Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste

Descripción del Articulo

There are no methods in our town to determine Ti (IV) in samples. In this work we used an electrochemical sensitive method to determine Ti (IV). It is based on formation of a complex with cupferron in acid solution. The analysis was made in a voltamperomnietric station equipped with a drop mercury e...

Descripción completa

Detalles Bibliográficos
Autores: Jeaneth Marisol Medina Pérez, José Antonio Villanueva Salas
Formato: artículo
Fecha de Publicación:2019
Institución:Universidad Católica de Santa María
Repositorio:Revistas - Universidad Católica de Santa María
Lenguaje:español
OAI Identifier:oai:ojs.revistas.ucsm.edu.pe:article/198
Enlace del recurso:https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198
Nivel de acceso:acceso abierto
Materia:Titanio
cupferrón
voltamperometría
id REVUCSM_fb807133cdb22a45f071a7cd8a76f712
oai_identifier_str oai:ojs.revistas.ucsm.edu.pe:article/198
network_acronym_str REVUCSM
network_name_str Revistas - Universidad Católica de Santa María
repository_id_str
spelling Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste Estandarización de una técnica electroquímica para la determinación de titanio en muestras de productos farmacéuticos y residuos industrialesJeaneth Marisol Medina PérezJosé Antonio Villanueva SalasTitaniocupferrónvoltamperometríaThere are no methods in our town to determine Ti (IV) in samples. In this work we used an electrochemical sensitive method to determine Ti (IV). It is based on formation of a complex with cupferron in acid solution. The analysis was made in a voltamperomnietric station equipped with a drop mercury electrode (HMDE) a reference electrode Ag/AgCl and an auxiliary platinum electrode. A buffer of ammonium acetate pH 5 and a solution of cupferron 1x10^-3 mol.dm3. The peak resulting from complex formation is proportional to concentration of Ti (IV) . the detection limit was 7 mg.L^-1 obtained under optimal experimental conditions . This method showed to be linear, exact and reproducible and was applied for determination of Ti (IV) in environmental samples and pharmaceutical products giving satisfactory resultsEn nuestro medio no existen métodos para la determinación de Ti (IV) en diferentes muestras, por lo que en el presente trabajo un método electroquímico sensible para la determinación de Ti (1V) fue ensayado, basado en la formación de complejo de Ti (IV) con cupferrón en solución ácida. El análisis se realizó en una estación voltamperométrica e.z1uipada con un electrodo de gota colgante de mercurio (HMDE), un electrodo de referencia de Ag/AgCl y un electrodo auxiliar de platino. Se usó un buffer acetato de amonio de pH 5.6 y una solución de cupferrón 1x10^-3 mol.dm3. El pico máximo resultante de la formación del complejo es proporcional a la concentración de Ti (IV) El límite de detección fue de 7 mg.L^-1 obtenido bajo condiciones experimentales óptimas. El método mostró ser lineal, exacto y reproducible y fue aplicado para la determinación de Ti (IV) en muestras ambientales y productos farmacéuticos con resultados satisfactorios.Universidad Católica de Santa María2019-06-11info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-1991684-78221684-782210.35286/veritas.v13i1reponame:Revistas - Universidad Católica de Santa Maríainstname:Universidad Católica de Santa Maríainstacron:UCSMspahttps://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198/123Derechos de autor 2019 Veritasinfo:eu-repo/semantics/openAccessoai:ojs.revistas.ucsm.edu.pe:article/1982019-06-11T17:57:25Z
dc.title.none.fl_str_mv Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
Estandarización de una técnica electroquímica para la determinación de titanio en muestras de productos farmacéuticos y residuos industriales

title Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
spellingShingle Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
Jeaneth Marisol Medina Pérez
Titanio
cupferrón
voltamperometría
title_short Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
title_full Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
title_fullStr Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
title_full_unstemmed Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
title_sort Standardization of electrochemical technique for the determination of titanium in samples of pharmaceuticals and industrial waste
dc.creator.none.fl_str_mv Jeaneth Marisol Medina Pérez
José Antonio Villanueva Salas
author Jeaneth Marisol Medina Pérez
author_facet Jeaneth Marisol Medina Pérez
José Antonio Villanueva Salas
author_role author
author2 José Antonio Villanueva Salas
author2_role author
dc.subject.none.fl_str_mv Titanio
cupferrón
voltamperometría
topic Titanio
cupferrón
voltamperometría
description There are no methods in our town to determine Ti (IV) in samples. In this work we used an electrochemical sensitive method to determine Ti (IV). It is based on formation of a complex with cupferron in acid solution. The analysis was made in a voltamperomnietric station equipped with a drop mercury electrode (HMDE) a reference electrode Ag/AgCl and an auxiliary platinum electrode. A buffer of ammonium acetate pH 5 and a solution of cupferron 1x10^-3 mol.dm3. The peak resulting from complex formation is proportional to concentration of Ti (IV) . the detection limit was 7 mg.L^-1 obtained under optimal experimental conditions . This method showed to be linear, exact and reproducible and was applied for determination of Ti (IV) in environmental samples and pharmaceutical products giving satisfactory results
publishDate 2019
dc.date.none.fl_str_mv 2019-06-11
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198
url https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv https://revistas.ucsm.edu.pe/ojs/index.php/veritas/article/view/198/123
dc.rights.none.fl_str_mv Derechos de autor 2019 Veritas
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Derechos de autor 2019 Veritas
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Católica de Santa María
publisher.none.fl_str_mv Universidad Católica de Santa María
dc.source.none.fl_str_mv Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199
Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199
Veritas; Vol. 13 Núm. 1 (2011): VÉRITAS: Investigación, Innovación y Desarrollo; 194-199
1684-7822
1684-7822
10.35286/veritas.v13i1
reponame:Revistas - Universidad Católica de Santa María
instname:Universidad Católica de Santa María
instacron:UCSM
instname_str Universidad Católica de Santa María
instacron_str UCSM
institution UCSM
reponame_str Revistas - Universidad Católica de Santa María
collection Revistas - Universidad Católica de Santa María
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1847332599263920128
score 13.073869
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).