Determination of bacterial contamination in gutta-percha cones in a teaching dental clinic

Descripción del Articulo

Objective: The purpose of this study was to determinate the bacterial contamination of Beta (β) gutta-percha cones at 0, 24, 47 and 72 hours of the different supplies of the Universidad Científica del Sur, Lima 2020. Materials and Methods: 16 β-type gutta-percha cones were obtained of sealed package...

Descripción completa

Detalles Bibliográficos
Autores: Chang Prada, Alberto Andrés, Cabrera Iberico, Miguel, García Rupaya, Carmen Rosa
Formato: artículo
Fecha de Publicación:2020
Institución:Universidad Científica del Sur
Repositorio:Revistas - Universidad Científica del Sur
Lenguaje:español
OAI Identifier:oai:revistas.cientifica.edu.pe:article/694
Enlace del recurso:https://revistas.cientifica.edu.pe/index.php/odontologica/article/view/694
Nivel de acceso:acceso abierto
Materia:microbiología
endodoncia
coagulasa
bacterias gramnegativas
bacterias grampositivas
microbiology
endodontic
coagulase
gram positive bacteria
gram negative bacteria
Descripción
Sumario:Objective: The purpose of this study was to determinate the bacterial contamination of Beta (β) gutta-percha cones at 0, 24, 47 and 72 hours of the different supplies of the Universidad Científica del Sur, Lima 2020. Materials and Methods: 16 β-type gutta-percha cones were obtained of sealed packages under aseptic measurements, they were placed in vials with 2ml BHI and subsequently planted in BHI agar plates as well as in selective medias as Salted mannitol agar and MacConkey agar after 24 hours of incubation at 37 ° the plates were read and  count in CFU , the same procedure was performed for the other times evaluated 24, 48 and 72 hours, giving a total of 64 β-type gutta-percha cones. Results: It was observed that the level of bacterial contamination was the same among the different supplies in all the establish times of in this study 0, 24, 48 and 72 hours. Therefore, there were no significant differences in the level of bacterial contamination between the supplies. On the other hand, only statistically significant differences (p.044) were found between the different times of the supply number 5. Finally, all the samples submitted to the coagulase test had a negative result. Conclusion: The gutta-percha cones of type β were contaminated equally regardless of the supply in which they were stored or manipulated.
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).