KINETICS STUDY OF CADMIUM (II) BIOSORPTION ON CROSSLINKED PECTIN FROM ORANGE PEELS
Descripción del Articulo
Biosorption kinetics of cadmium (II) on cross-linked pectin extracted from orange peels at 20°C was studied, obtaining an equilibrium sorption capacity, q , of 99.56 mg/g in pH range e 4.5-5.5. Pectic material was extracted through acid hydrolysis (pH: 1.5, temperature: 90°C, time: 30 min) and cross...
Autores: | , , , , , |
---|---|
Formato: | artículo |
Fecha de Publicación: | 2014 |
Institución: | Sociedad Química del Perú |
Repositorio: | Revista de la Sociedad Química del Perú |
Lenguaje: | español |
OAI Identifier: | oai:rsqp.revistas.sqperu.org.pe:article/183 |
Enlace del recurso: | http://revistas.sqperu.org.pe/index.php/revistasqperu/article/view/183 |
Nivel de acceso: | acceso abierto |
Materia: | Biosorption pectin cadmium kinetic pseudo-first order pseudo-second order Biosorción pectina cadmio cenética peseudo-primer orden pesudo-segundo orden |
Sumario: | Biosorption kinetics of cadmium (II) on cross-linked pectin extracted from orange peels at 20°C was studied, obtaining an equilibrium sorption capacity, q , of 99.56 mg/g in pH range e 4.5-5.5. Pectic material was extracted through acid hydrolysis (pH: 1.5, temperature: 90°C, time: 30 min) and crosslinked with formaldehyde acidic solution in order to diminish hydration capacity and swelling, as well as polysaccharide leaching when found in aqueous environment. Biosorption kinetics experimental data showed greater coefficients of correlation (R ) on pseudo second order mathematic model. Physical chemistry parameters: particle size influence (125 µm - 500 µm and 0 µm - 125 µm) and biosorbent and metal concentrations in solution were evaluated in the biosorption kinetics. Pseudo second order -4 -1 -1 constant, k = 8.0x10 g.mg min , of biosorbent with particle size 125-500 µm increased in 2 13.7% as particle size decreased to 0-125 µm, meanwhile, q increased from 140.7 to 148.4 e mg/g at the same conditions. Lead (II) residual concentrations in solution were determined by atomic absorption spectroscopy. For data processing and statistic treatment of non-linear regression, Origin 6.0 informatics program was used. |
---|
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).