Evaluation of male factor in assisted reproduction: new technologies

Descripción del Articulo

Objectives: To determine whether volumetric ultrasonography (3D, static and dynamic) provides better information than conventional ultrasound (2D) in the assessment of pregnancy before 7 weeks of amenorrhea. Design: Clinical series of cases study. Setting: Instituto Latinoamericano de Salud Reproduc...

Descripción completa

Detalles Bibliográficos
Autores: Huamán Guerrero, Moisés, Huamán Joo, Moisés, Arias Rayo, J.
Formato: artículo
Fecha de Publicación:2015
Institución:Sociedad Peruana de Obstetricia y Ginecología
Repositorio:Revista Peruana de Ginecología y Obstetricia
Lenguaje:español
OAI Identifier:oai:ojs.pkp.sfu.ca:article/202
Enlace del recurso:http://51.222.106.123/index.php/RPGO/article/view/202
Nivel de acceso:acceso abierto
id REVSPOG_93b09d47d3f7a0aa3ca5341af5dfc2c5
oai_identifier_str oai:ojs.pkp.sfu.ca:article/202
network_acronym_str REVSPOG
network_name_str Revista Peruana de Ginecología y Obstetricia
repository_id_str .
dc.title.none.fl_str_mv Evaluation of male factor in assisted reproduction: new technologies
Ecografía 2D y volumétrica (3D/4D) en el embrión de 5 y 7 semanas
title Evaluation of male factor in assisted reproduction: new technologies
spellingShingle Evaluation of male factor in assisted reproduction: new technologies
Huamán Guerrero, Moisés
title_short Evaluation of male factor in assisted reproduction: new technologies
title_full Evaluation of male factor in assisted reproduction: new technologies
title_fullStr Evaluation of male factor in assisted reproduction: new technologies
title_full_unstemmed Evaluation of male factor in assisted reproduction: new technologies
title_sort Evaluation of male factor in assisted reproduction: new technologies
dc.creator.none.fl_str_mv Huamán Guerrero, Moisés
Huamán Joo, Moisés
Arias Rayo, J.
author Huamán Guerrero, Moisés
author_facet Huamán Guerrero, Moisés
Huamán Joo, Moisés
Arias Rayo, J.
author_role author
author2 Huamán Joo, Moisés
Arias Rayo, J.
author2_role author
author
description Objectives: To determine whether volumetric ultrasonography (3D, static and dynamic) provides better information than conventional ultrasound (2D) in the assessment of pregnancy before 7 weeks of amenorrhea. Design: Clinical series of cases study. Setting: Instituto Latinoamericano de Salud Reproductiva – ILSAR. Participants: Pregnant women within the fifth and seventh weeks of pregnancy. Interventions: An endovaginal ultrasound was performed to 30 pregnant women between the fifth and seventh weeks of amenorrhea with a GE Volusson Expert 730 using multifrequency endocavitary transductor (3.7-9.3 MHZ), 75% maximum potency in function ‘Early Pregnancy’ without harmonics; test duration was 5-15 minutes. Once the chorionic sac was localized its content was assessed for the yolk sac and the embryo, first using 2D and then static 3D and dynamic 3D (4D). Main outcome measures: Identification of the yolk sac and the embryo. Results: The yolk sac could be identified using 3D ultrasound in 7 pregnant women with less than 5 weeks and 3 days of gestation, preceding its obsevation with 2D ultrasound  by 3 to 4 days average. Assessment of the embryo before 6 weeks of gestation could be done in 12 pregnancies using 3D ultrasound. Multiplanar technic enhanced sensitivity to detect the embryo earlier. Assessment of the yolk sac, omphalomesenteric duct and embryo in gestations between 6 and 7 weeks was better accomplished with 3D. Conclusions: The use of volumetric ultrasonography (3D/4D) in early pregnancy allowed the identification of the yolk sac and embryo 3 to 4 days before 2D ultrasonography, representing an improvement in interpreting visible structures by obstetricians and parents.
publishDate 2015
dc.date.none.fl_str_mv 2015-04-19
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://51.222.106.123/index.php/RPGO/article/view/202
url http://51.222.106.123/index.php/RPGO/article/view/202
dc.language.none.fl_str_mv spa
language spa
dc.relation.none.fl_str_mv http://51.222.106.123/index.php/RPGO/article/view/202/181
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
publisher.none.fl_str_mv Sociedad Peruana de Obstetricia y Ginecología
dc.source.none.fl_str_mv The Peruvian Journal of Gynecology and Obstetrics ; Vol. 57 No. 1 (2011); 29-32
Revista Peruana de Ginecología y Obstetricia; Vol. 57 Núm. 1 (2011); 29-32
2304-5132
2304-5124
reponame:Revista Peruana de Ginecología y Obstetricia
instname:Sociedad Peruana de Obstetricia y Ginecología
instacron:SPOG
instname_str Sociedad Peruana de Obstetricia y Ginecología
instacron_str SPOG
institution SPOG
reponame_str Revista Peruana de Ginecología y Obstetricia
collection Revista Peruana de Ginecología y Obstetricia
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1842711548403908608
