Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
Descripción del Articulo
        There are no methods in our town to determine Ti (IV) in samples. In this work we used an electrochemical sensitive method to determine Ti (IV). It is based on formation of a complex with cupferron in acid solution. The analysis was made in a voltamperomnietric station equipped with a drop mercury e...
              
            
    
                        | Autores: | , | 
|---|---|
| Formato: | artículo | 
| Fecha de Publicación: | 2019 | 
| Institución: | Universidad Católica de Santa María | 
| Repositorio: | Revistas - Universidad Católica de Santa María | 
| Lenguaje: | español | 
| OAI Identifier: | oai:ojs.revistas.ucsm.edu.pe:article/198 | 
| Enlace del recurso: | https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198 | 
| Nivel de acceso: | acceso abierto | 
| Materia: | Titanio cupferrón voltamperometría | 
| id | REVUCSM_fb807133cdb22a45f071a7cd8a76f712 | 
|---|---|
| oai_identifier_str | oai:ojs.revistas.ucsm.edu.pe:article/198 | 
| network_acronym_str | REVUCSM | 
| network_name_str | Revistas - Universidad Católica de Santa María | 
| repository_id_str |  | 
| spelling | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste Estandarización de una técnica electroquímica para la determinación de titanio en muestras de productos farmacéuticos y residuos industrialesJeaneth Marisol Medina PérezJosé Antonio Villanueva SalasTitaniocupferrónvoltamperometríaThere are no methods in our town to determine Ti (IV) in samples. In this work we used an electrochemical sensitive method to determine Ti (IV). It is based on formation of a complex with cupferron in acid solution. The analysis was made in a voltamperomnietric station equipped with a drop mercury electrode (HMDE) a reference electrode Ag/AgCl and an auxiliary platinum electrode. A buffer of ammonium acetate pH 5 and a solution of cupferron 1x10^-3 mol.dm3. The peak resulting from complex formation is proportional to concentration of Ti (IV) . the detection limit was 7 mg.L^-1 obtained under optimal experimental conditions . This method showed to be linear, exact and reproducible and was applied for determination of Ti (IV) in environmental samples and pharmaceutical products giving satisfactory resultsEn nuestro medio no existen métodos para la determinación de Ti (IV) en diferentes muestras, por lo que en el presente trabajo un método electroquímico sensible para la determinación de Ti (1V) fue ensayado, basado en la formación de complejo de Ti (IV) con cupferrón en solución ácida. El análisis se realizó en una estación voltamperométrica e.z1uipada con un electrodo de gota colgante de mercurio (HMDE), un electrodo de referencia de Ag/AgCl y un electrodo auxiliar de platino. Se usó un buffer acetato de amonio de pH 5.6 y una solución de cupferrón 1x10^-3 mol.dm3. El pico máximo resultante de la formación del complejo es proporcional a la concentración de Ti (IV) El límite de detección fue de 7 mg.L^-1 obtenido bajo condiciones experimentales óptimas. El método mostró ser lineal, exacto y reproducible y fue aplicado para la determinación de Ti (IV) en muestras ambientales y productos farmacéuticos con resultados satisfactorios.Universidad Católica de Santa María2019-06-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-1991684-78221684-782210.35286/veritas.v13i1reponame:Revistas - Universidad Católica de Santa Maríainstname:Universidad Católica de Santa Maríainstacron:UCSMspahttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198/123Derechos de autor 2019 Veritasinfo:eu-repo/semantics/openAccessoai:ojs.revistas.ucsm.edu.pe:article/1982019-06-11T17:57:25Z | 
| dc.title.none.fl_str_mv | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste Estandarización de una técnica electroquímica para la determinación de titanio en muestras de productos farmacéuticos y residuos industriales | 
| title | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste | 
| spellingShingle | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste Jeaneth Marisol Medina Pérez Titanio cupferrón voltamperometría | 
| title_short | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste | 
| title_full | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste | 
| title_fullStr | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste | 
| title_full_unstemmed | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste | 
| title_sort | Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste | 
| dc.creator.none.fl_str_mv | Jeaneth Marisol Medina Pérez José Antonio Villanueva Salas | 
| author | Jeaneth Marisol Medina Pérez | 
| author_facet | Jeaneth Marisol Medina Pérez José Antonio Villanueva Salas | 
| author_role | author | 
| author2 | José Antonio Villanueva Salas | 
| author2_role | author | 
| dc.subject.none.fl_str_mv | Titanio cupferrón voltamperometría | 
| topic | Titanio cupferrón voltamperometría | 
| description | There are no methods in our town to determine Ti (IV) in samples. In this work we used an electrochemical sensitive method to determine Ti (IV). It is based on formation of a complex with cupferron in acid solution. The analysis was made in a voltamperomnietric station equipped with a drop mercury electrode (HMDE) a reference electrode Ag/AgCl and an auxiliary platinum electrode. A buffer of ammonium acetate pH 5 and a solution of cupferron 1x10^-3 mol.dm3. The peak resulting from complex formation is proportional to concentration of Ti (IV) . the detection limit was 7 mg.L^-1 obtained under optimal experimental conditions . This method showed to be linear, exact and reproducible and was applied for determination of Ti (IV) in environmental samples and pharmaceutical products giving satisfactory results | 
| publishDate | 2019 | 
| dc.date.none.fl_str_mv | 2019-06-11 | 
| dc.type.none.fl_str_mv | info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion | 
| format | article | 
| status_str | publishedVersion | 
| dc.identifier.none.fl_str_mv | https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198 | 
| url | https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198 | 
| dc.language.none.fl_str_mv | spa | 
| language | spa | 
| dc.relation.none.fl_str_mv | https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198/123 | 
| dc.rights.none.fl_str_mv | Derechos de autor 2019 Veritas info:eu-repo/semantics/openAccess | 
| rights_invalid_str_mv | Derechos de autor 2019 Veritas | 
| eu_rights_str_mv | openAccess | 
| dc.format.none.fl_str_mv | application/pdf | 
| dc.publisher.none.fl_str_mv | Universidad Católica de Santa María | 
| publisher.none.fl_str_mv | Universidad Católica de Santa María | 
| dc.source.none.fl_str_mv | Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199 Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199 Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199 1684-7822 1684-7822 10.35286/veritas.v13i1 reponame:Revistas - Universidad Católica de Santa María instname:Universidad Católica de Santa María instacron:UCSM | 
| instname_str | Universidad Católica de Santa María | 
| instacron_str | UCSM | 
| institution | UCSM | 
| reponame_str | Revistas - Universidad Católica de Santa María | 
| collection | Revistas - Universidad Católica de Santa María | 
| repository.name.fl_str_mv |  | 
| repository.mail.fl_str_mv |  | 
| _version_ | 1847332599263920128 | 
| score | 13.073869 | 
 Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
    La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
 
   
   
             
            