94 % respectivamente. El sistema acumulador de HP almacena energía calorífica equivalente a 8,305 MJ, el excedente de energía calorífica permite que la temperatura al interior de HP durante las épocas de invierno tenga valores medio mayores en 63,83 y 68,83 % a las temperaturas medias de HC y MAC respectivamente.Universidad Nacional del Altiplano de Puno2018-07-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://huajsapata.unap.edu.pe/index.php/ria/article/view/55Revista de Investigaciones Altoandinas; Vol. 20 No. 3 (2018); 289-300Revista de Investigaciones Altoandinas; Vol. 20 Núm. 3 (2018); 289-3002313-29572306-8582reponame:Revistas Universidad Nacional del Altiplanoinstname:Universidad Nacional del Altiplanoinstacron:UNAPspahttps://huajsapata.unap.edu.pe/index.php/ria/article/view/55/48Copyright (c) 2020 Revista de Investigaciones Altoandinasinfo:eu-repo/semantics/openAccess2021-10-07T15:14:24Zmail@mail.com - |
| score |
13.893769 |
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).