spelling Evaluation of male factor in assisted reproduction: new technologiesEcografía 2D y volumétrica (3D/4D) en el embrión de 5 y 7 semanasHuamán Guerrero, MoisésHuamán Joo, MoisésArias Rayo, J.Objectives: To determine whether volumetric ultrasonography (3D, static and dynamic) provides better information than conventional ultrasound (2D) in the assessment of pregnancy before 7 weeks of amenorrhea. Design: Clinical series of cases study. Setting: Instituto Latinoamericano de Salud Reproductiva – ILSAR. Participants: Pregnant women within the fifth and seventh weeks of pregnancy. Interventions: An endovaginal ultrasound was performed to 30 pregnant women between the fifth and seventh weeks of amenorrhea with a GE Volusson Expert 730 using multifrequency endocavitary transductor (3.7-9.3 MHZ), 75% maximum potency in function ‘Early Pregnancy’ without harmonics; test duration was 5-15 minutes. Once the chorionic sac was localized its content was assessed for the yolk sac and the embryo, first using 2D and then static 3D and dynamic 3D (4D). Main outcome measures: Identification of the yolk sac and the embryo. Results: The yolk sac could be identified using 3D ultrasound in 7 pregnant women with less than 5 weeks and 3 days of gestation, preceding its obsevation with 2D ultrasound  by 3 to 4 days average. Assessment of the embryo before 6 weeks of gestation could be done in 12 pregnancies using 3D ultrasound. Multiplanar technic enhanced sensitivity to detect the embryo earlier. Assessment of the yolk sac, omphalomesenteric duct and embryo in gestations between 6 and 7 weeks was better accomplished with 3D. Conclusions: The use of volumetric ultrasonography (3D/4D) in early pregnancy allowed the identification of the yolk sac and embryo 3 to 4 days before 2D ultrasonography, representing an improvement in interpreting visible structures by obstetricians and parents.Objetivos: Determinar si la ecografía volumétrica (3D estática y 4D dinámica) aporta mejor información que la ecografía convencional (2D), en el estudio del embarazo antes de las 7 semanas de amenorrea. Diseño: Estudio clínico serie de casos. Institución: Instituto Latinoamericano de Salud Reproductiva – ILSAR. Participantes: Gestantes, entre la quinta y séptima semana de embarazo. Intervenciones: Se evaluó por ecografía endovaginal a 30 gestantes, entre la quinta y séptima semana, con régimen catameneal seguro y evolución normal. Se utilizó un equipo GE modelo Voluson 730-Expert, con una sonda endocavitaria multifrecuencia (3,7-9,3 MHZ), potencia máxima de 75%, en la función de ‘embarazo temprano’; no se utilizó armónicas; tiempo de exposición total entre 5 y 15 minutos. Ubicado el saco coriónico, se evaluó su contenido, buscando la vesícula vitelínica y el embrión, primero con 2D y luego con 3D estático y dinámico (4D). El control fue entre los 3 y 4 días en la quinta semana, y una vez a la sexta y séptima semana. Principales medidas de resultados: Visualización del saco vitelino y el embrión. Resultados: En 7 embarazos menores de 5 semanas y 3 días, en los que no se observó vesícula vitelínica con la ecografía 2D, pudo identificarse esta estructura con la ecografía 3D, adelantando su observación 3 a 4 días en promedio. En 12 embarazos menores de 6 semanas en los que se veía vesícula vitelínica pero no el embrión con ecografía 2D, se logró identificarlo satisfactoriamente con la ecografía 3D, adelantando la observación del embrión por 3 a 4 días, presentando mejor performance el estudio multiplanar. En las pacientes que cursaban entre 6 y 7 semanas de gestación, la ecografía 3D evidenció mejor la morfología de la vesícula vitelínica, el conducto onfalomesentérico y del embrión, así como los movimientos segmentarios iniciales del embrión. Conclusiones: La ecografía volumétrica (3D/4D) permite identificar la vesícula vitelínica y el embrión 3 a 4 días antes que con la ecografía 2D endovaginal. Las imágenes volumétricas mejoran la interpretación de las estructuras embrionarias, tanto por el examinador como por los padres; por tanto, adicionan información a la ecografía convencional.Sociedad Peruana de Obstetricia y Ginecología2015-04-19info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://51.222.106.123/index.php/RPGO/article/view/202The Peruvian Journal of Gynecology and Obstetrics ; Vol. 57 No. 1 (2011); 29-32Revista Peruana de Ginecología y Obstetricia; Vol. 57 Núm. 1 (2011); 29-322304-51322304-5124reponame:Revista Peruana de Ginecología y Obstetriciainstname:Sociedad Peruana de Obstetricia y Ginecologíainstacron:SPOGspahttp://51.222.106.123/index.php/RPGO/article/view/202/181info:eu-repo/semantics/openAccessoai:ojs.pkp.sfu.ca:article/2022015-08-04T23:33:32Z
score 12.660673
Nota importante:
La información contenida en este registro es de entera responsabilidad de la institución que gestiona el repositorio institucional donde esta contenido este documento o set de datos. El CONCYTEC no se hace responsable por los contenidos (publicaciones y/o datos) accesibles a través del Repositorio Nacional Digital de Ciencia, Tecnología e Innovación de Acceso Abierto (ALICIA).